Product catalog summary
Product Overview
  • Introduction: The MG-IOT03 is an industrial-grade Ethernet gateway designed for protocol conversion, supporting Siemens S7 Ethernet to Modbus TCP and MQTT protocols. It features 5 Ethernet ports with auto-negotiation capabilities.
  • Functionality: The gateway supports up to 200 collection points, data type conversion, and firmware updates via network port. It operates in a wide temperature range (-40 to 85°C) and includes a one-key reset and standard guide rail installation.
  • Technical Parameters: It operates on a 9-36V DC power supply, with a maximum power consumption of 200mA at 24V. It supports various network protocols including ETHERNET, ARP, IP, TCP, ICMP, and MQTT.
Hardware Description
  • Indicator Lights: The PWR light indicates power status, while the RUN light indicates system operation and data exchange status.
  • Terminal Definition: Provides connection identifiers for power input and protected land.
  • One-Key Reset: Allows system reset to default IP (192.168.1.254) by pressing a button for 0.5 seconds.
Protocol Configuration
  • Configuration Acquisition Channel: Use Odot Configuration Software to scan devices and configure collection channels for data acquisition from PLCs.
  • Publish Channel Creation: Collection points can be automatically or manually published to Modbus TCP or MQTT channels. Configuration includes setting IP addresses, port numbers, and data parameters.
  • MQTT Configuration: Involves setting server parameters, device parameters, and communication parameters for publishing and subscribing to topics.
Configuration File Management
  • After configuring collection and distribution points, configurations can be downloaded to the gateway. Options for uploading, importing, and exporting configurations are available.
Gateway IP Address Configuration
Ensure the IP address is set correctly. If the gateway IP address is forgotten, it can be reset to the default factory IP address using the reset key. It is important that the computer and gateway are on the same network segment for downloading and uploading.
Modbus Poll Software Testing
To test using the MODBUS POLL software, open the software and navigate to the Connection/Connect menu. Input the gateway IP address as 192.168.1.100 and set the Server Port to 502, then click OK. For reading and writing definitions, select function code 03 and confirm by clicking OK.
Contact Information
Odot Automation System Co., Ltd.
Address: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China.
Tel: +86-0816-2538289
Zip Code: 621000
Email: [email protected]
Website: www.odotautomation.com
See more

Catalog excerpts

MG-IOT03 User Manual_V1-1

od-t Sichuan Odot Automation System Co., Ltd S7-TCP to MODBUS-TCP and MQTT Gateway MG-IOT03 User Manual ODOT Automation System Co., Ltd. 2019-06 Copyright ©2019 ODOT Automation all rights reserved http:// www.odotautomation.com

 Open the catalog to page 1
MG-IOT03 User Manual_V1-2

ocM Sichuan Odot Automation System Co., Ltd Version information The following changes have been made to the document: Ownership rights information Without the permission of the copyright owner, all or part of this document shall not be republished as a paper or electronic document. Disclaimer This document is only intended to assist the reader in using the products, and the company shall not be responsible for any loss or error caused by the use of the information in this document. The product and text described in this document are under constant development and refinement. ODOT Automation System...

 Open the catalog to page 2
MG-IOT03 User Manual_V1-3

http:// www.odotautomation.com

 Open the catalog to page 3
MG-IOT03 User Manual_V1-4

ocM Sichuan Odot Automation System Co., Ltd 1. Product overview 1.1. Introduction MG-IOT03 is an industrial-grade Ethernet gateway with protocol conversion functions; it carries with 5*100Mbps ports, all of which support 10/100Mbps auto-negotiation and Auto-MDI /MDIX. The gateway could convert Siemens S7 Ethernet protocol to Modbus TCP and MQTT through ODOT software configuration. 1.2. Function Introduction ♦ It supports Siemens S7 Ethernet to MODBUS-TCP and MQTT protocols ♦ It supports Auto negotiation 10/100Mbps, half/full duplex, Auto MDI/MDIX Supports 200 collection points ♦ It supports equipment...

 Open the catalog to page 4
MG-IOT03 User Manual_V1-5

1.3.Technical parameters Environmental Parameters Operating temperature Storage temperature Working humidity Power Supply Power ports no. Input voltage Power consumption Ethernet parameters Ethernet port number Network protocols PLC number collected simultaneously Number of data points supported -40~85℃ -55~125℃ 5%~95% (no condensation)) 1 port 9~36V DC Max.200mA@24V 5 RJ45, 10M, 100M adaptive rate, with gateway function ETHERNET、ARP、IP、TCP、 ICMP、MQTT Max. 4pcs 200 http:// www.odotautomation.com

 Open the catalog to page 5
MG-IOT03 User Manual_V1-6

od-t Sichuan Odot Automation System Co., Ltd 2.2. Indicator light description 2.4. A one-key reset In order to facilitate the use of customers, the gateway has set the function of one-key reset, which is located in the round hole at the bottom of the gateway. The system reset can be achieved by pressing the button for about 0.5 seconds. After reset, the default gateway IP is 192.168.1.254 http:// www.odotautomation.com

 Open the catalog to page 6
MG-IOT03 User Manual_V1-7

2.5. Installation dimensions http:// www.odotautomation.com

 Open the catalog to page 7
MG-IOT03 User Manual_V1-8

3.Siemens S7 Ethernet to Modbus-TCP and MQTT protocols 3.1 Create a configuration acquisition channel Please open "Odot Configuration Software" and select Tool →Scan Device Click Scan device in the device Search dialog box, and click OK when finished. Lighting tests could be performed on modules; this could distinguish multiple MG-IOT03 modules in the same network. Double-click "MG-IOT03-S7" in the project bar, and the "Network Port" window and parameters of the gateway pop up on the right side. http:// www.odotautomation.com

 Open the catalog to page 8
MG-IOT03 User Manual_V1-9

The main parameters have the following meanings: IP address: Gateway IP, the gateway creates Modbus TCP server IP, and the user accesses this IP address and port 502 to log in Modbus TCP server. Right-click "Collection channel" in the project bar and select Add S7(Ethernet) protocol. Under the drop-down menu, appear "S7(Ethernet)_1." http:// www.odotautomation.com

 Open the catalog to page 9
MG-IOT03 User Manual_V1-10

Click "S7(Ethemet)_1" and the configuration channel parameters and configuration collection point window will pop up on the right. In the configuration channel parameters window, PLC IP is the IP address of the actual PLC, and the port number is fixed as 102. Click "Configure collection point" and add read or write commands in the "Add Collection Point" column. Collection channel config /I Collection point config * Collection channel Collection point Command name Collection point name Delete Copy Parameter name Parameter va ue Pub ish channe Automatic publish Automatic publish: Disable Command...

 Open the catalog to page 10
MG-IOT03 User Manual_V1-11

od-t Sichuan Odot Automation System Co., Ltd column. For example, the collection point CPoint 1 reads the command, could set to read the PLC internal data register area, starting address, data offset bit, data type, Enable trigger mode, calculation and other parameters. m IOT gateway configuration softwar ollection channel config / Collection point config * Collection channel Collection point Command name Collection point name Delete Parameter name Publish channel Delete Copy&Paste Collection Point Name CPoint 1 Delete Copy&Paste Delete Copy&Paste Register Area Delete Copy&Paste Delete Copy&Paste...

 Open the catalog to page 11
MG-IOT03 User Manual_V1-12

OCf-t Sichuan Odot Automation System Co., Ltd enable: To send a command to the PLC when there is a data change. Disable: Write command loop sent to PLC. Calculation: no operation (Multiplication/Division: Calculated value = base + multiplier (* or /) collected value) Base: Same as above Multiple rate: Same as above Store data type sort: The default is Little-endian in front; there are other data word, double word, floating point sort type optional. Store data type: The data type of the data store, such as PLC data type is INT, store data type float, and the data will have type conversion. 3.2....

 Open the catalog to page 12
MG-IOT03 User Manual_V1-13

http:// www.odotautomation.com

 Open the catalog to page 13
MG-IOT03 User Manual_V1-14

od-t Sichuan Odot Automation System Co., Ltd 3.2.2 Manual release of collection points Right-click the publishing channel in the left "Project bar" and select the publishing channel to be added. There are two options, Modbus TCP channel and MQTT channel. http:// www.odotautomation.com

 Open the catalog to page 14
MG-IOT03 User Manual_V1-15

3.2.2.1 Manual Modbus TCP channel configuration Click Modbus TCP channel, Modbus TCP server parameters can be configured, port number default 502, watchdog enable or disable, and watchdog time. Click "Configure Publish Point" and select "Add read and write command" in the "Add Publish point" bar. Configuring the publishing point name, Modbus register area, and starting address in the Parameters column. Then select the associated collection channel, the collection point, and click the associated point. Figure: Add a read command, release point name is RPoint 1, publish to 40001 address, collect...

 Open the catalog to page 15

All ODOT Automation catalogs and technical brochures

  1. C3351

    8  Pages

  2. BOXIO 64

    4  Pages

  3. PLC

    59  Pages

  4. CN-8034

    2  Pages

  5. CN-8033

    2  Pages

  6. CN-8032

    2  Pages

  7. CN-8012

    2  Pages

  8. CN-8011

    2  Pages

  9. CN-8031

    2  Pages

  10. CT-7221

    17  Pages

  11. CT5800

    15  Pages

  12. CT4234

    20  Pages

  13. CT3804

    21  Pages

  14. CT-3713

    19  Pages

  15. CT3238

    19  Pages

  16. CT-3158

    19  Pages

  17. CT2718

    18  Pages

  18. CT2228

    18  Pages

  19. CT623F

    23  Pages

  20. CT-222F

    19  Pages

  21. CT-121F

    21  Pages

  22. ODOT-S7PPIV2.0

    31  Pages

  23. ODOT-PNM02

    31  Pages

  24. ODOT-S4E2

    56  Pages

  25. ODOT-IOT01

    79  Pages

  26. ODOT-IOT02

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.