ODOT AIOBOX - Integrated IO module
1 / 149Pages

Catalog excerpts

ODOT AIOBOX - Integrated IO module - 1

od*t Sichuan Odot Automation System Co., Ltd Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 1
ODOT AIOBOX - Integrated IO module - 2

OCM Sichuan Odot Automation System Co., Ltd Sichuan Odot Automation System Co., Ltd. 2018-3 Copyright©2010. All Rights Reserved. Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 2
ODOT AIOBOX - Integrated IO module - 3

od*t Sichuan Odot Automation System Co., Ltd Version Information Ownership Information This User’s Manual shall not be republished partly or entirely in any paper or electronic forms without authorization from the copyright owner. Disclaimer This User’s Manual is only for the purpose to assist the user in the use of the product, and the company is not responsible for any loss or error caused by the use of the information in this document. The products and texts described in this document are constantly being developed and refined. Sichuan Odot Automation System Co., Ltd. has the right to...

Open the catalog to page 3
ODOT AIOBOX - Integrated IO module - 4

Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China.

Open the catalog to page 4
ODOT AIOBOX - Integrated IO module - 7

Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China.

Open the catalog to page 7
ODOT AIOBOX - Integrated IO module - 8

Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China.

Open the catalog to page 8
ODOT AIOBOX - Integrated IO module - 10

Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China.

Open the catalog to page 10
ODOT AIOBOX - Integrated IO module - 11

od*t Sichuan Odot Automation System Co., Ltd Fa*ft. AfiOMKUMMHIil P«cui Hat* AtDICx Mm K) uxu* AIOBOX-16 supports a single-layer baseplate (A plate), 3 slots. Slot 0 is the adapter slot, and slot 1/2 are the IO module slots. AIOBOX-32 supports double-layer baseplate (A / B plates), 5 slots. Slot 0 is the adapter slot, and slot 1/2/3/4 are the IO module slots. Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 11
ODOT AIOBOX - Integrated IO module - 12

od*t Sichuan Odot Automation System Co., Ltd Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 12
ODOT AIOBOX - Integrated IO module - 13

od*t Sichuan Odot Automation System Co., Ltd Note: Please refer to the selection table above for details. Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 13
ODOT AIOBOX - Integrated IO module - 14

Od«t Sichuan Odot Automation System Co., Ltd 1.3.1 System Power and Communication Interface The top of the device is the system power interface and network communication interface. The system power interface uses plug-in screw terminals or spring terminals for wiring. The network communication interface has different configurations according to different adapter modules, including RJ45 physical interface, DB9 physical interface, etc. At the same time, the top contains functions such as device station address dial switches. Note: depending on the adapter protocol, the terminal, communication...

Open the catalog to page 14
ODOT AIOBOX - Integrated IO module - 15

Od«t Sichuan Odot Automation System Co., Ltd information such as the IP address of the device and cannot connect to the gateway, the reset button can be triggered. The system parameters will be restored to factory settings and the device restarted. After resetting, the configuration parameters can be downloaded again. CFG is the device configuration port. Please use the MicroUSB data cable provided with the product for hardware connection. It can be connected to the supporting upper computer software through the configuration port, and supports functions like Device Search, Parameter...

Open the catalog to page 15
ODOT AIOBOX - Integrated IO module - 16

2 Network Adapter Module 2.1 AIO-X8031 Modbus Network Adapter Module 2.1.1 Module Introduction AIO-X8031 Modbus network adapter module supports standard Modbus-TCP and Modbus-RTU / ASCII protocol access at the same time. Ethernet supports dual network port switch cascading function, and serial port supports RS485 Bus connection. 2.1.2 Baseplate Parameters Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 16
ODOT AIOBOX - Integrated IO module - 17

od*t Sichuan Odot Automation System Co., Ltd Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 17
ODOT AIOBOX - Integrated IO module - 18

od*t Sichuan Odot Automation System Co., Ltd Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 18
ODOT AIOBOX - Integrated IO module - 19

od*t Sichuan Odot Automation System Co., Ltd Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 19
ODOT AIOBOX - Integrated IO module - 20

od*t Sichuan Odot Automation System Co., Ltd Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 20
ODOT AIOBOX - Integrated IO module - 21

od*t Sichuan Odot Automation System Co., Ltd Data description: MAC Address [0-5]: Device MAC address (read-only) IP Address [0-3]: Device IP address (default: 192.168.1.100) Net Mask [0-3]: Device subnet mask (default: 255.255.255.0) Net Gateway [0-3]: Device subnet gateway (default: 192.168.1.1) Modbus Port: Modbus Port number (default: 502) Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 21
ODOT AIOBOX - Integrated IO module - 22

od*t Sichuan Odot Automation System Co., Ltd Valid range: 0-65535 Watchdog Enable: Modbus watchdog enable (default: 1) 0: Watchdog prohibited 1: Watchdog enabled Watchdog Time(s):Watchdog time (default: 10) Valid range: 1-65535 Slave ID: Modbus slave ID number (default: 1) Valid range: 1-247Baud Rate:(:9600bps)Serial baud rate (default:9600bps) Valid range: 2400-115200 Data Bits: Data bits (default: 8) 7: 7 data bits 8: 8 data bits Parity Bits: Check digit (default: 0) 0: No parity 1: Odd parity 2: Even parity Stop Bits: Stop bit (default: 1) 1: 1 stop bit 2: 2 stop bits Serial Mode: Serial...

Open the catalog to page 22
ODOT AIOBOX - Integrated IO module - 23

od*t Sichuan Odot Automation System Co., Ltd 2:5t 3:10t 4:20t 5:50t 6:100t 7:200t Respond Delay: Slave response delay time (default: 0) Valid range: 0-65535 Real-time data exchange is performed between the network adapter and the extended IO module, and the data address table is dynamically allocated according to the different modules placed in the IO slot. For the actual mapping address, please refer to the "Address Table” page of the AIOBOX configuration software interface. Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 23
ODOT AIOBOX - Integrated IO module - 24

od*t Sichuan Odot Automation System Co., Ltd 2.2 AIO-X8032 PROFINET Network Adapter Module 2.2.1 Module Introduction AIO-X8032 Profinet I/O IRT network adapter module supports standard Profinet protocol access, and the network adapter supports up to 4 extended IO modules. Add.: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Web: www.odotautomation.com

Open the catalog to page 24

All ODOT Automation catalogs and technical brochures

  1. C3351

    8 Pages

  2. BOXIO 64

    4 Pages

  3. PLC

    59 Pages

  4. CN-8034

    2 Pages

  5. CN-8033

    2 Pages

  6. CN-8032

    2 Pages

  7. CN-8012

    2 Pages

  8. CN-8011

    2 Pages

  9. CN-8031

    2 Pages

  10. CT-7221

    17 Pages

  11. CT5800

    15 Pages

  12. CT4234

    20 Pages

  13. CT3804

    21 Pages

  14. CT-3713

    19 Pages

  15. CT3238

    19 Pages

  16. CT-3158

    19 Pages

  17. CT2718

    18 Pages

  18. CT2228

    18 Pages

  19. CT623F

    23 Pages

  20. CT-222F

    19 Pages

  21. CT-121F

    21 Pages

  22. ODOT-IOT02

    44 Pages

  23. ODOT-S7PPIV2.0

    31 Pages

  24. ODOT-PNM02

    31 Pages

  25. ODOT-S4E2

    56 Pages

  26. ODOT-IOT01

    79 Pages

Archived catalogs