ODOT-IOT01
79Pages

{{requestButtons}}

Catalog excerpts

ODOT-IOT01 - 1

od*t Sichuan Odot Automation System Co., Ltd MG-IOT01 IOT GatewayUser’s ManualV1.22019.11.01 Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 1
ODOT-IOT01 - 2

V' '• « 4 1 ■ * '■ 5 b « I Serial Gateway mg-iotoi Power Supply; 9-36 VDC Operating Temperature: -40-85x •Humidity: 5-95%RH (no,^, Symbol description PWR Power status ETH Ethernet status C01 ISserial status C02 2#serial status C03 3#serial status C04 4#serial status Sichuan Odot Automation System Co, Ltd. http: //www odot.cn Tel/QQ: 400-1024-485 Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 2
ODOT-IOT01 - 3

od*t Sichuan Odot Automation System Co., Ltd Ownership Information This User’s Manual shall not be republished partly or entirely in any paper or electronic forms without authorization from the copyright owner. Disclaimer This User’s Manual is only for the purpose to assist the user in the use of the product, and the company is not responsible for any loss or error caused by the use of the information in this document. The products and texts described in this document are constantly being developed and refined. Sichuan Odot Automation System Co., Ltd. has the right to modify this document...

Open the catalog to page 3
ODOT-IOT01 - 4

Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. 4 / 79

Open the catalog to page 4
ODOT-IOT01 - 5

Od«t Sichuan Odot Automation System Co., Ltd 1 Product Overview 1.1 Product Function Developed by Sichuan Odot Automation System Co., Ltd and based on market demand and years of project experience, MG-IOT01 is a protocol converter supporting to convert a variety of PLC protocols to MODBUS TCP and MQTT protocol. Any device with RS485/RS422/RS232 interface and supporting Siemens (PPI), Omron (HOSTLINK), Mitsubishi (FX series), and Delta (MODBUS) can connect to MODBUS TCP network through this gateway, and through MQTT to cloud platform, so as to connect low-speed serial devices to high-speed...

Open the catalog to page 5
ODOT-IOT01 - 6

Od«t Sichuan Odot Automation System Co., Ltd ♦ Supports data calculation. ♦ 4 serial ports real time refresh, short scanning period, strong loading capacity. ♦ Supports Bridge mode, collecting PLC data without affecting PLC and HMI communication. ♦ With watchdog function, and the watchdog time can be set. ♦ Support IAP download, update and upgrade the firmware program in the product through the network port. ♦ External termination resistor and bias circuit for high stability. ♦ Packet transmission interval can be adjusted freely and is more flexible to use. ♦ Supports one-button reset...

Open the catalog to page 6
ODOT-IOT01 - 7

od*t Sichuan Odot Automation System Co., Ltd Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 7
ODOT-IOT01 - 8

od*t Sichuan Odot Automation System Co., Ltd Serial Gateway mg-iotoi Power Supply; g.36VDC Operating Temperature; -40~85‘c Humidity: 5~95%RH Symbol description PWR Power status ETH Ethernet status C01 1#serial status C02 2#serial status C03 3#serial status C04 4#serial status Sichuan Odot Automation System Co., Ltd. http: //www.odot.cn Tel/QQ: 400-1024-485 2.2 Indicator Description The device has a total of 6 LED status indicators, and its symbol definition and status description are shown in Table 2. Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web:...

Open the catalog to page 8
ODOT-IOT01 - 9

od*t Sichuan Odot Automation System Co., Ltd Table 2. Description of the indicators Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 9
ODOT-IOT01 - 10

od*t Sichuan Odot Automation System Co., Ltd Note: When using the RS422 channel, RS422 channel 1 on the configuration software needs to be configured to COM 1, the indicator light is the indicator light of COM 1; RS422 channel 2 needs to be configured to COM 3, and the indicator light is the indicator light of COM 3. 2.4 RS232/RS422 Dial Setting 1. If the 4 serial ports needs to use RS485 communication, there is no need to adjust the gateway dialing code. The factory default is RS485 communication mode. 2. When the gateway device adopts the RS232 communication interface, the hardware...

Open the catalog to page 10
ODOT-IOT01 - 11

Supply; 5-35^ f8tmg temperature 40'85>r Symbol description Power status ETH Ethernet status C01 1 teens status C02 2#senat status C03 3t$enai status C04 4#sena; status Sichuan Odot Automaton System Co. Lid hup '' wwwodot.cn Tel/QQ 400-1024485 Turn the gateway CH1 and CH3 DIP switches to the ON position, and the serial port 1 and 3 to the RS232 mode. Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 11
ODOT-IOT01 - 12

Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 12
ODOT-IOT01 - 13

Od«t Sichuan Odot Automation System Co., Ltd 3. When the gateway device adopts the RS422 communication interface, the hardware dialing code is as follows: Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 13
ODOT-IOT01 - 14

od«t Sichuan Odot Automation System Co., Ltd 2.5 System Reset The device has a system reset button RESET. When the user forgets the IP address of the device and port number and cannot connect to the gateway, the reset button can be triggered. The system parameters will be restored to the factory settings and the device will be restarted. The reset button can be clicked with a paper clip. All the indicators flash once to indicate that the reset was successful. The technical parameters of the gateway are as follows: Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web:...

Open the catalog to page 14
ODOT-IOT01 - 15

Operating Temperature: -4(h>5«c Humidity: Symbol descnption PWR Power status ETH Ethernet status COI 1#serial status C02 2#serial status C03 3#serial status C04 4#serial status Sichuan Odot Automation System Co., Ltd. http: //www.odot.cn Tel/QQ: 400-1024-485 Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 15
ODOT-IOT01 - 16

2.7 Software Interface 1 Open the software and the main interface as follow: 2. It consists of a Project bar, a Property bar, an Output bar, and a Configuration Information bar. Create a Project and select Configuration Information in the Project bar and configure it in the Configuration Information bar. Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. 16 / 79

Open the catalog to page 16

All ODOT Automation catalogs and technical brochures

  1. BOXIO 64

    4 Pages

  2. PLC

    59 Pages

  3. CN-8034

    2 Pages

  4. CN-8033

    2 Pages

  5. CN-8032

    2 Pages

  6. CN-8012

    2 Pages

  7. CN-8011

    2 Pages

  8. CN-8031

    2 Pages

  9. CT-7221

    17 Pages

  10. CT5800

    15 Pages

  11. CT4234

    20 Pages

  12. CT3804

    21 Pages

  13. CT-3713

    19 Pages

  14. CT3238

    19 Pages

  15. CT-3158

    19 Pages

  16. CT2718

    18 Pages

  17. CT2228

    18 Pages

  18. CT623F

    23 Pages

  19. CT-222F

    19 Pages

  20. CT-121F

    21 Pages

  21. ODOT-IOT02

    44 Pages

  22. ODOT-S7PPIV2.0

    31 Pages

  23. ODOT-PNM02

    31 Pages

  24. ODOT-S4E2

    56 Pages