od-t Sichuan Odot Automation System Co., Ltd Protocol Converter ODOT-S1E1/S2E1User Manual V1.00 2020.07.21
Open the catalog to page 1
2020-02 Copyright ©2019 ODOT Automation all rights reserved The following changes have been made to the document: Ownership rights information Without the permission of the copyright owner, all or part of this document shall http:// www.odotautomation.com 2/ 30 TEL: +86-0816-2538289
Open the catalog to page 2
od-t Sichuan Odot Automation System Co., Ltd not be republished as a paper or electronic document. Disclaimer This document is only intended to assist the reader in using the products, and the company shall not be responsible for any loss or error caused by the use of the information in this document. The product and text described in this document are under constant development and refinement. ODOT Automation System Co., Ltd. has the right to modify this document without notifying users. Software download Please log on the official website: www.odotautomation.com and click on the...
Open the catalog to page 3
http:// www.odotautomation.com
Open the catalog to page 4
od-t Sichuan Odot Automation System Co., Ltd 1. Product Overview 1.1 Product Functions Protocol converter is a converter developed by Sichuan Odot Automation System Co., LTD between RS232/485/422 and TCP/UDP.This protocol converter can easily connect serial port devices to Ethernet and realize network upgrade of serial port devices. Protocol converter supports the function of "data transmission", which can be set as a client or a server. This function can easily realize the data communication between PLC, server and other Ethernet devices and the underlying serial port devices. Modules that...
Open the catalog to page 5
od-t Sichuan Odot Automation System Co., Ltd ♦ Support DHCP, more convenient to use. ♦ Support one-key reset function to restore factory Settings. ♦ 35mm standard DIN-rail installation. ♦ EMC meets EN 55022:2010 & EN55024:2010 international standards. 1.3 Technical parameters The technical parameters of this product are shown in Table 3.1. Please use this product within the parameters of this product to obtain better performance. Table 3.1 Technical parameters http:// www.odotautomation.com
Open the catalog to page 6
od-t Sichuan Odot Automation System Co., Ltd http:// www.odotautomation.com
Open the catalog to page 7
od-t Sichuan Odot Automation System Co., Ltd Caution: ODOt-S1E1 has only one serial port, while ODOt-S2E1 has two serial ports. 2.3 Terminal definition The equipment connection adopts 10Pin 3.81mm distance unplugging terminal. The RS485 interface terminal is defined as follows. ODOT-S1E1 Terminal definition http:// www.odotautomation.com
Open the catalog to page 8
od-t Sichuan Odot Automation System Co., Ltd http:// www.odotautomation.com
Open the catalog to page 9
od-t Sichuan Odot Automation System Co., Ltd The paper clip can be used to click the reset button, and all the indicators blink once to indicate a successful reset. Gateway reset successfully, the technical parameters of the gateway are as follows: http:// www.odotautomation.com
Open the catalog to page 10
od-t Sichuan Odot Automation System Co., Ltd 2.5 External terminal resistance According to the actual situation, a serial port side need external gateway 120 Q terminal resistance.RS485 bus in the case of no trunk to support a maximum of 32 nodes, node and node between the "Daisy chain" connection mode, in the communication cable at both ends need to add terminal resistance, the resistance http:// www.odotautomation.com
Open the catalog to page 11
od-t Sichuan Odot Automation System Co., Ltd value is required to be approximately equal to the transmission cable characteristic impedance. In short distance transmission, no final resistance is required, that is, no final resistance is generally required below 300 meters. The final resistance is connected at the ends of the transmission cable. Gateway in field application, if the RS485 bus distance, big field interference will need to add 120 Q on both ends of the RS485 bus terminal resistance, in order to prevent the reflection of serial signal. Note: 120 Q resistance attached to the...
Open the catalog to page 12
od-t Sichuan Odot Automation System Co., Ltd 3. Typical application S1E1 supports TCP server, TCP client, UDP pure transparent transmission mode. The transparent transmission mode supports transparent transmission with and without protocol. The S1E1 supports browser configuration and it directly forwarding data without storing. 3.1 Transparent transmission with protocol data Example: ODOT-S1E1 was used for testing. On-site RS485 device (MODBUS RTU communication protocol is adopted for communication, serial port parameters: ID=1,19200 BPS, N81). Modbus Slave test software was used to...
Open the catalog to page 13
Od*t Sichuan Odot Automation System Co., Ltd set this parameter to be consistent with the device connected to the serial port. Parity checking: No check, odd check, even check can be selected, default no check, please set this parameter to the serial port. The connected devices are consistent. Stop bits: 1 bit, 2 bit stop is optional, default is 1 bit stop. Set this parameter to match the device to which the serial port is connected. Received character interval: The detection time of frame interval when receiving a message, 1.5t~200t optional, default 3.5T (T is the time of single character...
Open the catalog to page 14
2.In the webpage setting interface, the configuration parameters of the protocol converter are set according to the serial port parameters of the serial port device. Serial Server DHCP Enabled Subnet mask parity bits Message frame interval Slave response time(ms) Protocol type server address Note: There are two modes available for transmission: RTU_MODE and ASCII_MODE. Select RTU_MODE here. Ethernet connection mode has TCP_SERVER, TCP_CLINET, UDP_CONNECT three ways to choose. Select the TCP_SERVER mode here. 3. After setting the parameters, click Submit configuration to download to the...
Open the catalog to page 15
again. If you forget to log in IP, you can press the reset key to restore factory Settings by logging in gateway through 192.168.1.254 and reconfigure parameters before using. 4. After setting, open MODBUS POLL software to test whether the data is collected normally. Modbus Poll - [Mbpolll] — □ X File Edit Connection Setup Functions Display View Window Help _ fi1 > ^3 Modbus Slave - [Mbslavel] — □ X File Edit Connection Setup Display View Window Help _ iF |For Help, press FI. | [192.168.1.254]; 502 | |For Help, press FI. 5. When testing ODOt-S2E1, there are two serial ports. When serial...
Open the catalog to page 16All ODOT Automation catalogs and technical brochures
-
C3351
8 Pages
-
ODOT C series remote IO
4 Pages
-
BOXIO 64
4 Pages
-
ODOT remote IO catalogue
20 Pages
-
PLC
59 Pages
-
New small ODOT brochure
16 Pages
-
CN-8034
2 Pages
-
CN-8033
2 Pages
-
CN-8032
2 Pages
-
CN-8012
2 Pages
-
CN-8011
2 Pages
-
CN-8031
2 Pages
-
Remote I/O C Series
376 Pages
-
ODOT-MS100T Serial User Manual
15 Pages
-
Remote I/O module
36 Pages
-
CT-7221
17 Pages
-
CT5800
15 Pages
-
CT4234
20 Pages
-
CT3804
21 Pages
-
CT-3713
19 Pages
-
CT3238
19 Pages
-
CT-3158
19 Pages
-
CT2718
18 Pages
-
CT2228
18 Pages
-
CT623F
23 Pages
-
CT-222F
19 Pages
-
CT-121F
21 Pages
-
ODOT-PNM02 User Manual_V1.5.
37 Pages
-
MG-IOT03 User Manual_V1
24 Pages
-
ODOT-IOT02
44 Pages
-
ODOT AIOBOX - Integrated IO module
149 Pages
-
ODOT-S7PPIV2.0
31 Pages
-
ODOT-PNM02
31 Pages
-
ODOT-S4E2
56 Pages
-
ODOT-IOT01
79 Pages