1. Catalogs
  2. OAKTON
  3. Cole-Parmer®loop powered chlorine and chlorine dioxide sensors

Cole-Parmer®loop powered chlorine and chlorine dioxide sensors

Cole-Parmer®loop powered chlorine and chlorine dioxide sensors

Cole-Parmer®loop powered chlorine and chlorine dioxide sensors

Product catalog summary
Overview
The document describes an economical measurement system designed for safer drinking water, focusing on chlorine dioxide and free chlorine sensors. These sensors are amperometric with a 4 to 20 mA output, offering multiple ranges for enhanced accuracy. The system includes a flow cell that creates a vortex for consistent results, providing real-time, online measurements with automatic temperature compensation and signal conditioning.

Specifications
- Chlorine dioxide sensors measure 0 to 2 or 0 to 10 ppm, with some cross-sensitivity to ozone.
- Free chlorine sensors measure 0 to 2, 0 to 5, or 0 to 10 ppm, with cross-sensitivity to ozone, bromine, iodine, chlorine dioxide, chloramines, and bromamine.
- The sensors have a service life exceeding one year in most applications, with replacement parts available to reduce ownership costs.
- Sensor cable length is 10 feet.

Applications
The system is ideal for water treatment disinfection, measuring chemicals during the treatment process, and verifying proper amounts of residual chlorine dioxide or free chlorine.

Technical Assistance
Free technical applications assistance is available in the UK, US, Canada, and India, with contact details provided for each region.

Accessories
- ML-94785-12 Panel meter; 115 V
- ML-99672-05 Flow cell, 3⁄4" NPT(F) inlet and outlet
- ML-99672-10 Replacement sensor fill solution; chlorine dioxide, 60 mL
- ML-99672-12 Replacement membrane cap; chlorine dioxide and free chlorine
- ML-99672-14 Replacement sensor fill solution; free chlorine, 60 mL

Performance Details
- Accuracy: ±5% full-scale
- Temperature compensation: Automatic
- Maximum pressure: 14.7 psi (1 bar)
- Flow range: 8 to 26 GPH (30 to 98 LPH), ideal 11 to 16 GPH (40 to 60 LPH)
- Output: 4 to 20 mA
- Power: 16 to 24 VDC, 35 mA minimum
- Housing: PVC
- Dimensions: 35⁄16"W x 11"H x 5⁄8"D
See more

Catalog excerpts

Cole-Parmer®loop powered chlorine and chlorine dioxide sensors-1

Chlorine Dioxide and Free Chlorine Sensors Economical Measurement System For Safer Drinking Water • Amperometric sensor with 4 to 20 mA output • Multiple ranges available for greater accuracy • Flow cell produces vortex for consistent results These sensors provide real-time, on-line measurements provided as a 4 to 20 mA output for user flexibility on the interface instrumentation. Sensors have automatic temperature compensation (ATC) and signal conditioner for accurate results over the entire measurement range. Purchase a complete system (sensor and flow cell), or purchase only sensors to use as replacements for existing installatio

 Open the catalog to page 1
Cole-Parmer®loop powered chlorine and chlorine dioxide sensors-2

tr/J Cole-Pa rmer scientific experts In the U.S. In Canada 625 E. Bunker Court Call toll-free 800-363-5900 Vernon Hills, IL 60061 Phone: 514-355-6100 Call toll-free 800-323-4340 Fax: 514-355-7119 www.coleparmer.com In India In the United Kingdom Free phone: 0500-345-300 Phone: 020-8574-7556 Fax: 020-8574-7543 www.coleparmer.co.uk International customers Call 847-549-7600 to reach our International Sales Department or contact your local dealer. FREE TECHNICAL APPLICATIONS ASSISTANCE! Applications Water treatment disinfection—these systems are ideal for measurement of chemicals during...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.