ODOT-MS100T Serial User Manual
15Pages

{{requestButtons}}

Catalog excerpts

ODOT-MS100T Serial User Manual - 1

Industrial Ethernet Switch ODOT-MS105T/108T/116T User Manual http:// www.odotautomation.com

Open the catalog to page 1
ODOT-MS100T Serial User Manual - 2

ODOT Automation System Co., Ltd. 2021-02 Copyright ©2021 ODOT Automation all rights reserved Version Information Date 2021-02-01 http:// www.odotautomation.com Content Release version

Open the catalog to page 2
ODOT-MS100T Serial User Manual - 3

Ownership rights information Without the permission of the copyright owner,all or part of this document shall not be republished as a paper or electronic document. Disclaimer This document is only intended to assist the reader in using the products, and the company shall not be responsible for any loss or error caused by the use of the information in this document. The product and text described in this document are under constant development and refinement. ODOT Automation System Co., Ltd. has the right to modify this document without notifying users. Software download Please log on the...

Open the catalog to page 3
ODOT-MS100T Serial User Manual - 4

http:// www.odotautomation.com

Open the catalog to page 4
ODOT-MS100T Serial User Manual - 5

1.Product Overview 1.1 Product Introduction ODOT-MS105T/108T/116T is a series of plug and play, industrial grade non-management Ethernet switch with 5/8/16 100Mbps ports, all of which support 10/100Mbps auto-negotiation (MDI/MDIX), IEEE 802.3/802.3U / 802.3X, Auto-MDI /MDIX and broadcast storm protection. The switch operating temperature range is -20 ° C to 70 ° C, and it could be applied to a variety of industrial environments with standard 35mm DIN rail installation, and its protection level is IP20. ODOT-MS108T ODOT-MS116T Support IEEE 802.3/802.3x/802.3u 1 way 9~36V DC 2 way 9~36V DC...

Open the catalog to page 5
ODOT-MS100T Serial User Manual - 6

1.3 System Parameter Technical Parameter ODOT-MS105T IEEE 802.3 IEEE 802.3u IEEE 802.3x Process Type ODOT-MS108T ODOT-MS116T 10BaseT 100BaseT(X) Flow Control Storage and forwarding Switch Attribute ODOT-MS105T MAC address size Packet buffer area size Interface Operating Conditions Power Overcurrent Protection Anti-reverse connection protection RJ45 port:10/100BaseT(X) auto-sensing, MDI/MDIX auto-negotiation Temperature:-20~70 ℃ Temperature: -40~85 ℃ 9V~36V DC(suggested 24V) 1.25A Support Anti-reverse connection protection Electric Parameter ODOT-MS105T Operating Voltage Overcurrent...

Open the catalog to page 6
ODOT-MS100T Serial User Manual - 7

2.Hardware description 2.1 Product appearance Take ODOT-MS105T as example(ODOT-MS108T, ODOT-MS116T is similar) http:// www.odotautomation.com

Open the catalog to page 7
ODOT-MS100T Serial User Manual - 8

2.2 Product identification drawing Take ODOT-MS116T as example(ODOT-MS105T,ODOT-MS108T is similar) 2.3 Wiring diagram Table 2.3.1 ODOT-MS105T wiring instruction http:// www.odotautomation.com Wiring instruction Earthing Power input negative Power input positive

Open the catalog to page 8
ODOT-MS100T Serial User Manual - 9

ODOT-MS108T wiring instruction Wiring instruction Earthing Power input negative Power input positive Wiring instruction Earthing Power 2 input negative Power 2 input positive Earthing Power 1 input negative Power 1 input positive 2.4 LED indicator description 1. Power LED Table 2.4.1 Definition Power supply is normal Power supply is abnormal http:// www.odotautomation.com Definition Power supply 1 is normal Power supply 1 is abnormal 9 / 15

Open the catalog to page 9
ODOT-MS100T Serial User Manual - 10

Power supply 2 is normal Power supply 2 is abnormal 2. Network port indicator LED (8 port) Link/Act:Link Status indication, Active: Active indicator ON:Link UP OFF:Link DOWN Flash:Active SHIELD:RJ45 Plug shield interface http:// www.odotautomation.com

Open the catalog to page 10
ODOT-MS100T Serial User Manual - 11

(16 port) Speed:Network speed indicator light (multi-color) Green on:100Mbps Green off:10Mbps Link/Act:Link Status indication, Active indicator ON:Link UP OFF:Link DOWN Flash:Active SHIELD:RJ45 Plug shield interface http:// www.odotautomation.com

Open the catalog to page 11
ODOT-MS100T Serial User Manual - 12

2.5 Installation size Table 2.5.1 http:// www.odotautomation.com

Open the catalog to page 12
ODOT-MS100T Serial User Manual - 13

http:// www.odotautomation.com

Open the catalog to page 13
ODOT-MS100T Serial User Manual - 14

3. Troubleshooting (1) The "PWR" LED is off, please check whether the switch power supply is normal; (2)Insert the cable, but the LED on the Ethernet port is not on. Please check whether the plug at both ends of the cable have been firmly inserted and whether the cable is damaged. ______________________________________________________________ http:// www.odotautomation.com

Open the catalog to page 14
ODOT-MS100T Serial User Manual - 15

Odot Automation System Co., Ltd. Add: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Tel: +86-0816-2538289 Zip Code: 621000 Email:sales@odotautomation.com Web: www.odotautomation.com http:// www.odotautomation.com

Open the catalog to page 15

All ODOT Automation catalogs and technical brochures

  1. BOXIO 64

    4 Pages

  2. PLC

    59 Pages

  3. CN-8034

    2 Pages

  4. CN-8033

    2 Pages

  5. CN-8032

    2 Pages

  6. CN-8012

    2 Pages

  7. CN-8011

    2 Pages

  8. CN-8031

    2 Pages

  9. CT-7221

    17 Pages

  10. CT5800

    15 Pages

  11. CT4234

    20 Pages

  12. CT3804

    21 Pages

  13. CT-3713

    19 Pages

  14. CT3238

    19 Pages

  15. CT-3158

    19 Pages

  16. CT2718

    18 Pages

  17. CT2228

    18 Pages

  18. CT623F

    23 Pages

  19. CT-222F

    19 Pages

  20. CT-121F

    21 Pages

  21. ODOT-IOT02

    44 Pages

  22. ODOT-S7PPIV2.0

    31 Pages

  23. ODOT-PNM02

    31 Pages

  24. ODOT-S4E2

    56 Pages

  25. ODOT-IOT01

    79 Pages