Introduction
The document discusses the benefits of using INVERTER systems with semi-hermetic motor compressors in refrigeration applications. Key advantages include energy savings, increased compressor reliability, reduced transient conditions, and noise reduction. The use of soft start inverters is recommended, particularly for supermarket refrigeration systems.

Complete Range
DORIN has developed a series of semi-hermetic compressors suitable for INVERTER applications, operating between 20Hz and 90Hz. These compressors, based on the H11, H35, and H41 series, are known for high C.O.P. values, low vibration, and pressure pulsation reduction. They feature an IP55 electric box, motor thermal protection, and parallel connection capability.

Application Limits
The document outlines operational limits for refrigerants such as R134a, R404A/R507, R407F/R407A, and R407C, providing specific performance data for each.

Performance Data
Performance data is provided for various refrigerants, detailing the efficiency and operational parameters of the compressors when used with INVERTER technology.

Overall Dimensions
Information on the physical dimensions of the compressors is included to ensure compatibility with existing systems and installations.

Test Results
A comparison test between systems with and without INVERTER technology shows significant energy savings, increased reliability, reduced transient conditions, and noise reduction. The test involved two systems, one for low temperature and one for medium temperature, both equipped with DORIN compressors.

Overview
Dorin has developed a range of semi-hermetic compressors designed to work with frequency converter technologies, operating over a wide frequency range from 20Hz to 90Hz due to a special design of the rolling parts.

Specifications
The compressors are similar to the previously tested H11, H35, and H41 series, maintaining high COP values, reduced vibration, and pulsation phenomena. They feature IP55 electrical enclosures, motor thermal protection using thermistors or Thermik, and can operate in parallel. Additionally, they have a specific electric motor for frequency converters and can operate from 20Hz to 90Hz due to a kinetic accumulator (patent pending).

Technical Characteristics
The document provides detailed technical data for various models, including displacement volume, net weight, and operating currents. The maximum allowable frequency is 75Hz, and the exact operating limits for each model should be referred to in the Dorin selection software.

Performance Data
Performance data is based on the European Standard EN12900. It is advised never to mix ester oils with different oils. The document includes performance data for different refrigerants like R134a, R407C, and R404A/R507, with tables showing power consumption and cooling capacity at various temperatures and frequencies.

Application Limits
The document outlines the application limits for different refrigerants, with graphs showing the relationship between evaporation and condensing temperatures. It also provides guidelines for standard operation and conditions requiring head cooling fans or maximum superheating.

Specifications
The document provides performance data for refrigeration systems using refrigerants R404A, R507, R407F, and R407A. The data is based on the European Standard EN12900. It includes tables of power input (P) in kW and refrigerating capacity (Q) in W across various evaporating temperatures ranging from +10°C to -40°C.

Procedures
It is emphasized that ester oils should never be mixed with different oils. For systems using R407A, a 6% reduction in both Q and P should be considered while maintaining the same Coefficient of Performance (COP).

Norms
The performance data adheres to the European Standard EN12900, ensuring consistency and reliability in the measurements provided.

Recommendations
Users are advised to strictly follow the guidelines regarding oil mixing and to adjust performance expectations when using R407A refrigerant.

Data Summary
The document includes extensive tables showing the relationship between power input and refrigerating capacity at different temperatures and frequencies. Key data points include:
  • At +5°C, Q ranges from 2710 W to 53150 W, and P ranges from 0.61 kW to 14.46 kW.
  • At -40°C, Q ranges from 190 W to 6250 W, and P ranges from 0.22 kW to 5.61 kW.
See more

Catalog excerpts

HI RANGE for inverter use-1

HISERIES INVERTER SEMI-HERMETIC MOTOR COMPRESSORS MOTOCOMPRESSORISEMIERMETICI MOTO-COMPRESSEURS SEMI-HERMETIQUES HALBHERMETISCHE VERDICHTER

 Open the catalog to page 1
HI RANGE for inverter use-2

INDICE / TABLE OF CONTENTS / INDEX / INHALTSVERZEICHNIS ____________________________________________________________________________________________________________________________________________ Introduzione / Introduction / Introduction / Einführung Gamma completa / Complete range / Gamma complete / Produktpalette Limiti d’applicazione / Application limits / Champs d’application / Einsatzgrenzen Prestazioni / Performances Data / Données de puissance / Leistungswerte Ingombri / Overall dimensions / Encombrements / Abmessungen

 Open the catalog to page 2
HI RANGE for inverter use-3

OFFICINE MARIO DORIN SINCE 1918 OFFICINE MARIO DORIN SINCE 1918 INVERTER SYSTEMS ADVANTAGES The use of INVERTER systems together with refrigeration compressors is nowadays subject of several studies conducted both from research institutes and refrigeration systems manufacturers worldwide leader in this field. The main benefits arising from the use of an INVERTER coupled with compressors working into refrigeration units and in refrigeration systems generally speaking, are: • energy savings since the system will absorb less energy; • increase in compressors reliability thanks to the significant...

 Open the catalog to page 3
HI RANGE for inverter use-4

OFFICINE MARIO DORIN SINCE 1918 OFFICINE MARIO DORIN SINCE 1918 INTRODUZIONE / INTRODUCTION / INTRODUCTION / EINFUHRUNG Per esempio e stato recentemente effettuato un paragone relativo al funzionamento di un impianto frigorifero per Supermercati operante con e senza INVERTER. L'impianto era costituito da due centrali, una di media temperatura (denominata TN) ed una di bassa temperatura (denominata BT), entrambe equipaggiate con compressori DORIN. I risultati sono riportati nelle pagine seguenti. I grafici e la tabella seguenti, mostrano i vantaggi cui inizialmente si faceva riferimento,...

 Open the catalog to page 4
HI RANGE for inverter use-5

GAMMA COMPLETA / COMPLETE RANGE / GAMMA COMPLETE / PRODUKTPALETTE INVERTER COMPRESSORS RANGE Since INVERTER applications show significant advantages, DORIN has developed a series of compressors that are perfectly suitable to be coupled with INVERTERS. Thanks to a specific design of moving parts, those compressors are capable to work from 20Hz to 90Hz*. Those compressors have been designed alongside the already challenged H11, H35 and H41 compressors, keeping also their advantages, among them: high C.O.P. values, extremely low vibration phenomena, reduction of pressure pulsation phenomena, IP55 electric...

 Open the catalog to page 5
HI RANGE for inverter use-6

LIMITI D’APPLICAZIONE / APPLICATION LIMITS / CHAMPS D’APPLICATION / EINSATZGRENZEN R134a 80 Applicazione standard Ventilatore su testa oppure max surrisc. 20K Normal operation Head cooling fan or max superheating 20K Application standard Avec ventilateur de culasse ou max surchauffe 20K Standard Einsatz Temperatura condensazione / Condensing temperature Temperature de condensation / Kondensationtemperatur [°C] Zylinderkopfkühlung oder Sauggasüberhitzung 20K max Temperatura evaporazione / Evaporation temperature Temperature d'évaporation / Verdam pfungstem peratur [°C] Applicazione standard Ventilatore...

 Open the catalog to page 6
HI RANGE for inverter use-7

LIMITI D’APPLICAZIONE / APPLICATION LIMITS / CHAMPS D’APPLICATION / EINSATZGRENZEN Applicazione standard Ventilatore su testa oppure max surrisc. 20K Ventilatore su testa + max surrisc. 20K Normal operation Head cooling fan or max superheating 20K Head cooling fan + max superheating 20K Application standard Avec ventilateur de culasse ou max surchauffe 20K Avec ventilateur de culasse + max surchauffe 20K Standard Einsatz Zylinderkopfkühlung oder Sauggasüberhitzung 20K max 60 Temperatura condensazione / Condensing temperature Temperature de condensation / Kondensationtemperatur [°C] Temperatura...

 Open the catalog to page 7
HI RANGE for inverter use-8

PRESTAZIONI / PERFORMANCES DATA / DONNEES DE PUISSANCE / LEISTUNGSWERTE Serie Range Serie Serie R134a ■ Le prestazioni si basano sulla norma europea EN12900 ■ Non miscelare mai olii estere con olii differenti ■ Performance data are based on European Standard EN12900 ■ Never mix ester oils with different oils ■ Les donnees de puissance se basent sur la norme europeenne EN 12900 ■ Ne melanger jamais ester huiles avec different huiles ■ Leistungswerte basieren auf der europaischen Norm EN 12900 ■ Niemals Esterol mit anderen Olen vermischen

 Open the catalog to page 8
HI RANGE for inverter use-9

Serie Range Serie Serie R134a ■ Le prestazioni si basano sulla norma europea EN12900 ■ Non miscelare mai olii estere con olii differenti ■ Performance data are based on European Standard EN12900 ■ Never mix ester oils with different oils ■ Les donnees de puissance se basent sur la norme europeenne EN 12900 ■ Ne melanger jamais ester huiles avec different huiles ■ Leistungswerte basieren auf der europaischen Norm EN 12900 ■ Niemals Esterol mit anderen Olen vermischen

 Open the catalog to page 9
HI RANGE for inverter use-10

PRESTAZIONI / PERFORMANCES DATA / DONNEES DE PUISSANCE / LEISTUNGSWERTE Serie Range Serie Serie R134a ■ Le prestazioni si basano sulla norma europea EN12900 ■ Non miscelare mai olii estere con olii differenti ■ Performance data are based on European Standard EN12900 ■ Never mix ester oils with different oils ■ Les donnees de puissance se basent sur la norme europeenne EN 12900 ■ Ne melanger jamais ester huiles avec different huiles ■ Leistungswerte basieren auf der europaischen Norm EN 12900 ■ Niemals Esterol mit anderen Olen vermischen

 Open the catalog to page 10
HI RANGE for inverter use-11

Serie Range Serie Serie R404A R507 ■ Le prestazioni si basano sulla norma europea EN12900 ■ Non miscelare mai olii estere con olii differenti ■ Performance data are based on European Standard EN12900 ■ Never mix ester oils with different oils ■ Les donnees de puissance se basent sur la norme europeenne EN 12900 ■ Ne melanger jamais ester huiles avec different huiles ■ Leistungswerte basieren auf der europaischen Norm EN 12900 ■ Niemals Esterol mit anderen Olen vermischen

 Open the catalog to page 11
HI RANGE for inverter use-12

PRESTAZIONI / PERFORMANCES DATA / DONNEES DE PUISSANCE / LEISTUNGSWERTE Serie Range Serie Serie R404A R507 ■ Le prestazioni si basano sulla norma europea EN12900 ■ Non miscelare mai olii estere con olii differenti ■ Performance data are based on European Standard EN12900 ■ Never mix ester oils with different oils ■ Les donnees de puissance se basent sur la norme europeenne EN 12900 ■ Ne melanger jamais ester huiles avec different huiles ■ Leistungswerte basieren auf der europaischen Norm EN 12900 ■ Niemals Esterol mit anderen Olen vermischen

 Open the catalog to page 12

All Officine Mario Dorin Spa catalogs and technical brochures

  1. RU SERIES

    4  Pages

  2. 2S-H

    8  Pages

  3. AUT AULN SERIES

    28  Pages

  4. HI SERIES

    36  Pages

  5. WU series

    8  Pages

  6. RU series

    4  Pages

  7. AU SERIES

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.