CF MESA INSULATED METAL WALL PANEL Metl-Span's CF Mesa insulated metal panel is well LOCK & GROOVE SYSTEM suited for exterior and interior walls and ceiling applications. The lightly corrugated profile on both faces creates symmetry on the outside of the building and room to room within. The minor rib provides a flattened appearance. Mesa panels are ideal for commercial, institutional and industrial applications. J O I N T • Offset double tongue-and-groove with extended metal shelf for positive face fastening NON-DIRECTIONAL EMBOSSED 8'-0" to 32'-0" Horizontal 8'-0" to 52'-0" Vertical UNEMBOSSED 8'-0" to 16'-0" Horizontal 8'-0" to 40'-0" Vertical E X T E R I O R P R O F I L E • Longitudinal planks spaced at nominal 4" on center, nominal 1/8" deep, embossed or unembossed E X T E R I O R F A C E • G-90 galvanized or AZ-50 aluminum-zinc coated steel in 26, 24 and 22 Ga. I N T E R I O R P R O F I L E • Mesa, nominal 1/8" deep or Light Mesa, nominal 1/16" deep, embossed or unembossed I N T E R I O R F A C E • G-90 galvanized or AZ-50 aluminum-zinc coated steel or 304 or 316 stainless steel in 26, 24 and 22~ Ga. C O R E • Foamed-in-place, zero ozone depleting (zero ODP) Class 1 foam U - FA C TO R S A N D R -VA L U E S * U-FACTOR (BTU/h·ft²·°F) R-VALUE (h·ft²·°F/BTU) ** Based on ASTM C518, ASTM C1363 and thermal modeling ~ 22 Ga not available for stainless steel D E S I G N F E AT U R E S & B E N E F I T S • Consistent high quality with foamed-in-place panel manufacturing • Easy and fast installation, with reduced construction labor costs • Easily washable • Interior and exterior applications • Utilizes concealed clips and eliminates thermal short circuits

Open the catalog to page 1
CF MESA INSULATED METAL WALL PANEL - 2

TESTING: CF MESA INSULATED METAL WALL PANEL T E ST/ A P P ROVA L TEST METHOD TEST TITLE Surface Burning Characteristics of Building Materials Flame spread <25, smoke developed <450 Fire Tests of Building Construction Materials One hour non-load bearing rating with two layers of Type X Gypsum Vertical or horizontal installation Fire Canada Thermal Performance Air Infiltration Water Infiltration Class 1 Fire Rating of Insulated Wall, Ceiling and Roof Panels Product approved Test Method for Potential Heat of Building Materials Potential heat of foam plastic insulation contained in the assembly...

Open the catalog to page 2

All Nucor Building Systems catalogs and technical brochures

  1. CF FLUTE

    2 Pages

  2. INTRODUCTION

    2 Pages