Catalog excerpts
CF STRIATED INSULATED METAL WALL PANEL Metl-Span's CF Striated insulated metal panel is an LOCK & GROOVE SYSTEM attractive alternative to typical flat wall panels. The exterior face is lightly profiled with narrow longitudinal striations, which create a subtle shadow effect but exhibit a virtually flat appearance from a short distance away. The Striated wall panel is an exceptional value, combining the aesthetics of a flat wall panel with the high insulation ratings of an insulated foam core. NON-DIRECTIONAL EMBOSSED 8'-0" to 32'-0" Horizontal 8'-0" to 40'-0" for 24", 30", 36" Vertical 8'-0" to 32'-0" for 42" Vertical UNEMBOSSED 8'-0" to 16'-0" Horizontal 8'-0" to 16'-0" Vertical EXTERIOR PROFILE • Longitudinal striations, nominal 1/32" deep, embossed or unembossed EXTERIOR FACE • G-90 galvanized or AZ-50 aluminum-zinc coated steel in 24 and 22 Ga. INTERIOR PROFILE • Light Mesa, nominal 1/16" deep, embossed or INTERIOR FACE • G-90 galvanized or AZ-50 aluminum-zinc coated steel in 26, 24 and 22 Ga. JOINT • Offset double tongue-and-groove with extended metal shelf for positive face fastening REVEAL • Up to 1" reveal in 1/4" increments U-FACTOR (BTU/h·ft²·°F)** R-VALUE (h·ft²·°F/BTU)** *Available only from Nevada plant **Based on ASTM C518, ASTM C1363 and thermal modeling D E S I G N F E AT U R E S & B E N E F I T S • Minor striations provide up-close interest, with a flat appearance at a distance • Utilizes concealed clips and eliminates thermal short circuits © 2022 NUCOR BUILDINGS GROUP 03/22 • Easy and fast installation, with reduced construction labor costs • Interior and exterior applications • Can be used in conjunction with other Metl-Span joi
Open the catalog to page 1TESTING: CF STRIATED INSULATED METAL WALL PANEL T E ST/ A P P ROVA L TEST METHOD TEST TITLE Surface Burning Characteristics of Building Materials Flame spread <25, smoke developed <450 Fire Tests of Building Construction Materials One hour non-load bearing rating with two layers of Type X Gypsum Vertical or horizontal installation Fire Canada Thermal Performance Air Infiltration Water Infiltration Class 1 Fire Rating of Insulated Wall, Ceiling and Roof Panels Product approved Test Method for Potential Heat of Building Materials Potential heat of foam plastic insulation contained in the...
Open the catalog to page 2All Nucor Building Systems catalogs and technical brochures
-
ThermalSafe®
2 Pages
-
CF FLUTE
2 Pages
-
ORDER STEEL PRODUCTS
8 Pages
-
CREDENTIALS & RATINGS
16 Pages
-
WARRANTY PROGRAM
6 Pages
-
INSULATED METAL PANELS
16 Pages
-
Endwall Framing
6 Pages
-
Primary Framing
10 Pages
-
Specification Guide
32 Pages
-
Standard Product Summary
5 Pages
-
INTRODUCTION
2 Pages