BondMaster 600
8Pages

{{requestButtons}}

Catalog excerpts

BondMaster 600 - 1

Composite Bond Tester High signal quality • Multiple modes • Application presets • Full-screen display • Complete archiving and reporting solution

Open the catalog to page 1
BondMaster 600 - 2

BondMaster® 600 Multimode Bond Tester High Performance Through Intuitive Operation The BondMaster® 600 bond tester delivers a powerful combination of multiple mode bond testing software and highly advanced electronics, providing consistently crisp and high-quality signals. Whether you are inspecting honeycomb composite, metal-to-metal bonds, or laminate composite, the BondMaster 600 bond tester offers exceptional ease-of-use thanks to its direct-access keys and a streamlined interface that features convenient presets for common applications. The instrument’s enhanced user interface and...

Open the catalog to page 2
BondMaster 600 - 3

Simplified Interface and Vibrant Display Instant Configuration and Direct Access to All Settings One of the major assets of the BondMaster® 600 bond tester is its ease of use. Its streamlined and user-friendly interface was developed by incorporating innovative features from other Olympus products and combining them with several new functions, including the application selection (presets) menu, the all settings direct modification screen, and the ability to calibrate signals while in freeze mode. All the advantages offered by the BondMaster 600 interface are available in 15 languages. The...

Open the catalog to page 3
BondMaster 600 - 4

Outstanding Signal Quality Enhance Your Honeycomb Composite Inspection Capability During bond testing inspections, the pitch-catch probe produces flexural plate waves and compression waves and compares changes in the signal amplitude between the probe’s transmitter and receiver as it passes over the inspected part, detecting disbonds on both the near and far side. The BondMaster® 600 bond tester offers three pitch-catch mode options: RF (fixed frequency waveform), impulse (legacy view featuring an envelope filter), or swept (sweeping through a selected frequency range). The instrument’s...

Open the catalog to page 4
BondMaster 600 - 5

Resonance Mode Presets to Meet Your Needs Easy Inspection of Metal-to-Metal Bonds and Laminate Composites Resonance mode measures the changes in phase and amplitude of the propagating/standing wave within the probe. Resonance probes are narrow bandwidth contact transducers, and the change in probe crystal impedance is represented in the X-Y instrument's display. Resonance mode is a very simple and reliable way to detect delamination. Often, the depth of delamination can be estimated from signal phase rotation. Resonance mode on the BondMaster® 600 bond tester is remarkably easy to operate,...

Open the catalog to page 5
BondMaster 600 - 6

Witness the Power and Precision of MIA Mode Detect Small Disbonds in Honeycomb Composite The bond testing mechanical impedance analysis (MIA) method measures the mechanical impedance, or stiffness, of a material. MIA probes emit a fixed, audible frequency. Changes in material stiffness are indicated as signal amplitude and phase changes in the X-Y view of the BondMaster® 600 bond tester. The small probe tip used with MIA, coupled with the high-performance electronics of the BondMaster 600 bond tester, make detecting very small disbonds in honeycomb composite much easier than with other...

Open the catalog to page 6
BondMaster 600 - 7

Complete Inspection, Archiving, and Reporting Solution Simplified Workflow for Any Level of User The BondMaster® 600 bond tester offers a streamlined and straightforward process for tracking your inspection results. Built-in features such as a large storage capacity (up to 500 data and program files) and an onboard file preview facilitate the inspection process, from start to finish. A typical workflow consists of a few simple steps: save your results during the inspection process, download the saved files to the BondMaster PC viewing software, instantly generate a full inspection report...

Open the catalog to page 7
BondMaster 600 - 8

For a complete specifications list, please download the full BondMaster® 600 user’s manual at www.olympus-ims.com. General Overall Dimensions (W x H x D) Weight Power Requirements 236 mm x 167 mm x 70 mm (9.3 in. x 6.57 in. x 2.76 in.) 1.70 kg (3.75 lb), including lithium-ion battery Mil Standard 810G, CE, WEEE, FCC (USA), IC (Canada), RoHS (China), RCM (Australia and New Zealand), KCC (South Korea) A version that conforms to the requirements of the ATEX directive is available.** For more information, visit us online at www.olympus-ossa.com. AC Mains: 100 VAC to 120 VAC, 200 VAC to 240 VAC,...

Open the catalog to page 8

All Evident - Olympus Scientific Solutions catalogs and technical brochures

  1. 72DL PLUS™

    8 Pages

  2. DC1–DC5

    5 Pages

  3. 45MG

    12 Pages

  4. 35 RDC

    2 Pages

  5. IPLEX GX/GT

    8 Pages

  6. IPLEX TX

    4 Pages

  7. IPLEX G Lite

    8 Pages

  8. IPLEX GAir

    8 Pages

  9. IPLEX NX

    12 Pages

  10. OLYMPUS Stream

    16 Pages

  11. LC35

    4 Pages

  12. DP74

    8 Pages

  13. DP28

    8 Pages

  14. SZX7

    16 Pages

  15. SZX16 - SZX10

    24 Pages

  16. MX63/MX63L

    20 Pages

  17. GX53 Brochure

    20 Pages

  18. CIX100

    16 Pages

  19. STM7 Series

    24 Pages

  20. LEXT OLS5000

    42 Pages

  21. 38DL PLUS

    12 Pages

  22. NORTEC 600

    7 Pages

  23. 72DL PLUS

    8 Pages

  24. SZX-AR1

    12 Pages

  25. 27MG

    4 Pages

  26. EdgeFORM™

    2 Pages

  27. OpenView SDK

    3 Pages

  28. OmniScan MX

    12 Pages