HIGH-SPEED DATA TECHNOLOGY CABLE ASSEMBLIES
Open the catalog to page 1TABLE OF CONTENTS Clickable page numbers CONNECTOR AND CABLE OPTIONS In the field of data technology, a standard cable assembly comprises usually an ODU connector at one end and a standard interface connector at the other end of the cable. You can also get a solution with ODU connectors on both sides of the cable assembly. The catalogue includes the following ODU connectors (availability depends on data protocol): • ODU MINI-SNAP ® (L/K) • ODU AMC ® • ODU AMC ® High-Density • ODU AMC ® Series T • ODU-MAC® Blue-Line Data transmission protocols The contact arrangement of an ODU data transmission...
Open the catalog to page 3ODU FIBER OPTIC EXPANDED BEAM PERFORMANCE Advanced fiber optic solution which offers high-end transmission characteristics over many mating cycles.
Open the catalog to page 4CONNECTOR AND CABLE OPTIONS YOUR WAY TO AN INDIVIDUAL CABLE ASSEMBLY SOLUTION HOW TO CONFIGURE WITH THE CABLE NUMBER KEY This shows you how ODU’s cable number key is composed: • In the first part of the configuration – after the "C" for cable, please insert the first 6 positions of your connector number key. • In the middle part of the cable number key, you configure bend relief, color and count number. • The last 6 positions determine the length of the cable in mm. Cable assembly Note: The qualified standard cables for cable assemblies (see catalog "Standard Cables and Accessories") are available...
Open the catalog to page 5CONNECTOR AND CABLE OPTIONS TECHNICAL DATA Conductor Composition Stranding Jacket / Color Temperature range Tinned copper wire 2 cores stranded to a pair Tinned copper DATA CABLES ETHERNET® TECHNICAL DATA Conductor Stranding Insulation Jacket / Color Shielding Pair shielding Operating temperature Foam-Skin PE, 1.05 mm DMC FLEX PUR, Black LSZH (jacket) / PVC (bend relief) / Black Tinned copper braid Aluminium-coated plastic composite foil -20 °C to +60 °C -40 °C to +75 °C Bare copper wire 2 cores stranded to a pair - 4 pairs
Open the catalog to page 6For further support and customer specific cable solutions please contact: [email protected] CONNECTOR / CABLE OPTIONS CONNECTOR AND CABLE OPTIONS
Open the catalog to page 7CONNECTOR AND CABLE OPTIONS DATA CABLES HDMI® 2.0 TECHNICAL DATA Stranded copper wire Jacket / Color Temperature range Test voltage DATA CABLES HDMI® 2.1 TECHNICAL DATA Stranded copper wire Jacket / Color Temperature range Test voltage
Open the catalog to page 8DATA CABLES DISPLAYPORT® 2.0 TECHNICAL DATA Stranded copper wire Jacket / Color Temperature range Test voltage CONNECTOR / CABLE OPTIONS CONNECTOR AND CABLE OPTION
Open the catalog to page 9CONNECTOR AND CABLE OPTIONS TECHNICAL DATA Jacket / Color Temperature range Test voltage BYTHE METER DATA CABLES USB® 3.2 GEN 1x1 TECHNICAL DATA Conductor UL-Style Jacket / Color Temperature range Test voltage
Open the catalog to page 10DATA CABLES USB® 3.2 GEN 2x2 TECHNICAL DATA PRE-ASSEMBLED –TYPE C PLUG (PASSIVE) Stranded copper wire 8 x AWG 30 / Coaxial 1 x 2 x AWG 30 2 x AWG 28 3 x AWG 30 3 x AWG 30 / Foil shield Jacket / Color Temperature range Temperature range at motion Test voltage CONNECTOR / CABLE OPTIONS
Open the catalog to page 11CONNECTOR AND CABLE OPTIONS • Miniaturized and light weight • Long lifetime with over 5000 mating cycles • Watertight with IP68 and IP69 • Blind mating and demating in difficult-to-reach places • Optimized mechanical and optical color coding available with DP / HDMI® / Ethernet® / USB® ODU AMC® High-Density available with HDMI® / Ethernet® / USB® ODU AMC® SERIES T available with DP / HDMI® / Ethernet® Serie-T 38999 certified
Open the catalog to page 12CONNECTOR AND CABLE OPTIONS ODU MINI-SNAP® SERIES L available with DP / HDMI® / Ethernet® / USB® • Quick and easy mating and demating • Low space requirements on the receptacles • Definite and secure locking conditions CONNECTOR / CABLE OPTIONS ODU MINI-SNAP® SERIES K available with DP / HDMI® / Ethernet® / USB® • Quick and easy mating and demating • Low space requirements on the receptacles • Definite and secure locking conditions
Open the catalog to page 13CONNECTOR AND CABLE OPTIONS Further codings are available on request.
Open the catalog to page 14CONNECTOR AND CABLE OPTIONS COLOR OPTION CONNECTOR / CABLE OPTIONS Silicon bend relief Color bend relief ODU AMC®
Open the catalog to page 15CONNECTOR AND CABLE OPTIONS Ethernet® is the most widely used local area network (LAN) technology that allows devices to communicate with each other using a protocol – a set of rules or a common network language. Ethernet® is a data link layer protocol in the TCP / IP stack that describes how network devices can send and receive data packages so that other devices in the same local or site network segment can find, receive, and process them. An Ethernet® cable is the physical, encapsulated line over which the data is transmitted. Compared to the Wi-Fi technology, Ethernet® is generally less susceptible...
Open the catalog to page 16In configurations with ODU-Connectors on both ends the connector configured on Side A is always the same as Side B. Length L of assembly in mm (minimum cable length 300 mm) Data rates mentioned are based on the respective standard data transmission protocol and are determined by connector size.
Open the catalog to page 18ODU AMC® HIGH-DENSITYEthernet® up to 25000 mm per single side assembly ETHERNET/IP® In configurations with ODU-Connectors on both ends the connector configured on Side A is always the same as Side B. Data rate Length L of assembly in mm (minimum cable length 300 mm) Example: 1000 mm = 001000 Data rates mentioned are based on the respective standard data transmission protocol.
Open the catalog to page 19Data rate* Length L of assembly in mm (minimum cable length 300 mm) Example: 1000 mm = 001000 * Data rates mentioned are based on the respective standard data transmission protocol.
Open the catalog to page 20ODU-MAC® BLUE-LINEEthernet® up to 5000 mm per single side assembly ETHERNET/IP® Pin assembly Socket assembly Length L of assembly in mm (minimum cable length 300 mm) Example: 1000 mm = 1000 Data rates mentioned are based on the respective standard data transmission protocol.
Open the catalog to page 218 Pages
16 Pages
176 Pages
74 Pages
196 Pages
184 Pages
52 Pages
56 Pages
54 Pages
88 Pages
76 Pages
126 Pages
106 Pages