Support Tel: +86‑816‑6337503 Sales Tel: +86‑816‑2538289 Email:[email protected] Web: www.odotautomation.com Address: 204 MianYang Comprehensive Bonded Zone, Hi‑Tech District, Eastern section of FeiYun Avenue, MianYang,Sichuan Province,China.621000 Product Brochure
Open the catalog to page 1ODOT founded in 2003, offers reliable, stable and bankable solutions to help you simplify your production process. As a national high‑tech enterprise, we are specializing in industrial communication product R&D, industrial automation control system design, integration and technical services. our product has Verification of EMC compliance "CE" BY SGS and Quality Management system ISO9001:2015, We are also a member of PROFIBUS &PROFINET Association (PIChina), EtherCAT Technology Association, CC‑Link, OPC, CCIA, Industrial Internet Alliance and other associations. ODOT has successfully provided professional field data collection solutions for AUTOs and New ...
Open the catalog to page 2Grain and oil machinery Smart factory AUTO Energy Industry Thermal plant Lithium battery industry Wind power Process Control Sewage disposal Oil and Gas Chemical Other Industry Railway Urban rail Building HVAC
Open the catalog to page 3Network adapter Modbus RTU(RS485) CN‑8011 Profibus‑DP CN‑8012 B series modular integrated IO A series modular integrated IO Modbus‑RTU to Profinet ODOT‑PNM02 V2.0 CANopen/Modbus TCP MG‑CANEX
Open the catalog to page 4IO module Digital Input Modules Digital Output Modules Analog Input Modules Analog Output Modules CC‑Link IE Filed Basic CC‑Link IE Filed Basic PowerLink PowerLink vertical insertion terminal 9PIN spring block terminal light guide power supply high‑speed backplane bus configuration Interface identification product model information C series – the remote IO system consists of network adapter module and extended IO module. The network adapter module is responsible for fieldbus communication, and it could realize the communication with the master controller or ho
Open the catalog to page 5I O Modules、 Terminal Module 网络适配器 75mm Field BUS: Modbus RTU、 Profibus‑DP、 CC‑Link、 CANopen、 DeviceNet Industrial Networking: Modbus TCP、 Profinet、 EtherNet/IP、 EtherCAT、 CC‑Link IE Network Adapter Textile Machinery Field BUS: Modbus‑RTU、 Profibus‑DP、 CC‑Link、 CANopen、 DeviceNet Industrial Networking: Modbus‑TCP、 ProfiNet、 EtherNet/IP、 EtherCAT、 CC‑Link IE
Open the catalog to page 6Field BUS: Profibus‑DP、 CC‑Link、 CANopen、 DeviceNet Industrial Networking: Modbus TCP、 Profinet、 EtherNet/IP、 EtherCAT、 CC‑Link IE Modbus RTU Slave Station Field Field Power Power Industrial Networking: Modbus TCP、 Profinet、 EtherNet/IP、 EtherCAT、 CC‑Link IE STAT STAT Programmable I/O EtherCAT Field BUS: Profibus‑DP、 CC‑Link、 CANopen、 DeviceNet STAT STAT Modbus RTU Master Station Programmable I/O EtherCAT Field Field Power Power
Open the catalog to page 7◆BOXIO‑32 carries 1 communication board and 2 IO slots, BOXIO‑64 carries 1 communication board and 4 IO slots; ◆The communication protocols with Modbus‑TCP, Profinet, EtherCAT, EtherNet/IP are optional for the communication board; ◆Slots 1/2/3/4 can be independently selected according to customer IO requirements, and a single module supports up to 16 channels; ◆With LCD display, you can view information such as communication parameters, IO channel status, module version, etc.; ◆Plastic shell, small size, easy to install; ◆Independent design, can be customized by OEM and ODM;
Open the catalog to page 8◆AIOBOX‑16 supports 3 slots, slot 0 for communication board, slot 1/2 for IO module; ◆AIOBOX‑32 supports 5 slots, slot 0 for communication board, slot 1/2/3/4 for IO module; ◆The communication protocols with Modbus TCP/Modbus RTU、 Profinet、 EtherCAT、 Profibus‑DP、 CANopen are optional for the communication board; ◆Slot 1/2/3/4 can be selected according to customer needs, Max. 32 channels ◆Working temperature: ‑40℃~85℃ IO Modules (Max.2 IO for AIOBOX‑16 and Max.4 for AIOBOX‑32): Adapter Type: PROFINET IO device Ethernet Port: 2 ports with switch function Speed: 10/100Mbps adaptive, Auto‑MDI/MDIX...
Open the catalog to page 9ODOT‑PNM02 V2.0 gateway is a Modbus‑RTU/ASCII to PROFINET protocol converter. This product can connect Modbus device to PLC(S7‑ 300/1200/1500/400) with PROFINET communication interface. It adopts aluminum alloy shell with firm design and supports DIN‑rail installation. All serial signal provides built‑in photoelectric isolation. ◆Supports protocol conversion between Modbus and PROFINET ◆Supports 2* RS485/RS232 or 1*RS422 ◆Supports Modbus master or slave, and supports RTU or ASCII ◆Supports working temperature of ‑40~85℃ ◆Supports data area: 2 serial Modbus‑RTU/ASCII to PROFIBUS gateway with ...
Open the catalog to page 10◆Supports protocol conversion between Modbus‑RTU and Modbus‑TCP ◆Supports the connection of 5 TCP clients simultaneously ◆ODOT‑S2E2 supports 2*RS485 ◆ODOT‑S4E2 supports wiring of RS485/RS232/RS422 ◆Each serial port supports Modbus master and slave ◆ODOT‑S2E2: 2 serial Modbus‑RTU/ASCII to Modbus‑TCP Server gateway ◆ODOT‑S4E2: 4 serial Modbus‑RTU/ASCII to Modbus‑TCP Server gateway ◆Supports one key reset ◆Gateway working mode: Transparent transmission, address mapping ODOT‑S2E2/S4E2 gateway is a Modbus‑RTU/ASCII to Modbus‑TCP protocol converter. This product can connect Modbus device to PLC and master computer ...
Open the catalog to page 11◆Dual Ethernet port with switch function, support cascade ◆2KV network port isolation protection, 10M/100Mbps rate adaptive, (Auto‑MDI/MDIX) ◆Supports address mapping mode, to achieve rapid response to TCP client requests ◆Supports up to 10 TCP clients accesses ◆6KB large data cache area, more data transfer ◆CAN interface supports CANopen, CAN2.0A and CAN2.0B ◆Equipped with powerful diagnostic function, real‑time monitoring of communication status from the slave device ◆Supports One‑Key reset function, restore to factory settings ◆EMC complies with EN 55022:2010 & EN55024:2010 international ...
Open the catalog to page 12◆ Supports TCP server and TCP client transparent transmission ◆ Supports UDP transparent transmission and virtual serial ports ◆ Supports transparent transmission with or without protocol. Protocol ◆ Supports WEB browser configuration parameters (Common parameters) ◆ Serial port baud rate 1200 to 115200 bps ◆ Supports transparent transmission through MQTT Typical application topology Client 2 Modbus RTU/ASCII Remote IO ◆10/100 Mbps self‑adaption (Auto‑MDI/MDI‑X) ◆All supports IEEE802.3/802.3u/802.3x/802.3z ◆Supports broadcast storm protection ◆Working temperature range: ‑20~70℃; ◆5/8/16 ports unmanaged Ethernet Switches DIN‑rail...
Open the catalog to page 138 Pages
4 Pages
4 Pages
20 Pages
59 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
376 Pages
15 Pages
36 Pages
17 Pages
15 Pages
20 Pages
21 Pages
19 Pages
19 Pages
19 Pages
18 Pages
18 Pages
23 Pages
19 Pages
21 Pages
37 Pages
24 Pages
44 Pages
149 Pages
31 Pages
31 Pages
56 Pages
79 Pages
30 Pages