Overview: This document provides technical specifications and performance data for OLEOWEB's hydraulic valves, specifically the SAE8 double sealing electric valves. It highlights the company's right to modify product details without prior notice.
Performance Tests: Tests were conducted with solenoids at their working temperature, using a supply voltage 10% below the nominal value.
Technical Specifications:
  • Type: ED082A-CNP
  • Max Flow: 22 l/min (5.8 USgpm)
  • Max Pressure: 210 bar (3045 PSI)
  • Approx Weight: 0.13 kg (0.28 lbs)
  • Tightening Torque: 30 Nm (22 lbt ft)
  • Cavity: 3/4-16UNF-2A
Hydraulic Circuit: The valve is normally closed with an emergency function.
Technical Characteristics:
  • Hydraulic Oil: Mineral oil ISO 6743/4 (DIN 51524)
  • Oil Viscosity: 15-250 mm2/s (15 to 250 cSt)
  • Max Contamination Index: ISO 4406:1999 Class 18/16/13
  • Oil Temperature: -20°C to +80°C (-4°F to +176°F)
  • Environment Temperature: -20°C to +50°C (-4°F to +122°F)
  • Recommended Filtration: 15 μm
  • Max Leakage: 0.25 cm3/min (5 drops/min)
Additional Information: A 22 W coil and connector are required, with further details available on pages 102-103.
See more

Catalog excerpts

ED082A-1

VALVOLE A COMANDO ELETTRICO SAE8 DOPPIA TENUTA 2 VIE/2 POSIZIONI DIRETTE 2 WAYS/2 POSITIONS SAE8 DOUBLE SEALING ELECTRIC VALVES - DIRECT ACTING VALVES & SOLUTIONS CODICE ORDINAZIONE ORDERING CODE VALVOLE A COMANDO ELETTRICO SAE8 DOPPIA TENUTA 2 VIE/2 POSIZIONI DIRETTE (2 WAYS/2 POSITIONS SAE8 DOUBLE SEALING ELECTRIC VALVES - DIRECT ACTING) SCHEMA Normalmente chiusa + emergenza (Normally closed + emergency) SCHEMA IDRAULICO / HYDRAULIC CIRCUIT 1 DATI TECNICI / TECHNICAL DATA Olio idraulico - Mineral oil Viscosità olio - Oil viscosity Classe di contaminazione max Max contamination index Temperatura dell'olio - Oil temperature Temperatura ambiente - Environment temperature -20°C +50°C È indispensabile l’utilizzo di un filtro per proteggere la valvola (filtrazione consigliata 15 μm) It is necessary a filter use to protect the valve (advised filtration 15 μm) Trafilamento massimo Max leakage BOBINA 22 W E CONNETTORE VEDI PG. 102-103 Le prove sono state eseguite con solenoidi a temperatura di regime, sottoalimentati del 10% rispetto al valore nominale. Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value. CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS TIPO TYPE PORTATA MAX (l/min) MAX FLOW (USgpm) PESO APPROX (kg) APPROX WEIGHT (lbt) COPPIA DI SERRAGGIO TIGHTENING TORQUE Nm-lbt ft CAVITÀ CAVITY I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso. OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change. Aggiornamento - Update

 Open the catalog to page 1

All Oleoweb Srl catalogs and technical brochures

  1. EC082C

    1  Page

  2. EC082B

    1  Page

  3. EC082A

    1  Page

  4. VBCD

    1  Page

  5. VBLF

    1  Page

  6. VCLH

    1  Page

  7. VCCR

    1  Page

  8. VBCL-SAE

    1  Page

  9. VBCB

    1  Page

  10. VMF-H

    1  Page

  11. VMF-BSPP

    1  Page

  12. VUR-SAE

    1  Page

  13. VUR-H

    1  Page

  14. VUR

    1  Page

  15. VUBA

    1  Page

  16. VUP

    1  Page

  17. VUC

    1  Page

  18. RAS4-NPT

    1  Page

  19. VBCL

    1  Page

  20. VPR22

    1  Page

  21. SCVB

    1  Page

  22. VUI

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.