Catalog excerpts
Connecting Technology Hand Installation Pincers (HIP) HIP 4000 | 392, HIP 7000 | 393Recommended for the installation of Low Profile Clamp 292 and Ear Clamp 293 Benefits ■ Top sealing performance ■ Ergonomic grip ■ Quick and easy installation Pincer for Low Profile Clamp 292 HIP 4000 | 392 Top sealing performance: superior strength and high closing force Economic design: cost effective for hand installation of low volume assembly or prototypes of ToothLock® clamps Ergonomic grips: safe and simple closure
Open the catalog to page 1Hand Installation Pincers HIP 4000 | 392, HIP 7000 | 393 Jaw 1 Pincer for Low Profile Clamp 292 HIP 4000 | 392 TECHNICAL DATA OVERVIEW Pincer for Low Profile Clamp 292 Pincer for Ear Clamp 293 1 Model No. HIP 4000 | 392 Model No. HIP 7000 | 393 Jaw 1 designed for partial ear pinch, Jaw 2 allows for completion of ear pinch
Open the catalog to page 2Hand Installation Pincers HIP 4000 | 392, HIP 7000 | 393 Assembly tools: Closing Ear Pincer for Low Profile Pincer for Ear Clamp 293 Product Size Force Max. Width Clamp 292 HIP 7000 | 393 Compound Action Tools The compound action mechanism increases the mechanical advantage as the handles are closed, thus providing for higher clamping forces when needed most. A center handle attached to one of the two handles is used to reduce the wide handle span at the beginning of the tool stroke, and folds away conveniently as the handles are brought together. Pincer for Low Profile...
Open the catalog to page 3Hand Installation Pincers HIP 4000 | 392, HIP 7000 | 393 CLOSING FORCE COMPARISON CHARTS HIP 4000 | 392 Jaw force (N) @ 311N applied force Jaw force (N) @ 311N applied force 292 clamp working range. Pincer may exceed 3900N max. closing force of clamp ! otice: Hand pincer closing force consistency cannot be N guaranteed, given the inherent variability of applied force. Reference jaw forces are guidelines only, actual pincer force varies on basis of applied hand force, local worker safety limits and specific application properties. Max closing force of clamp may be exceeded. It is the...
Open the catalog to page 4Hand Installation Pincers HIP 4000 | 392, HIP 7000 | 393 INSTRUCTION GUIDE Minimum closure requirements of each clamp 292 and 293 must be observed for full tooth engagement. Refer to respective clamp Technical Data Sheets for clamp sizing and further assembly details. HIP 4000 | 392 The pincer tip geometry is specifically designed to engage with 292 tensioning tunnels. End of tool stroke coincides with minimum clamp diameter in working range. HIP 7000 | 393 The two jaw pincer is designed to accommodate the large 17 mm Ear. 1. Jaw 1 with wider gap is used first. Center handle effectively...
Open the catalog to page 5All OETIKER catalogs and technical brochures
-
Hand Tubing Cutters
3 Pages
-
Oetiker CP 10, -20
4 Pages
-
Oetiker Quick Connectors
13 Pages
-
PEXGrip
2 Pages
-
ToothLock® Ear Clamps 293
6 Pages
-
Pistol grip
3 Pages
-
HO 10000 ELT - ELK02
3 Pages
-
Test Equipment
6 Pages
-
Compact_Compact XL
4 Pages
-
Swaging tools
8 Pages
-
PG 200
4 Pages
-
Clamps ER
4 Pages
-
1-Ear and 2-Ear Clamps
6 Pages
-
Adjustable Clamps
6 Pages
-
Connecting Solutions
122 Pages
-
Quick Action Couplings SV
28 Pages
-
Swing Couplings SC
28 Pages
-
Catalogue