Catalog excerpts

Support Tel: +86‑816‑6337503 Sales Tel: +86‑816‑2538289 Email:sales@odotautomation.com Web: www.odotautomation.com Address: 204 MianYang Comprehensive Bonded Zone, Hi‑Tech District, Eastern section of FeiYun Avenue, MianYang,Sichuan Province,China.621000 Product Brochure
Open the catalog to page 1
ODOT founded in 2003, offers reliable, stable and bankable solutions to help you simplify your production process. As a national high‑tech enterprise, we are specializing in industrial communication product R&D, industrial automation control system design, integration and technical services. our product has Verification of EMC compliance "CE" BY SGS and Quality Management system ISO9001:2015, We are also a member of PROFIBUS &PROFINET Association (PIChina), EtherCAT Technology Association, CC‑Link, OPC, CCIA, Industrial Internet Alliance and other associations....
Open the catalog to page 2
Grain and oil machinery Smart factory AUTO Energy Industry Thermal plant Lithium battery industry Wind power Process Control Sewage disposal Oil and Gas Chemical Other Industry Railway Urban rail Building HVAC
Open the catalog to page 3
Network adapter Modbus RTU(RS485) CN‑8011 Profibus‑DP CN‑8012 B series modular integrated IO A series modular integrated IO Modbus‑RTU to Profinet ODOT‑PNM02 V2.0 CANopen/Modbus TCP MG‑CANEX
Open the catalog to page 4
IO module Digital Input Modules Digital Output Modules Analog Input Modules Analog Output Modules CC‑Link IE Filed Basic CC‑Link IE Filed Basic PowerLink PowerLink vertical insertion terminal 9PIN spring block terminal light guide power supply high‑speed backplane bus configuration Interface identification product model information C series – the remote IO system consists of network adapter module and extended IO module. The network adapter module is responsible for fieldbus communication, and it could realize the communication with the master controller or ho
Open the catalog to page 5
I O Modules、 Terminal Module 网络适配器 75mm Field BUS: Modbus RTU、 Profibus‑DP、 CC‑Link、 CANopen、 DeviceNet Industrial Networking: Modbus TCP、 Profinet、 EtherNet/IP、 EtherCAT、 CC‑Link IE Network Adapter Textile Machinery Field BUS: Modbus‑RTU、 Profibus‑DP、 CC‑Link、 CANopen、 DeviceNet Industrial Networking: Modbus‑TCP、 ProfiNet、 EtherNet/IP、 EtherCAT、 CC‑Link IE
Open the catalog to page 6
Field BUS: Profibus‑DP、 CC‑Link、 CANopen、 DeviceNet Industrial Networking: Modbus TCP、 Profinet、 EtherNet/IP、 EtherCAT、 CC‑Link IE Modbus RTU Slave Station Field Field Power Power Industrial Networking: Modbus TCP、 Profinet、 EtherNet/IP、 EtherCAT、 CC‑Link IE STAT STAT Programmable I/O EtherCAT Field BUS: Profibus‑DP、 CC‑Link、 CANopen、 DeviceNet STAT STAT Modbus RTU Master Station Programmable I/O EtherCAT Field Field Power Power
Open the catalog to page 7
◆BOXIO‑32 carries 1 communication board and 2 IO slots, BOXIO‑64 carries 1 communication board and 4 IO slots; ◆The communication protocols with Modbus‑TCP, Profinet, EtherCAT, EtherNet/IP are optional for the communication board; ◆Slots 1/2/3/4 can be independently selected according to customer IO requirements, and a single module supports up to 16 channels; ◆With LCD display, you can view information such as communication parameters, IO channel status, module version, etc.; ◆Plastic shell, small size, easy to install; ◆Independent design, can be customized by OEM and ODM;
Open the catalog to page 8
◆AIOBOX‑16 supports 3 slots, slot 0 for communication board, slot 1/2 for IO module; ◆AIOBOX‑32 supports 5 slots, slot 0 for communication board, slot 1/2/3/4 for IO module; ◆The communication protocols with Modbus TCP/Modbus RTU、 Profinet、 EtherCAT、 Profibus‑DP、 CANopen are optional for the communication board; ◆Slot 1/2/3/4 can be selected according to customer needs, Max. 32 channels ◆Working temperature: ‑40℃~85℃ IO Modules (Max.2 IO for AIOBOX‑16 and Max.4 for AIOBOX‑32): Adapter Type: PROFINET IO device Ethernet Port: 2 ports with switch function...
Open the catalog to page 9
ODOT‑PNM02 V2.0 gateway is a Modbus‑RTU/ASCII to PROFINET protocol converter. This product can connect Modbus device to PLC(S7‑ 300/1200/1500/400) with PROFINET communication interface. It adopts aluminum alloy shell with firm design and supports DIN‑rail installation. All serial signal provides built‑in photoelectric isolation. ◆Supports protocol conversion between Modbus and PROFINET ◆Supports 2* RS485/RS232 or 1*RS422 ◆Supports Modbus master or slave, and supports RTU or ASCII ◆Supports working temperature of ‑40~85℃...
Open the catalog to page 10
◆Supports protocol conversion between Modbus‑RTU and Modbus‑TCP ◆Supports the connection of 5 TCP clients simultaneously ◆ODOT‑S2E2 supports 2*RS485 ◆ODOT‑S4E2 supports wiring of RS485/RS232/RS422 ◆Each serial port supports Modbus master and slave ◆ODOT‑S2E2: 2 serial Modbus‑RTU/ASCII to Modbus‑TCP Server gateway ◆ODOT‑S4E2: 4 serial Modbus‑RTU/ASCII to Modbus‑TCP Server gateway ◆Supports one key reset ◆Gateway working mode: Transparent transmission, address mapping ODOT‑S2E2/S4E2 gateway is a Modbus‑RTU/ASCII to Modbus‑TCP protocol converter. This product can ...
Open the catalog to page 11
◆Dual Ethernet port with switch function, support cascade ◆2KV network port isolation protection, 10M/100Mbps rate adaptive, (Auto‑MDI/MDIX) ◆Supports address mapping mode, to achieve rapid response to TCP client requests ◆Supports up to 10 TCP clients accesses ◆6KB large data cache area, more data transfer ◆CAN interface supports CANopen, CAN2.0A and CAN2.0B ◆Equipped with powerful diagnostic function, real‑time monitoring of communication status from the slave device ◆Supports One‑Key reset function, restore to factory settings...
Open the catalog to page 12
◆ Supports TCP server and TCP client transparent transmission ◆ Supports UDP transparent transmission and virtual serial ports ◆ Supports transparent transmission with or without protocol. Protocol ◆ Supports WEB browser configuration parameters (Common parameters) ◆ Serial port baud rate 1200 to 115200 bps ◆ Supports transparent transmission through MQTT Typical application topology Client 2 Modbus RTU/ASCII Remote IO ◆10/100 Mbps self‑adaption (Auto‑MDI/MDI‑X) ◆All supports IEEE802.3/802.3u/802.3x/802.3z ◆Supports broadcast storm protection ◆Working temperature range: ‑20~70℃;...
Open the catalog to page 13All ODOT Automation catalogs and technical brochures
-
C3351
8 Pages
-
ODOT C series remote IO
4 Pages
-
BOXIO 64
4 Pages
-
ODOT remote IO catalogue
20 Pages
-
PLC
59 Pages
-
CN-8034
2 Pages
-
CN-8033
2 Pages
-
CN-8032
2 Pages
-
CN-8012
2 Pages
-
CN-8011
2 Pages
-
CN-8031
2 Pages
-
Remote I/O C Series
376 Pages
-
ODOT-MS100T Serial User Manual
15 Pages
-
Remote I/O module
36 Pages
-
CT-7221
17 Pages
-
CT5800
15 Pages
-
CT4234
20 Pages
-
CT3804
21 Pages
-
CT-3713
19 Pages
-
CT3238
19 Pages
-
CT-3158
19 Pages
-
CT2718
18 Pages
-
CT2228
18 Pages
-
CT623F
23 Pages
-
CT-222F
19 Pages
-
CT-121F
21 Pages
-
ODOT-PNM02 User Manual_V1.5.
37 Pages
-
MG-IOT03 User Manual_V1
24 Pages
-
ODOT-IOT02
44 Pages
-
ODOT AIOBOX - Integrated IO module
149 Pages
-
ODOT-S7PPIV2.0
31 Pages
-
ODOT-PNM02
31 Pages
-
ODOT-S4E2
56 Pages
-
ODOT-IOT01
79 Pages
Archived catalogs
-
ODOT-S1E1 User Manual 20200720
30 Pages