NEW PRODUCTS CIRCULAR CONNECTORS Benefit from top performance for your specific requirements! HERMETIC SEALING HIGH VOLTAGE TOUCH PROOF BIOCOMPATIBILITY STERILIZATION CIRCULAR CONNECTORS MODULAR CONNECTORS ELECTRICAL CONTACTS

Open the catalog to page 1
NEW PRODUCTS CIRCULAR CONNECTORS - 2

HERMETIC SEALING – NEW ODU MINI-SNAP® RECEPTACLES The requirements for the sealing of electrical transmission interfaces are strongly growing. They have increased from general dust and water tightness (IP rating) in industrial applications to high pressure tightness under water to now almost complete – hermetic sealing. LEVELS OF SEALING REQUIREMENTS HERMETIC SEALING HERMETIC Vacuum/clean room environment Sealing requirements Hermetic sealing is required for example when a vacuum needs to be created in an enclosed area. Between different quality levels of hermetic sealing are distinguished:...

Open the catalog to page 2
NEW PRODUCTS CIRCULAR CONNECTORS - 3

ULTRA “CLEAN” - HIGH SPEED Hermetic sealing means equipment, rooms, production systems etc. are completely protected from the ingress of even the smallest contaminants on a molecular level. With its new series of receptacles, ODU raises the bar in this field. Thanks to glass potting, they not only meet the demanding requirements of UHV-suitable interfaces, but also comply with another major customer requirement - high performance data transfer. Part number MEDICAL a. o. high-end endoscopes TEST AND MEASUREMENT 1 These ODU specific connectors can transmit common data transmission protocols...

Open the catalog to page 3
NEW PRODUCTS CIRCULAR CONNECTORS - 4

Maximum patient and operator protection The medical standard IEC 60601-1 specifies the strictest requirements for contact protection of medical devices and their components to guarantee maximum protection against electric shock for both patients and operators. To keep the risk as low as possible, the standard specifies means of protection (MOP) for medical electric devices and systems that are divided into two categories: Means of patient protection (MOPP) Means of operator protection (MOOP) Working voltage: 250 V AC, pollution degree 2: The information refers to plugs in mated condition....

Open the catalog to page 4
NEW PRODUCTS CIRCULAR CONNECTORS - 5

FIRST-ORDER CRITERION SELECTION OF SPECIAL HOUSINGS Achieving the necessary protection is based on the style of the receptacle or in-line receptacle. The mating connector is not relevant in this scenario. Thicker front nuts on selected styles of receptacles produce a longer insulation distance and simultaneously ensure that patients and operators cannot easily touch the contacts. The information refers to plugs in mated condition. SECOND-ORDER CRITERION SELECTION OF SPECIAL PIN LAYOUTS Achieving the necessary protection is based on the adjustment of the insulator. The style of the...

Open the catalog to page 5
NEW PRODUCTS CIRCULAR CONNECTORS - 6

THE POWER-HOUSE – ODU MEDI-SNAP® All new, high voltage inserts for the ODU MEDI-SNAP® are enabling the reliable transmission of up to 1,000 V AC acc. to IEC 60664. Further they are capable of preventing “hot plugging” by featuring a special pin-layout design with lagging contacts in the smallest possible installation space. CONNECTION STATUS DETECTION 1 × FMLB (FIRST MATE LAST BREAK) The connection status describes whether a connector is fully connected or not. Lagging contacts in the new ODU MEDI-SNAP® connectors define the status “fully connected” by only contacting when they connect....

Open the catalog to page 6
NEW PRODUCTS CIRCULAR CONNECTORS - 7

AVOIDANCE OF “HOT-PLUGGING” IN THE ODU MEDI-SNAP® Corresponding switching units in the device can use the clear identification of the connection status. This can be used to switch the power on or off in a targeted way. This means that electric voltage is only applied at the interface when the connection has been fully and correctly established. This rules out both mating and demating connectors under load and therefore also prevents a resulting damage. It also ensures the long-term functional reliability of the interface itself as well as the connected device. 1 HV: High-Voltage / FMLB:...

Open the catalog to page 7
NEW PRODUCTS CIRCULAR CONNECTORS - 8

Especially in the medical field, hospitals must comply with the highest requirements. Frequently, a sterile environment is a basic condition. The option of sterilization allows long term, germ-free equipment in sensitive environments. STERILIZATION OF ODU MEDI-SNAP®1 + Autoclavability up to 134 °C + Ethylene oxide sterilization with EO gas + Sterrad sterilization with hydrogen peroxide gas + Gamma radiation 1 A list of compliant materials can be send to you upon demand. STERILIZATION if applicable thermal disinfection MULTIPLE USE UP TO 200 STERILIZATION CYCLES

Open the catalog to page 8
NEW PRODUCTS CIRCULAR CONNECTORS - 9

BIOCOMPATIBLE ODU MEDI-SNAP® MATERIALS Using biocompatible materials for the ODU MEDI-SNAP® ensures maximum patient protection against skin and tissue irritations. OPTIMAL LONG-TERM SKIN TOLERANCE Biocompatibility in medicine designates materials that have no negative influence on the metabolic processes of living tissue when in direct contact with it. Patient health is the focus at all times. That’s why it is so important to avoid additional disease symptoms such as allergic reactions in the form of rashes. Therefore, to protect patients, the medical product act requires that medical...

Open the catalog to page 9
NEW PRODUCTS CIRCULAR CONNECTORS - 10

MAXIMUM FLEXIBILITY: THE NEW ODU MEDI-SNAP® RECEPTACLES Top patient protection – Maximum efficiency – High robustness In order to meet the increasing call for improved patient protection according to the IEC 60601-1 as well as the ever-growing cost pressure and demand for high robustness, the ODU MEDI-SNAP® portfolio has been extended to include three new styles of receptacle. Neither water nor dust can ingress into the GA receptacle providing you with the maximum operational reliablity. HIGHEST PATIENT PROTECTION according to IEC 60601-1 2 MOPP FRONT-PANEL INSTALLATION OPTIMIZED COMPONENTS...

Open the catalog to page 10
NEW PRODUCTS CIRCULAR CONNECTORS - 11

THE ADVANTAGES OF THE NEW RECEPTACLES • The IEC 60601-1 medical standard requires affected devices and their components to provide patients and operators with the maximum level of protection from electric shock. Increased clearance and creepage distances fulfill the highest requirements of IEC 60601-1 (2 MOPP / 2 MOOP). • Our outstandingly cost-effective solutions feature optimized components while maintaining top notch quality. MAXIMUM EFFICIENCY • The new GA receptacle type stands out due to its robust design. An additional sealing system has been designed to meet the IP68 standard even...

Open the catalog to page 11