Product catalog summary
Construction Features:
  • Efficient and quiet operation with cast aluminum wheels featuring airfoil-shaped blades.
  • Structural strength and durability ensured by heavy-gauge welded components.
  • Protection provided by industrial-grade nyb green coating.
  • Straightening vanes enhance efficiency by converting velocity pressure to static pressure.
  • Easy installation with flanged connections and slotted holes.
  • Maintenance ease with extended motor lubrication lines and external fittings.
  • Smooth operation due to precision-balanced wheels.
  • Easy wheel removal facilitated by tapered hub with split taper bushing.
Design Features:
  • Capacities up to 100,000 CFM and pressures up to 8” WG.
  • Thirteen direct-drive sizes available with multiple hub ratios.
  • Five mounting positions for direct-drive configurations.
  • Minimal tip clearance and maximum efficiency with precision rolled tube.
  • Blade pitch selected at the time of order.
Mounting Arrangements:
  • Arrangement 4-M: Floor, ceiling, or vertical wall mounting with legs.
  • Arrangement 4-V: Vertical mounting with standard flange connections.
  • Arrangement 4-S: Suspended mounting with side supports.
  • Arrangement 4-D: Duct mounting with inlet and discharge flanges.
  • Arrangement 4-R: Roof mounting with curb caps and optional stack hoods.
Accessories and Modifications:
  • Outdoor exhaust stack hood with back-draft dampers.
  • Vertical mounting curb cap with nailer holes and flange.
  • Gasketed access door for wheel inspection.
  • Various factory-mounted motors available.
  • Vortex damper assembly for volume control.
  • Drains for horizontally mounted fans.
  • Inlet bell with guard to minimize losses in non-ducted applications.
  • Vibration isolation mounts to reduce vibration transmission.
  • Safety equipment such as inlet and outlet guards.
  • Companion flanges and motor conduit box for increased efficiency.
Performance and Safety:
  • Safe operation depends on proper installation and maintenance.
  • System designer responsible for selecting safety accessories.
  • Performance certified for installation Type B: Free inlet, Ducted outlet.
Procedures for Fan Selection:
  • Use capacity tables to determine outlet velocity, RPM, and BHP based on fan size, CFM, and static pressure.
  • Correct static pressure for altitude and temperature using provided charts.
  • Example provided for selecting a fan for specific conditions.
Charts and Tables:
  • Chart I: Velocity pressure data for various FPM values.
  • Chart II & III: Maximum safe speeds and temperature correction factors.
  • Chart IV: Correction factors for temperature and altitude.
Fan Access Section: Detailed dimensions for fan access, including inlet vane damper and inlet bell dimensions, with specifications for flange gauges, fan I.D., and flange O.D., along with bolting circle details.
Material Specifications: Dimensions in inches, weights in pounds, and WR² in lb.-ft.² with tolerances of ±1⁄8”.
Motor Size Capability: Maximum frame sizes listed for different fan sizes, indicating motor size compatibility with specific fan dimensions.
Arrangement Dimensions: Detailed dimensions for arrangements 4-M, 4-S, and 4-D, including flange slots and mounting hole diameters, as well as dimensions for arrangement 4-R (roof-mounted) and 4-V.
General Information: The New York Blower Company emphasizes continual product improvement and reserves the right to change designs and specifications without notice. Dimensions should not be used for construction unless certified.
Product Offerings: The company offers a wide range of air-moving equipment, including dust/material handling fans, roof ventilators, process/fan components, heating products, air-handling (centrifugal and axial) systems, fiberglass reinforced plastic (FRP) fans, and custom products designed for unique applications.
See more

Catalog excerpts

Direct Drive Vaneaxial Fixed Pitch Fans-1

DIRECT DRIVE VANEAXIAL FIXED PITCH FANS • Capacities to 100,000 CFM • Static pressures to 8”WG • Temperatures to 105°F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-5530 Visit us on the Web: http://www.nyb.com Phone: (800) 208-7918 Email: [email protected]

 Open the catalog to page 1
Direct Drive Vaneaxial Fixed Pitch Fans-2

DIRECT DRIVE VANEAXIAL FANS Direct Drive Vaneaxial Fixed Pitch Fans are designed and constructed for high pressure ventilating and industrial process applications requiring the compactness of an axial fan. aluminum wheel – airfoil shaped blades pro• Cast highly efficient, quiet operation for clean-air vide • Capacities – to 100,000 CFM. • Pressures – to 8” WG. • Thirteen direct-drive sizes – 16” through 60” wheel diameters. DESIGN FEATURES CONSTRUCTION FEATURES Multiple • selection hub ratios are available – for increased flexibility. of configurations • Choice five direct-drivepositions. drive...

 Open the catalog to page 2
Direct Drive Vaneaxial Fixed Pitch Fans-3

Mounting ArrangementsARRANGEMENT 4-M WITH MOUNTING LEGS Fabricated mounting legs facilitate fan mounting on the floor, ceiling, or in a vertical position on a wall. Flange connections are standard. Fans are equipped with four mounting brackets suitable for floor, platform, or ceiling mounting. Flange connections are standard. Fans for suspended mounting are equipped with side supports suitable for attachment to rods hung from the ceiling structure. Flange connections are standard. Units feature flanges on inlet and discharge for mounting to the duct work. Roof-mounted fans are furnished with...

 Open the catalog to page 3
Direct Drive Vaneaxial Fixed Pitch Fans-4

ACCESSORIES AND MODIFICATIONS 1. STACK HOOD Stack hood with built-in back-draft dampers for vertical outdoor exhaust applications. Arrangement 4-R with curb cap, access door, stack hood, and motor. Gussetted cover with nailer holes on perimeter includes flange for vertical fan mounting. 3. ACCESS DOOR Gasketed, latch-type door swings open on hinges after turning cam levers...bolt-on door also available... provides visual access to wheel...available in all sizes. 4. MOTORS A wide-array of motors are available factory-mounted by nyb. 5. DAMPERS Bolt-on vortex damper assembly provides volume control...for...

 Open the catalog to page 4
Direct Drive Vaneaxial Fixed Pitch Fans-5

INLET BELL Catalog ratings shown in this bulletin are for Vaneaxial Fixed Pitch Fans with free inlet and ducted outlet. When no inlet duct is used, entrance loss must be added to the static pressure calculated for the system. For bare inlets, that loss is equal to the fan velocity pressure. Example: 4200 FPM velocity = 1.1 "WG [see Chart I at right]. Inlet bells render such loss negligible and are available at nominal cost. Sizes 12 through 48 constructed of fiberglass reinforced plastic; Sizes 54 and 60 constructed of steel. Available for all sizes of Direct Drive Vaneaxial Fixed Pitch Fans...

 Open the catalog to page 5
Direct Drive Vaneaxial Fixed Pitch Fans-7

Direct Drive Vaneaxial Fixed Pitch Fans Direct Drive Vaneaxial Fixed Pitch Fans are available in sizes 16 through 60. In the event that system pressures or flow requirements change, Direct Drive Vaneaxial Fan performance can be altered by changing to a new wheel with a different blade pitch.

 Open the catalog to page 7
Direct Drive Vaneaxial Fixed Pitch Fans-12

Material Specifications Dimensions in inches. Weights in pounds. WR2 in lb.-ft.2. Tolerance: ±Vfe"

 Open the catalog to page 12
Direct Drive Vaneaxial Fixed Pitch Fans-13

Maximum frame sizes are listed per size. *Slots spaced equally, straddling centerline. INLET BELL DIMENSIONS Size INLET VANE DAMPER DIMENSIONS Size

 Open the catalog to page 13
Direct Drive Vaneaxial Fixed Pitch Fans-14

DimensionsARRANGEMENTS 4-M, 4-S, AND 4-D DIMENSIONS [inches] Size The New York Blower Company has a policy of continual product improvement and reserves the right to change designs and specifications without notice. PAGE 14

 Open the catalog to page 14
Direct Drive Vaneaxial Fixed Pitch Fans-15

Dimensions Dimensions should not be used for construction unless certified. See page 3 for available mounting positions. Note motor size capability on page 13. Tolerance: ±V8" [roof-mounted] with optional exhaust-type stack hood. The New York Blower Company has a policy of continual product improvement and reserves the right to change designs and specifications without notice.

 Open the catalog to page 15
Direct Drive Vaneaxial Fixed Pitch Fans-16

COMPLETE SELECTION OF AIR-MOVING EQUIPMENT The New York Blower Company offers thousands of different types, models, and sizes of air-moving equipment. Contact your nyb representative for assistance in identifying the best fan for your application. AIR-HANDLING [AXIAL] For the ideal handling of clean to moderately dirty airstreams. Commercial and industrial HVAC, drying and cooling systems, fume extraction, and process-heat removal are typical applications. DUST/MATERIAL HANDLING Wide range of duty available with unique fan lines capable of handling light dust to heavy material. Typical applications...

 Open the catalog to page 16

All NYB catalogs and technical brochures

  1. Silencers

    3  Pages

  2. Vaneaxial Fans

    20  Pages

  3. Tubeaxial Fans

    16  Pages

  4. Duct Fans

    16  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.