od-t Sichuan Odot Automation System Co., Ltd http: // www.odotautomation.com
Open the catalog to page 1
Power Supply: 9-36 VDC Operating Temperature -40-85:C Humidity: 5-95%RH (non-condensing i LED Status PWR Power status DF Device Fault RUN Modbus RUN ERR Communcaion Error IRN 10 RUN Nr. Not Used Sichuan Odot AUonwtk>n s>«enn Co. Uld http: /i'www.odot.cn Tel’QQ: 400-1024-^35 Sichuan Odot Automation System Co., Ltd 2019-6 Copyright©2010 All rights reserved by Odot Automation http: // www.odotautomation.com
Open the catalog to page 2
od-t Sichuan Odot Automation System Co., Ltd Ownership information Without the consent of the copyright owner, part or all of this document are not allowed to be republished in paper or electronic document. Disclaimer This document shall only be used to assist readers for the using of our products and the company shall not be responsible for any loss or error caused by the information in this document. The text and product described in this document is constantly developing and improving. Sichuan Odot Automation System Co., Ltd. has the right to modify this document without notifying users....
Open the catalog to page 3
http:// www.odotautomation.com
Open the catalog to page 4
Od*t Sichuan Odot Automation System Co., Ltd 1 Product Overview 1.1 Product Introduction MiniBox series IO module: AIO-MT623F is an Ethernet based integrated IO module, with 8 input channels and 8 output channels. This product supports the use of RS485 interface (Modbus-RTU) and Ethernet interface (Modbus-TCP) for communication, and supports the simultaneous access of 5 Modbus TCP clients. It is simple and convenient to use with stable transmission, full metal shell and strong anti-interference ability. The internal PCB adopts anti-corrosion technique including anti-corrosion,...
Open the catalog to page 5
od-t Sichuan Odot Automation System Co., Ltd http: // www.odotautomation.com
Open the catalog to page 6
od-t Sichuan Odot Automation System Co., Ltd http: // www.odotautomation.com
Open the catalog to page 7
Power Input and RS485 Channel Product Name: AI0B0X10 Module Product Series: MmiBOX Product Model: AIOBOX-MT623F Power Supply: 9~36VDC Operating Temperature -40~85=C Humidity 5~95%RH (non-cordensrgi LED Status PWR Paver status DF Device Fadt RUN Modbus RUN ERR Common cation Error |RN 10 RUN NC Not Used Sichuan Odot Automation System C:.L!:! hap /,www.odot.cn / http: // www.odotautomation.com
Open the catalog to page 8
od-t Sichuan Odot Automation System Co., Ltd 2.3 System Power and Communication Interface A, System Power and Communication Ports Definition It supports standard Modbus-TCP and Modbus-RTU/ASCII protocol access. The Ethernet supports cascade function of dual Ethernet port switch, and the serial port supports RS485 bus connection mode. http: // www.odotautomation.com
Open the catalog to page 9
od-t Sichuan Odot Automation System Co., Ltd http: // www.odotautomation.com
Open the catalog to page 10
od-t Sichuan Odot Automation System Co., Ltd http:// www.odotautomation.com
Open the catalog to page 11
od-t Sichuan Odot Automation System Co., Ltd
Open the catalog to page 12
od-t Sichuan Odot Automation System Co., Ltd Dada description: MAC Address [0-5]: Device MAC address (read only) IP Address[0-3]: Device IP address (Default: 192.168.1.100) Net Mask[0-3]: Device subnet mask (Default: 255.255.255.0) Net Gateway[0-3]: Device subnet gateway (Default: 192.168.1.1) Modbus Port: Modbus Port no. (Default: 502) Effective range: 0-65535 Watchdog Enable: Modbus Watchdog enable (Default: 0: Watchdog disabled 1 : Watchdog enabled Watchdog Time(s): Watchdog time (Default: 10) Effective range: 1-65535 Slave ID: Modbus AA ID A(Default: 1) Effective range: 1-247 Baud rate:...
Open the catalog to page 13
od-t Sichuan Odot Automation System Co., Ltd 0: No parity 1: Odd 2: Even Stop Bits: stop bit (Default: 1) 1: 1 stop bit 2: 2 stop bit Serial Mode: serial mode (Default: 0) 0: RTU mode 1: ASCII mode Char Pitch: inter-frame space (Default: 2) 0: 1.5t 1: 3.5t 2: 5t 3: 10t 4: 20t 5: 50t 6: 100t 7: 200t Respond Delay: Slave station replying delay time (Default: 0) http:// www.odotautomation.com
Open the catalog to page 14
od-t Sichuan Odot Automation System Co., Ltd unit ms (Default: 10) of a channel count value Data description: Input Filtering Time(ms): channel input filtering time, Counter Value Data Format: The byte transfer sequence (Default: 0) 0: A-B-C-D 1: B-A-D-C 2: C-D-A-B 3: D-C-B-A Input Holding Time(ms): input holding time, unit ms(Default: disable) Storage Enable: storage enabled (Default: disable) Count Mode Ch#(0-15): input channel count mode (Default: 0) 0: Rising edge count 1 : Falling edge count 2: Double edge count Count Direction Ch#(0-15): input channel count direction (Default: 0) 0:...
Open the catalog to page 15
od-t Sichuan Odot Automation System Co., Ltd 2.6 Installation Dimension The 16-channel digital output module AIobox-MT623F supports the installation of Din-rail, which is simple and convenient to install and easy to operate. Its working temperature is -40 ~ 85°C and the humidity are within the range of 5 ~ 95% RH, and the module would be greatly affected if this scope is beyond. Product Name: AI0B0X10 Module Product Series: MiniBOX Product Model: AIOBOX-MT623F Power Supply: 9~36 VDC Operating Temperature -40~85:C Humidity 5~95%RH (non-condensingi LED Status PWR Paver status DF Device Fault...
Open the catalog to page 16
3 Configuration Software Usage 1. Powering on the module and connecting the module to the computer with the network cable then double-click my computer. And it needs to open the network and sharing center under the control panel, and sets the computer IP and the gateway IP in the same network segment. For example, if the gateway default IP is 192.168.1.100 and the computer IP should be 192.168.1. (1~ 99, 101-254). 2. After installing AIO-Box config software, opening the configuration software, clicking File → Project → New Project in the menu bar, or right clicking Project → New Project in...
Open the catalog to page 17
3. In the project directory bar, right-clicking the Project Name → Upload IO module, and selecting scan module in the pop-up dialog box, selecting local network card, and clicking Search Device to scan AIO-MT623F module. http: www.odotautomation.com //
Open the catalog to page 18
od-t Sichuan Odot Automation System Co., Ltd Select interface; SerialPort Network Card;| 2:1 ntel(R) 32579LM Gigabit Network Connection #2 192,168.1.16 " | Subnet mask Gateway address Indicator light control Parameter Lighting twinkle Search Device were seal 4. When there are multiple modules in the network structure, the Multiple Devices could be popped up on the scanning interface. And IP address could be directly modified on this interface, and then the actual modules in the site could be located by clicking the Lighting twinkle. http: // www.odotautomation.com
Open the catalog to page 19All ODOT Automation catalogs and technical brochures
-
C3351
8 Pages
-
ODOT C series remote IO
4 Pages
-
BOXIO 64
4 Pages
-
ODOT remote IO catalogue
20 Pages
-
PLC
59 Pages
-
New small ODOT brochure
16 Pages
-
CN-8034
2 Pages
-
CN-8033
2 Pages
-
CN-8032
2 Pages
-
CN-8012
2 Pages
-
CN-8011
2 Pages
-
CN-8031
2 Pages
-
Remote I/O C Series
376 Pages
-
ODOT-MS100T Serial User Manual
15 Pages
-
Remote I/O module
36 Pages
-
CT-7221
17 Pages
-
CT5800
15 Pages
-
CT4234
20 Pages
-
CT3804
21 Pages
-
CT-3713
19 Pages
-
CT3238
19 Pages
-
CT-3158
19 Pages
-
CT2718
18 Pages
-
CT2228
18 Pages
-
CT623F
23 Pages
-
CT-222F
19 Pages
-
CT-121F
21 Pages
-
ODOT-PNM02 User Manual_V1.5.
37 Pages
-
MG-IOT03 User Manual_V1
24 Pages
-
ODOT-IOT02
44 Pages
-
ODOT AIOBOX - Integrated IO module
149 Pages
-
ODOT-S7PPIV2.0
31 Pages
-
ODOT-PNM02
31 Pages
-
ODOT-S4E2
56 Pages
-
ODOT-IOT01
79 Pages
Archived catalogs
-
ODOT-S1E1 User Manual 20200720
30 Pages