Overview: This technical bulletin from The New York Blower Company provides detailed information on duct fans, including specifications, construction and design features, application advantages, and available accessories. It also covers various fan types such as Vaneaxial, Tubular Acoustafoil, and Tubeaxial fans.
Specifications: Duct fans have capacities up to 60,000 CFM and can handle static pressures up to 2”WG. They are capable of operating at temperatures up to 350°F.
Construction Features: The fans feature steel wheels with curved blades for efficiency, heavy-gauge welded components for durability, and bearings with a minimum L-10 life of over 50,000 hours. Additional features include an industrial finish, flanged connections, lifting eyes, and extended lubrication lines.
Design Features: The design includes 13 sizes with wheel diameters ranging from 12” to 60”, and options for direct-drive or belt-drive in five mounting positions. The precision-rolled tube design ensures maximum efficiency.
Application Advantages: Duct fans are ideal for low-pressure ventilation and industrial exhaust applications. Their compact design offers space-saving benefits and they are interchangeable with Tubeaxial and Vaneaxial fan lines.
Accessories and Modifications: Available accessories include inlet bells, vibration isolation mounts, safety equipment, and weather covers. Modifications can include spark-resistant construction and alternate material options.
Safety and Performance: Proper installation and maintenance are crucial for safe operation. The document advises selecting appropriate safety accessories and emphasizes the need for guards on exposed moving parts.
Mounting Arrangements: Various mounting options are available, including floor, ceiling, vertical, suspended, duct, and roof mounting, each designed to meet specific installation needs.
Performance Charts: Charts are provided for velocity pressure, maximum safe speeds, and correction factors for temperature and altitude, aiding in fan selection and operation under different conditions.
Direct-Drive Duct Fans: These fans, available in sizes 127 through 547, are suitable for clean-air applications at temperatures up to 105°F and offer reduced maintenance due to the elimination of external motor mounting structures.
Product Categories: The document also outlines various product categories offered by the company, including Dust/Material Handling, Roof Ventilators, Process/Fan Components, Heating Products, Air-Handling (Centrifugal and Axial), Fiberglass Reinforced Plastic (FRP), and Custom Products.
Key Features: The company emphasizes its ability to provide customized solutions and a wide selection of air-moving equipment to meet diverse industrial needs.
See more

Catalog excerpts

Duct Fans-1

DUCT FANS TUBEAXIAL FANS • Capacities to 86,000 CFM • Static pressures to 3”WG VANEAXIAL FANS • Capacities to 100,000 CFM • Static pressures to 5”WG • Capacities to 60,000 CFM • Static pressures to 2”WG • Temperatures to 350°F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-5530 Visit us on the Web: http://www.nyb.com Phone: (800) 208-7918 Email: [email protected] TUBULAR ACOUSTAFOIL® • Capacities to 140,000 CFM • St

 Open the catalog to page 1
Duct Fans-2

DUCT FANS Duct Fans are designed and constructed for low pressure ventilating and industrial exhaust applications requiring the compactness of an axial fan. DESIGN FEATURES CONSTRUCTION FEATURES • Capacities – to 60,000 CFM. • Pressures – to 2”WG. • Thirteen sizes – 12” through 60” wheel diameters. of arrangements – or • Choicemounting positionsdirect-drive6]. belt-drive in five [see page • Steel wheel – curved blades assure efficient operation. Precision rolled tube – for minimum tip clearance...maximum efficiency. Arrangement 9-D with optional easy-access construction, motor, drive, and belt...

 Open the catalog to page 2
Duct Fans-3

APPLICATION ADVANTAGES New York Blower’s Duct Fans are designed for lowpressure ventilation and industrial-process applications. Uses include heat, smoke, and fume removal; process drying with ambient or preheated air; comfort and process cooling and general ventilation. All applications can be handled in either supply or exhaust configurations. Numerous modifications and accessories make the Duct Fan suitable for a wide range of systems. In applications where equipment space is at a premium, the compact flow-through design of the Duct Fan can reduce system space requirements by more than 50%...

 Open the catalog to page 3
Duct Fans-4

ACCESSORIES AND MODIFICATIONS 1. INLET BELL WITH GUARD – see page 5 Inlet bell minimizes losses associated with non-ducted inlet applications. Includes wire guard. 2. VIBRATION ISOLATION – see page 6 Rubber-in-shear or spring-type isolation mounts reduce the transmission of vibration to the mounting structure. 3. SAFETY EQUIPMENT/WEATHER COVER Belt guards, inlet and outlet guards, and weather covers are available. Selection of appropriate safety accessories is the responsibility of the system designer familiar with the specific installation. 4. COMPANION FLANGES – not shown Fit flush with fan...

 Open the catalog to page 4
Duct Fans-5

INLET BELL Catalog ratings shown in this bulletin are for Duct Fans with free inlet and ducted outlet. When no inlet duct is used, entrance loss must be added to the static pressure calculated for the system. For bare inlets, that loss is equal to the fan velocity pressure. Example: 4200 FPM velocity = 1.1 "WG [see Chart I at right]. Inlet bells render such loss negligible and are available at nominal cost. Sizes 127 through 487 constructed of fiberglass reinforced plastic; Sizes 547 and 607 constructed of steel. Available for all sizes of Duct Fans with matching standard flanges for either inlet...

 Open the catalog to page 5
Duct Fans-6

MOUNTING ARRANGEMENTS Arrangement 9-D with optional easy-access construction, motor, drive, and belt guard. Arrangement 4-S with optional spring isolation. 9-M Mounting Positions viewed from discharge end WITH MOUNTING LEGS Fabricated mounting legs facilitate fan mounting on the floor, ceiling, or in a vertical position on a wall. Flange connections are standard. Fans are equipped with four mounting brackets suitable for floor, platform, or ceiling mounting. Motor is located on centerline between two of the four brackets on Arrangement 9. Flange connections are standard. Mounting Positions Fans...

 Open the catalog to page 6
Duct Fans-8

DIRECT-DRIVE DUCT FANS Available in Sizes 127 through 547, the direct-drive Duct Fan is ideally suited for relatively clean-air applications at temperatures to 105°F. Elimination of external motor mounting structure permits installation in extremely tight locations and reduction in overall unit weight. The Arrangement 4 configuration virtually eliminates all regularly scheduled maintenance. External inlet vane dampers and variable frequency motor controllers are available to modulate airflow in process or commercial air-conditioning systems. Contact your New York Blower sales representative for...

 Open the catalog to page 8
Duct Fans-9

Belt-Drive Duct Fans Belt-drive Duct Fans are available in Sizes 127 through 607 for more aggressive airstreams or applications where temperatures may reach 350°F. Belt-drive arrangements include a shaft, bearings, and belt-well assembly that isolates bearings and drive components from airborne moisture and contaminants. In the event that system pressures or flow requirements change, belt-drive Duct Fans offer inherent performance flexibility. New performance is easily achieved by modifying readily accessible drives.

 Open the catalog to page 9
Duct Fans-10

Size 187 Belt-drive Wheel diameter: 18" Inlet and outlet area: 1.82 sq. ft. CFM Performance certified is for installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). PAGE 10

 Open the catalog to page 10
Duct Fans-12

Size 427 Belt-drive Wheel diameter: 42" Inlet and outlet area: 9.97 sq. ft. CFM Performance certified is for installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). PAGE 12

 Open the catalog to page 12
Duct Fans-13

Performance certified is for installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Electronic Catalog A complete New York Blower Catalog on one CD. No more manual calculations and bulky product catalogs. A critical tool for all system-designers and engineers who select and specify air-moving equipment. SELECTION BENEFITS • Fast, accurate fan selection. • Automatic altitude, temperature, and density corrections. • Sound levels by octave band. • Fan-performance curves. •...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.