Technical Specifications: The document provides technical specifications for the HY 130 series of air-oil
heat exchangers manufactured by OESSE S.r.l. Key parameters include oil flow rates ranging from 80 to 320 liters per minute, with specific models like HY13005 and HY13006 having distinct characteristics such as weight, displacement, and fan diameter. The noise level for the HY13005 model is specified at 79 dB(A).
Performance and Efficiency:
Performance metrics are provided, indicating the relationship between oil flow and pressure drop, as well as the efficiency of heat exchange. The document includes a viscosity correction table for different oil types, with correction factors ranging from 0.7 to 2 depending on the oil's ISO VG rating at 40°C.
Additional Information:
The document notes that technical data are not binding, suggesting that specifications may be subject to change. Conversion factors are provided for energy units, with 1 kW equating to 860 Kcal/h or 635 HP.
See more