

Catalog excerpts

od*t Odot Automation System Co., Ltd http:// www.odotautomation.com
Open the catalog to page 1
Od»t Odot Automation System Co., Ltd Odot Automation System C°., Ltd* 2020-2 Copyright ©2020 Odot Automation all rights reserved http:// www.odotautomation.com
Open the catalog to page 2
Ownership rights information Without the permission of the copyright owner, all or part of this document shall not be republished as a paper or electronic document. Disclaimer This document is only intended to assist the reader in using the products, and the company shall not be responsible for any loss or error caused by the use of the information in this document. The product and text described in this document are under constant development and refinement. Odot Automation System Co., Ltd. has the right to modify this document without notifying users. Software download Please log on the...
Open the catalog to page 3
od*t Odot Automation System Co., Ltd http:// www.odotautomation.com
Open the catalog to page 4
1 Product Overview Remote IO system consists of network adapter module and extended IO module. The network adapter module controls fieldbus communication and it realizes communication link with host station controller or host computer software. The extended IO module controls the connection with the input and output sensors in the field. At first the Input IO module collects the field signals and sends it to the network adapter through the internal bus. Secondly the controller reads and processing data from the adapter through the field bus, and it writes the output data into the network...
Open the catalog to page 5
od*t Odot Automation System Co., Ltd High speed backplane bus, the refresh cycle of 32 modules is 1ms. • The channels carry with Complete ODOT status indicator lights. self-design. Multiple input/output modules: DI/DO, AI/AO, special modules, extended power modules. Terminal Module 1.2 Module Layout The ODOT-C series is a remote I/O module. The adapter module lies on the far left, and on the right are extended I/O modules. http:// www.odotautomation.com
Open the catalog to page 6
1.3 LED Indicators The user can easily check the power state of adapter and I/O module, I/O module operating state, and the number of I/O channels though LED state. And the detailed indicator state should refer to the related adapter or IO modules. 1.4 Ground Protection There is one metal resilient sheet on the back of the module, which is used for effective grounding with the guide rail. The metal resilient sheet and the adapter PE (protective earthing) are connected internally.
Open the catalog to page 7
Use push-in method to connect single-wire or crimp terminal wires without any other tools. Users can save wiring time and ensure a safe operation regardless of wiring experience. The module equips with a wiring fixed end for cable harness, which is used to fix the cable when the IO module is wired with multiple cables. 1.6 Installation and Removal DIN-Rail Lock could be safely and reliably installed on 35 mm DIN-Rail. There is a manual closure buckle on the upper side of all modules for locking, and a manual buckle is on the left side of the adapter for locking the guide rail. http://...
Open the catalog to page 8
When the module is removed, it needs to manually unlock the guide rail on the upper side of the module. For the adapter module, you also need to unlock the left rail buckle counterclockwise.
Open the catalog to page 9
od*t Odot Automation System Co., Ltd Adapter size: 115*51.5*75mm I/O module size: 115*14*75mm 2 Extended IO module CT-2718: 8 channel relay output 2A/30VDC/60W 1 Module features ♦ 8-channel relay normally on output ♦ 8 LED channel indicators ♦ Low on resistance (<100mQ) ♦ 250VAC/220VDC the max. switch voltage is 250VAC/220VDC http:// www.odotautomation.com
Open the catalog to page 10
od*t Odot Automation System Co., Ltd http:// www.odotautomation.com
Open the catalog to page 11
© Module Type © State indicator © N/A © Wiring Terminal and identification © Internal Bus © Field Power © Buckle © Grounding Resilient Sheet @ Fixed Wiring Harness
Open the catalog to page 12
© Power LED indicator (red) © Module State LED indicator (red/green) © Output channel LED indicator (green) http:// www.odotautomation.com
Open the catalog to page 13
od*t Odot Automation System Co., Ltd http:// www.odotautomation.com
Open the catalog to page 14
od*t Odot Automation System Co., Ltd 4 Wiring http:// www.odotautomation.com
Open the catalog to page 15
Data description: Fault Action for Output Ch#(0-7): Fault output mode. When IO module detects that internal bus communication is failed and enters offline mode, the output data will be processed in this mode. (Default: 0) 0: Hold the last output state. 1: Output fault value Fault Value for Output Ch#(0-7): When the fault output mode is 1, this bit would set the fault output value, and when the internal bus of IO module is offline,
Open the catalog to page 16
od*t Odot Automation System Co., Ltd this setting value will be output.(Default: 0) 0: Output low level. 1: Output high level. http:// www.odotautomation.com
Open the catalog to page 17
______________________________________________________________ Odot Automation System Co., Ltd. Add: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Tel: +86-0816-2538289 Zip Code: 621000 Email:sales@odotautomation.com Web: www.odotautomation.com http:// www.odotautomation.com
Open the catalog to page 18All ODOT Automation catalogs and technical brochures
-
C3351
8 Pages
-
ODOT C series remote IO
4 Pages
-
BOXIO 64
4 Pages
-
ODOT remote IO catalogue
20 Pages
-
PLC
59 Pages
-
New small ODOT brochure
16 Pages
-
CN-8034
2 Pages
-
CN-8033
2 Pages
-
CN-8032
2 Pages
-
CN-8012
2 Pages
-
CN-8011
2 Pages
-
CN-8031
2 Pages
-
Remote I/O C Series
376 Pages
-
ODOT-MS100T Serial User Manual
15 Pages
-
Remote I/O module
36 Pages
-
CT-7221
17 Pages
-
CT5800
15 Pages
-
CT4234
20 Pages
-
CT3804
21 Pages
-
CT-3713
19 Pages
-
CT3238
19 Pages
-
CT-3158
19 Pages
-
CT2228
18 Pages
-
CT623F
23 Pages
-
CT-222F
19 Pages
-
CT-121F
21 Pages
-
ODOT-PNM02 User Manual_V1.5.
37 Pages
-
MG-IOT03 User Manual_V1
24 Pages
-
ODOT-IOT02
44 Pages
-
ODOT AIOBOX - Integrated IO module
149 Pages
-
ODOT-S7PPIV2.0
31 Pages
-
ODOT-PNM02
31 Pages
-
ODOT-S4E2
56 Pages
-
ODOT-IOT01
79 Pages
Archived catalogs
-
ODOT-S1E1 User Manual 20200720
30 Pages