Vaneaxial Fixed Pitch Fans
16Pages

{{requestButtons}}

Catalog excerpts

Vaneaxial Fixed Pitch Fans - 1

BELT DRIVE VANEAXIAL FIXED PITCH FANS • Capacities to 100,000 CFM • Static pressures to 9”WG • Temperatures to 200°F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-5530 Visit us on the Web: http://www.nyb.com Phone: (800) 208-7918 Email: nyb@nyb.com

Open the catalog to page 1
Vaneaxial Fixed Pitch Fans - 2

VANEAXIAL FANS Vaneaxial Fixed Pitch Fans are designed and constructed for high pressure ventilating and industrial process applications requiring the compactness of an axial fan. • Capacities – to 100,000 CFM. • Pressures – to 9” WG. Fifteen belt-drive sizes – 12” through 60” wheel • diameters. DESIGN FEATURES Multiple • selection hub ratios are available – for increased flexibility. • Choice of belt-drive configurations – belt drive in five mounting positions. rolled tube – for • Precision and maximum efficiency.minimum clearance Arrangement 9-D with access door, motor, V-belt drive, and...

Open the catalog to page 2
Vaneaxial Fixed Pitch Fans - 3

9-M Mounting Positions viewed from discharge end Fabricated mounting legs facilitate fan mounting on the floor, ceiling, or in a vertical position on a wall. Flange connections are standard. Fans are equipped with four mounting brackets suitable for floor, platform, or ceiling mounting. Motor is located on centerline between two of the four brackets. Flange connections are standard. Units feature flanges on inlet and discharge for mounting to the duct work. Roof-mounted fans are furnished with curb caps and collars extending below the curb cap for easy connection. Stackhoods and weather...

Open the catalog to page 3
Vaneaxial Fixed Pitch Fans - 4

ACCESSORIES AND MODIFICATIONS 1. INLET BELL WITH GUARD Arrangement 9-M with inlet bell with guard, weather cover, motor, and V-belt drive. Inlet bell minimizes losses associated with non-ducted inlet applications. Includes wire guard. 2. VIBRATION ISOLATION – not shown Rubber-in-shear or spring-type isolation mounts reduce the transmission of vibration to the mounting structure. 3. SAFETY EQUIPMENT/WEATHER COVER Belt guards are included as standard. Inlet and outlet guards, and louvered weather covers are available. Selection of appropriate safety accessories is the responsibility of the...

Open the catalog to page 4
Vaneaxial Fixed Pitch Fans - 5

INLET BELL Catalog ratings shown in this bulletin are for Vaneaxial Fixed Pitch Fans with free inlet and ducted outlet. When no inlet duct is used, entrance loss must be added to the static pressure calculated for the system. For bare inlets, that loss is equal to the fan velocity pressure. Example: 4200 FPM velocity = 1.1 "WG [see Chart I at right]. Inlet bells render such loss negligible and are available at nominal cost. Sizes 12 through 48 constructed of fiberglass reinforced plastic; Sizes 54 and 60 constructed of steel. Available for all sizes of Vaneaxial Fixed Pitch Fans with...

Open the catalog to page 5
Vaneaxial Fixed Pitch Fans - 6

For a given fan size, CFM, and static pressure, capacity tables can be used to obtain outlet velocity, fan RPM, and BHP If capacities are at conditions other than 70°F, sea level, or standard density [.075 lb./cu. ft.], correction factors must be applied to static pressure and BHP Chart II details maximum safe speed of standard wheels at 70°F. When temperatures are involved, multiply the appropriate safe operating speed shown in Chart II by the factor shown in Chart III. Maximum operating temperature for standard fans is 120°F. For temperatures above 120°F, as indicated by tinted areas in...

Open the catalog to page 6
Vaneaxial Fixed Pitch Fans - 7

Belt-Drive Vaneaxial Fixed Pitch Fans Belt-drive Vaneaxial Fixed Pitch Fans are available in Sizes 12 through 60. Standard Design is provided less a belt well for improved airflow performance and efficiencies. For applications requiring sealed drives, spark-resistant construction, or temperatures in the range of 120 to 200 degree F, fans can be furnished with an optional belt well to isolate the bearings and drive components from airborne moisture and contaminants. In the event that system pressures or flow requirements change, belt-drive Vaneaxial fans offer inherent performance...

Open the catalog to page 7
Vaneaxial Fixed Pitch Fans - 8

Performance certified is for installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

Open the catalog to page 8
Vaneaxial Fixed Pitch Fans - 9

Performance certified is for installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

Open the catalog to page 9
Vaneaxial Fixed Pitch Fans - 10

Performance certified is for installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

Open the catalog to page 10
Vaneaxial Fixed Pitch Fans - 11

Performance certified is for installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

Open the catalog to page 11
Vaneaxial Fixed Pitch Fans - 12

Performance certified is for installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Fan Access Section Optional Fan Access Section can be mounted to the fan's inlet or outlet and allows access to the fan wheel, bearings, shaft and driven sheave. Panel behind removable door is partially cut and requires grinder to cut fixturing tabs before gaining access.

Open the catalog to page 12
Vaneaxial Fixed Pitch Fans - 13

Material Specifications Dimensions in inches. Weights in pounds. WR2 in lb.-ft.2. Tolerance: ±Vfe" * Shaft diameter at bearings is 115/16" with a 111/16" turndown at the wheel for the PI bushing. Bearing types: A-Standard D-Lok B-Medium D-LOK C-Link-Belt 22400 Series. All Sizes:Flange bearings Bearings: For fan sizes 12-06-06 through 21-08-09 both bearings are fixed. For fans sizes 21-12-12 through 60-26-09, the non-drive bearing is fixed and the drive bearing is expansion. nyb reserves the right to substitute bearings of equal quality. Wheel weight includes bushing. t9R weights are for fan...

Open the catalog to page 13
Vaneaxial Fixed Pitch Fans - 14

FAN FLANGE DIMENSIONS Size Maximum frame sizes are listed per size. *siots spaced equally, straddling centerline. INLET BELL DIMENSIONS Material Specifications Dimensions in inches. Tolerance: ±18" INLET VANE DAMPER DIMENSIONS Size

Open the catalog to page 14

All NYB catalogs and technical brochures

  1. Silencers

    3 Pages

  2. Vaneaxial Fans

    20 Pages

  3. Tubeaxial Fans

    16 Pages

  4. Duct Fans

    16 Pages