CF SANTA FE INSULATED METAL WALL PANEL Metl-Span's CF Santa Fe panel has a flat exterior LOCK & GROOVE SYSTEM profile with a heavy, embossed stucco texture that mimics the look of a masonry stucco finish but with the added value of an insulated metal panel. The profile is flush with the warmness of an old-world finish, providing a visually pleasing building. PA N E L P R O F I L E C O R E • Foamed-in-place, zero ozone depleting (zero ODP) Class 1 foam J O I N T • Offset double tongue-and-groove with extended metal shelf E X T E R I O R P R O F I L E • Flat profile with heavy embossing resembling desert southwestern appearance E X T E R I O R F A C E • G-90 galvanized or AZ-50 aluminum-zinc coated steel in 24 and 22 Ga. I N T E R I O R P R O F I L E • Light Mesa, nominal 1/16" deep, embossed or unembossed I N T E R I O R F A C E • G-90 galvanized or AZ-50 aluminum-zinc coated in 26, 24 and 22 Ga. for positive face fastening R E V E A L • Up to 1" reveal options in 1/4", ½", 3/4" and 1" increments U - F A C T O R S A N D R - V A L U E S ** U-FACTOR (BTU/h·ft²·°F) R-VALUE (h·ft²·°F/BTU) *Available only from Nevada plant **Based on ASTM C518, ASTM C1363 and thermal modeling D E S I G N F E AT U R E S & B E N E F I T S • Masonry stucco appearance • Interior and exterior applications • Utilizes concealed clips and eliminates thermal short circuits • Can be used in conjunction with other Metl-Span joint profiles • Easy and fast installation, with reduced construction labor costs
Open the catalog to page 1TESTING: CF SANTA FE INSULATED METAL WALL PANEL T E ST/ A P P ROVA L TEST METHOD TEST TITLE Surface Burning Characteristics of Building Materials Flame spread <25, smoke developed <450 Fire Tests of Building Construction Materials One hour non-load-bearing rating with two layers of Type X Gypsum Vertical or horizontal installation Fire Canada Thermal Performance Air Infiltration Water Infiltration Class 1 Fire Rating of Insulated Wall, Ceiling and Roof Panels Product approved Test Method for Potential Heat of Building Materials Potential heat of foam plastic insulation contained in the...
Open the catalog to page 2All Nucor Building Systems catalogs and technical brochures
-
ThermalSafe®
2 Pages
-
CF FLUTE
2 Pages
-
ORDER STEEL PRODUCTS
8 Pages
-
CREDENTIALS & RATINGS
16 Pages
-
WARRANTY PROGRAM
6 Pages
-
INSULATED METAL PANELS
16 Pages
-
Endwall Framing
6 Pages
-
Primary Framing
10 Pages
-
Specification Guide
32 Pages
-
Standard Product Summary
5 Pages
-
INTRODUCTION
2 Pages