Technical Specifications: The document provides technical data for the HY 036 air-oil
heat exchangers. It includes information on oil flow rates, pressure drop, viscosity correction, and performance metrics.
Oil Flow and Pressure Drop: The oil flow rates range from 0 to 200 liters per minute. The corresponding pressure drop is measured in bars, with values ranging from 0.1 to 0.7 bar.
Viscosity Correction: Viscosity correction factors are provided for different oil types (ISO VG @ 40 °C), with multiplication factors ranging from 0.7 to 2.
Performance: Performance is measured in kW, with conversion factors provided (1 kW = 860 Kcal/h and 1 kW = 635 HP).
Product Variants: Two product variants, HY03601 and HY03603, are detailed with specifications including oil flow capacity (40 - 160 l/1'), weight (12.6 kg), voltage (230 V or 230/400 V), frequency (50/60 Hz), current (0.95/1.17 A or 1/1.2 A), power (220/270 W or 250/290 W), fan diameter (300 mm), air flow (1800 m3/h), and noise level (73 dB(A)).
Additional Information: The document notes that the technical data are not binding and includes contact information for OESSE S.r.l., the manufacturer.