Technical Specifications
  • Body Material: Stainless Steel AISI 316
  • Armature Tube: Stainless Steel AISI 300 series
  • Plungers: Stainless Steel AISI 400 series
  • Spring: Stainless Steel AISI 300 series
  • Housing: Ex d Housing in Aluminium die cast
  • Media Compatibility: Mineral oils, gasoline, diesel, fuel oils, air, inert gases, water, 134a, R404a
  • Temperature Ranges:
    • Ex m Ambient: Refer to coils catalogue
    • Ex m Fluid: -10°C to +80°C with FKM seals
    • Ex d Ambient: -40°C to +60°C
    • Ex d Fluid: -30°C to +80°C with H-NBR seals, -10°C to +140°C with FKM seals
  • Design Pressure: 25 bar
  • Protection Class: Ex m IP65, Ex d IP65
  • Electrical Conformity: IEC 335
  • Switching Time: 20-40 msec
  • ATEX Compliance: Directive 94/9/CE ATEX
Installation
  • Mounting: Can be mounted in any position
  • Documentation: Maintenance and instruction sheet included
  • Fuse Selection: Refer to the instruction sheet provided
  • Fixing: Holes and threaded connections available for panel fixing
Repair Kit and Accessories
  • Repair Kit: Consult technical department for spare parts
  • Accessories: Cable Gland (Code P992219) to be ordered separately
Features
  • Dedicated to CPT Market
  • Explosion Proof Rating
  • Reliable Construction
Dimensional and Performance Data
  • Pipe Sizes: G 1/2, G 3/4, G 1
  • Coil Types: Various voltage options available
  • Pressure and Viscosity: Detailed specifications for each model
See more

Catalog excerpts

21X Ex m, Ex d N.C.-1

FEATURES 4 Dedicate to CPT Market 4 Explosion proof rate 4 Reliable construction (*) Ex d protection class when assembled with Ex housing 92 Atex - Solenoid valve 2/2 way With pilot control Explosion proof TECHNICAL SPECIFICATION 4 Body material: Stainless Steel AISI 316 4 Armature tube: Stainless Steel AISI 300 series 4 Plungers: Stainless Steel AISI 400 series 4 Spring: Stainless Steel AISI 300 series 4 Ex d Housing in Aluminium die cast 4 Media: mineral oils, gasoline, diesel, fuel oils, air inert gases, water, 134 a, R 404a 4 Ex m Ambient temperature: See coils catalogue page for its compatibility 4 Ex m Fluid temperature: -10°C +80°C with FKM seals 4 Ex d Housing Ambient temperature: -40°C +60°C 4 Ex d Fluid temperature: -30°C +80°C with H-NBR seals -10°C +140°C with FKM seals 4 Design pressure PS: 25 bar 4 Protection class: Ex m IP65 (complete with electric plug) Ex d IP 65 (with hosing fitted by cable gland Atex Ex d) 4 Electrical conformity: IEC 335 Switching time: 20-40 msec (depending on pressure conditions) (conforme to Atex Directive 94/9/cE ATEX) For S.V. 21X2Q.. II 2G Ex mb IIC Gb II 2D Ex tb IIIC t130°C Db For S.V. 21X2KI.. II 2G Ex d IIC t6 o t5 Gb II 2D Ex bb IIIC T80°C o T95°C Db (Tamb: -40°C < +60°C) REPAIR KIT For spare parts please consult our technical department Coil P/N Ex mb II T 4 RTNA4X024D4 RTNA5X110D4 RTNA05224DA RTNA10024C4 REPAIR KIT For spare parts please consult our technical department ACCESSORIES Code P992219 Cable Gland (to be ordered separately) INSTALLATION 4 The solenoid valves can be mounted in any position 4 Maintenance and instruction sheet available in each solenoid valve box 4 Attention: for fuse selection please refer to the “Instruction sheet Atex products” delivered together with the valve 4 Holes and threaded connections for panel fixing

 Open the catalog to page 1

All ODE catalogs and technical brochures

  1. PX50 Series

    1  Page

  2. 31Z N.C.

    1  Page

  3. 31A N.C.

    1  Page

  4. 31JN N.C.

    1  Page

  5. 21T N.C.

    1  Page

  6. 21A series

    38  Pages

  7. 21IA-5 Series

    2  Pages

  8. 21IA4T

    8  Pages

  9. 21IA series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.