1. Catalogs
  2. OETIKER
  3. Test Equipment

Test Equipment

Test Equipment

Test Equipment

Product catalog summary
Overview: The document provides technical specifications and operational guidelines for the Oetiker CAL 01 and CAL 02 test equipment, designed for calibrating closing forces of Oetiker clamps to ensure uniform and reproducible process quality.
Specifications: The Oetiker CAL 01 operates on both AC and DC power and includes a convenient carrying case. It is compatible with all types of Oetiker Ear Clamps and Low Profile Clamps that can be closed using a pneumatic pincer. The CAL 01 ensures a constant, reproducible tensile stress within permissible limits.
Calibration and Verification: The CAL 01 is used to adjust and verify the applied closing force. Daily verification of installation tools' closing forces is recommended to maintain process quality. The CAL 01 should be calibrated annually by an authorized institution to comply with local standards.
Delivery Scope: The CAL 01 package includes a calibrator with technical description and operating instructions, a coded load cell with interchangeable pressure jaws, a calibration adaptor, a power transformer, data cables, and a lithium block battery. Optional accessories include various mains units and pressure jaws.
Technical Data: The CAL 01 operates at 100–200 V / 47–63 Hz with a current consumption of 400 mA. Its dimensions are 190 x 110 x 60 mm, and it weighs 0.8 kg (3.4 kg with the complete case).
Oetiker CAL 02: This is a mechanical alternative for closing force calibration, suitable for mechanical tools. It provides high accuracy and covers the entire standard range of closing forces. It can be used with a digital gauge for electronic data exchange.
Oetiker SKM 01 & 02: These are economical alternatives for closing force calibration, suitable for small series and service applications. The SKM 01 covers a closing force range of 1200 N–3400 N, while the SKM 02 covers 3500 N–7500 N.
Contact Information: The document lists contact details for Oetiker's headquarters in Switzerland and various international offices, including those in Austria, Canada, China, France, Germany, and more.
See more

Catalog excerpts

Test Equipment-1

Technical Data Sheet Test Equipment Connecting Technology

 Open the catalog to page 1
Test Equipment-2

Calibration of closing forces Ensures uniform, reproducible process quality Provides an interface for data exchange with any Oetiker electronically controlled installation tool AC or DC operation Convenient carrying case Test Equipment Oetiker CAL 01 Closing forces for Oetiker Clamps All types of Oetiker Ear Clamps and Low Profile Clamps that can be closed using a pneumatic pincer should be closed with a recommended, uniform force. This results in a constant, reproducible tensile stress in the clamp material within the permissible limits and without overloading the individual elements of the...

 Open the catalog to page 2
Test Equipment-3

Calibration of closing forces Technical Data Oetiker Test Equipment Cal 01 Operating voltage: Delivery scope Oetiker Test equipment CAL 01 Calibrator CAL 01 with technical description and operating Coded load cell (SKS 01), assembled with 10 mm wide interchangeable pressure jaws (SKB 10) 7 mm wide pressure jaws (SKB 07) Calibration adaptor Power transformer compatible with local supply Data cables for communication with PC, PLC and ELK / ELS Lithium block battery (BAT 01) Oetiker Test Equipment CAL 01 versions Item No. Optional accessories and spare parts Item No. Mains-plug charger for block...

 Open the catalog to page 3
Test Equipment-4

Calibration of closing forces Mechanical alternative for closing force calibration Ensures uniform and reproducible process quality Force is determined from a conversion table Covers the entire standard range of closing forces Provides electronic data exchange in combination with a suitable digital gauge Test Equipment Oetiker CAL 02 Mechanical alternative to Test Equipment CAL 01. High accuracy – especially suitable for mechanical tools. Versions With MarCator 1087 digital gauge1 With MarCator 1081 digital gauge2 Without dial gauge Delivery scope Digital gauge (electronic data exchange, depends...

 Open the catalog to page 4
Test Equipment-5

Calibration of closing forces Types of Oetiker Closing Force Gauges Oetiker SKM 01 Oetiker SKM 02 Economical alternative for closing force calibration Force indicated by a pointer on a scale Ensures uniform and reproducible process quality Two models available to suit closing force range Developed for ear clamp installation tools Robust plastic carrying case Test Equipment Oetiker SKM 01 & 02 Closing Force Gauges SKM 01/02 offer economical solutions for verifying the closing forces in small series and service applications. Suitable for calibrating installation tools for ear clamps. Delivery scope...

 Open the catalog to page 5
Test Equipment-6

The Oetiker Group: www.oetiker.com Headquarters Switzerland Hans Oetiker AG Maschinen- und Apparatefabrik Oberdorfstrasse 21 CH-8810 Horgen (Zürich) T +41 44 728 55 55 F +41 44 728 55 15 [email protected] Germany Hans Oetiker Metallwaren- & Apparatefabrik GmbH Üsenbergerstrasse 13 D-79346 Endingen a. K. T +49 76 42 6 84-0 F +49 76 42 6 84-125 [email protected] Austria Hans Oetiker Maschinen- und Apparatebau Ges.m.b.H. Eduard-Klinger-Strasse 19 A-3423 St. Andrä-Wördern T +43 2242 33 994-0 F +43 2242 33 997 [email protected] Canada Oetiker Limited 203 Dufferin Street South P. O. Box 5500...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.