1. Catalogs
  2. Officine Mario Dorin Spa
  3. Air Cooled Condensing Units for R22

Air Cooled Condensing Units for R22

Air Cooled Condensing Units for R22
1 / 24 PagesView full catalog

Air Cooled Condensing Units for R22

Product catalog summary
Introduction
The AU series of semi-hermetic condensing units are engineered for optimal performance, compactness, and low noise. They are compatible with refrigerants R134a, R404A, R507, R407F, R407A, and R22, within specified limits.
Units Type AU
These standard units are suitable for various applications, featuring air-cooled condensers with copper tubes and aluminum fins, high-efficiency motor fans, liquid receivers with safety valves, and anti-vibration dampers.
Application Envelope
Adherence to specified application limits is crucial for operation and longevity. Any deviation requires pre-approval from OMD.
Noise Level
Motor fans are selected for high performance and low noise, complying with noise regulations.
Lubricants
Compressors use POE oil for HFC refrigerants and mineral oil for R22.
Condensers
Newly designed air-cooled condensers ensure optimal temperatures with high airflow and low noise.
Motor Fans
Innovative hybrid blade motor fans offer quieter operation, higher efficiency, and longer lifespan.
Accessories
Units can include accessories like filter driers, moisture-liquid indicators, and oil separators, designed for easy assembly.
Conformity to PED Directive
Units comply with PED directive 97/23/EC, with a design pressure of 30 bar. Refer to the semi-hermetic compressors catalogue and DORIN software for ASERCOM certified compressors.
Technical Data
Detailed specifications include power consumption, airflow rates, and fan configurations.
Application Limits
Application limits for the D.T.C. device are outlined, emphasizing minimal liquid refrigerant injection and optimal condenser and evaporator design. Performance can reduce by up to 10% based on various conditions.
Operating Conditions
Specific conditions include maximum superheating limits of 20 K and 30 K, with D.T.C. recommended beyond these limits.
Performance Data
Tables provide refrigerating capacity data for different models and conditions, showing capacity in watts for various temperatures.
Technical Recommendations
For precise operating limits, refer to the Dorin selection software and consult the technical department for guidance.
See more

Catalog excerpts

Air Cooled Condensing Units for R22-1

OFFICINE MARIO DORIN SINCE 1918 ////////^- SEMI-HERMETIC CONDENSING UNITS UNITA CONDENSATRICISEMIERMETICHE UNITES DE CONDENSATION SEMI-HERMETIQUE HALBHERMETISCHE KONDENSATIONSEINHEINTEN

 Open the catalog to page 1
Air Cooled Condensing Units for R22-2

INTRODUZIONE / INTRODUCTION / INTRODUCTION / EINFÜHRUNG La serie di unità condensatrici è stata progettata per garantire ottime prestazioni, ingombri ridotti e bassa rumorosità. Tutte le unità possono funzionare con R134a, R404A, R507, R407F, R407A e R22 Rentro i limiti indicati nel presente catalogo. UNITA' TIPO AU Queste unità rappresentano la fornitura standard e sono idonee per tutte le applicazioni. Le unità condensatrici AU sono equipaggiate con condensatore raffreddato ad aria con tubi in rame ed alette in alluminio di nuovo disegno, motoventilatori monofase ad alta efficienza con griglia...

 Open the catalog to page 2
Air Cooled Condensing Units for R22-3

INTRODUZIONE / INTRODUCTION / INTRODUCTION / EINFÜHRUNG I ventilatori sono realizzati con una struttura portante in una lega di alluminio ad alta resistenza alla corrosione, mentre le pale sono in una speciale fibra plastica rinforzata (Hy-Blade fans); questa innovativa combinazione di materiali consente una notevole riduzione di peso. Tutti i ventilatori sono dotati di motore a 230V/1/50-60Hz completo di condensatore e possono essere usati con regolatori elettronici di frequenza; sono dotati di protezione termica interna e di griglia di protezione esterna. Blades are made of a corrosionresistant...

 Open the catalog to page 3
Air Cooled Condensing Units for R22-4

Compressore - Compressor Corrente assorbita Condenser capacity Puissance condenseur Verflüssigerleistung Capacità condensatore Current consumption Max operating current Modello Ventilatori - Motorfans - Ventilateurs - Lüfter Compresseur - Verdichter Applicazioni - Application Application - Anwendungsbereich Condensing unit Unità condensatrice SERIE - RANGE - SÈRIES - SERIE CARATTERISTICHE TECNICHE / TECHNICAL DATA / CARACTERISTIQUES TECHNIQUES / TECHNISCHE MERKMALE

 Open the catalog to page 4
Air Cooled Condensing Units for R22-5

CARATTERISTICHE TECNICHE / TECHNICAL DATA / CARACTERISTIQUES TECHNIQUES / TECHNISCHE MERKMALE Condensing unit Sound pressure (free field) Peso netto Aspirazione Weld Output * Altri tipi di corrente e tensione su richiesta (le capacità frigorifere riportate nelle pagine Schallleistung seguenti sono riferite ad alimentazione di 50/60 Hz). Le portate di aria sono reali e tengono conto delle perdite sul pacco alettato. [dBA] [dBA] [@50Hz] [@60Hz] La formula per ottenere la pressione sonora (Lp) ad una certa distanza (d), conoscendo 68,5 69,7 la potenza sonora (Lw) è: Lp = 68,5 69,7 Lw + 10 Log [K/...

 Open the catalog to page 5
Air Cooled Condensing Units for R22-6

LIMITI D’APPLICAZIONE / APPLICATION LIMITS / CHAMPS D’APPLICATION / EINSATZGRENZEN Temperatura ambiente / Ambient temperature Température ambiante / Umgebungstemperatur [°C] Temperatura evaporazione / Evaporation temperature Temperature d'évaporation / Verdampfungstemperatur [°C] Temperatura ambiente / Ambient temperature Température ambiante / Umgebungstemperatur [°C] Tem peratura evaporazione / Evaporation tem perature Tem perature d'évaporation / Verdam pfungstem peratur [°C]

 Open the catalog to page 6
Air Cooled Condensing Units for R22-7

LIMITI D’APPLICAZIONE / APPLICATION LIMITS / CHAMPS D’APPLICATION / EINSATZGRENZEN Applicazione standard Normal operation Application standard Standard Einsatz Max. surrisc. = 30 K (con Sh>30K aggiungere DTC) Max. superheating = 30 K (if Sh>30K add DTC) Surch. max 30K (avec Sh>30K ajouter DTC) Max. Aufheizung = 30 K (wenn Sh>30K add. DTC) Max. surrisc. = 20 K (con Sh>20K aggiungere DTC) Max. superheating = 20 K (if Sh>20K add DTC) Surch. max 20K (avec Sh>20K ajouter DTC) Max. Aufheizung = 20 K (wenn Sh>20K add. DTC) _______________________________________________________________________________________________________________________________________________________________________...

 Open the catalog to page 7
Air Cooled Condensing Units for R22-8

Applic. - Applic. Applic. - Anwendungsbereich Condensing unit Unità condensatrice SÈRIES - SERIE SERIE - RANGE PRESTAZIONI / PERFORMANCES DATA / DONNÉES DE PUISSANCE / LEISTUNGSWERTE Capacità frigorifera Q0 - Refrigerating capacity Q0 Puissance frigorifique Q0 - Kälteleistung Q0 Temperatura evaporazione [°C] - Evaporating temperature [°C] Température évaporation [°C] - Verdampfungstemperatur [°C] _________________________________ Temperatura gas aspirato 20 °C Rese con sottoraffreddamento del liquido Per condizioni di funzionamento non indicate contattare il nostro servizio tecnico For operating...

 Open the catalog to page 8
Air Cooled Condensing Units for R22-9

Applic. - Applic. Applic. - Anwendungsbereich Condensing unit Unità condensatrice SÈRIES - SERIE SERIE - RANGE PRESTAZIONI / PERFORMANCES DATA / DONNÉES DE PUISSANCE / LEISTUNGSWERTE Capacità frigorifera Q0 - Refrigerating capacity Q0 Puissance frigorifique Q0 - Kälteleistung Q0 Temperatura evaporazione [°C] - Evaporating temperature [°C] Température évaporation [°C] - Verdampfungstemperatur [°C] Rese con sottoraffreddamento del liquido Per condizioni di funzionamento non indicate contattare il nostro servizio tecnico _________________________________ Suction gas temperature 20 °C Capacity with...

 Open the catalog to page 9
Air Cooled Condensing Units for R22-10

Applic. - Applic. Applic. - Anwendungsbereich Condensing unit Unità condensatrice SÈRIES - SERIE SERIE - RANGE PRESTAZIONI / PERFORMANCES DATA / DONNÉES DE PUISSANCE / LEISTUNGSWERTE Capacità frigorifera Q0 - Refrigerating capacity Q0 Puissance frigorifique Q0 - Kälteleistung Q0 Temperatura evaporazione [°C] - Evaporating temperature [°C] Température évaporation [°C] - Verdampfungstemperatur [°C] _________________________________ Temperatura gas aspirato 20 °C Rese con sottoraffreddamento del liquido Per condizioni di funzionamento non indicate contattare il nostro servizio tecnico _________________________________...

 Open the catalog to page 10
Air Cooled Condensing Units for R22-11

Applic. - Applic. Applic. - Anwendungsbereich Condensing unit Unità condensatrice SÈRIES - SERIE SERIE - RANGE PRESTAZIONI / PERFORMANCES DATA / DONNÉES DE PUISSANCE / LEISTUNGSWERTE Capacità frigorifera Q0 - Refrigerating capacity Q0 Puissance frigorifique Q0 - Kälteleistung Q0 Temperatura evaporazione [°C] - Evaporating temperature [°C] Température évaporation [°C] - Verdampfungstemperatur [°C] Rese con sottoraffreddamento del liquido Per condizioni di funzionamento non indicate contattare il nostro servizio tecnico _________________________________ Suction gas temperature 20 °C Capacity with...

 Open the catalog to page 11

All Officine Mario Dorin Spa catalogs and technical brochures

  1. RU SERIES

    4  Pages

  2. 2S-H

    8  Pages

  3. AUT AULN SERIES

    28  Pages

  4. HI SERIES

    36  Pages

  5. WU series

    8  Pages

  6. RU series

    4  Pages

  7. AU SERIES

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.