1. Catalogs
  2. NSK Europe Ltd.
  3. Technical specification & Safety
video corpo

Technical specification & Safety

Technical specification & Safety

Technical specification & Safety

Product catalog summary
Pulley Alignment
The LAB-Set uses two laser transmitters to project laser lines onto the opposite unit. Alignment is achieved by adjusting the pulleys so that the laser line coincides with the reference line on the opposite unit.
Mounting Instructions
Each unit is mounted on the pulley using strong magnets. Ensure fingers are not pinched. Position both units with spring action probes in the same groove on both pulleys, facing each other. Verify correct probe settlement by moving the units slightly along the groove.
Alignment Process
Turn on the lasers after mounting. Correct alignment is indicated when laser lines coincide with reference marks on both units. Begin by correcting angular errors if misalignment is detected. Ensure pulleys are correctly mounted and shafts are straight to avoid alignment issues.
V-guide Selector
The document provides a table for selecting the appropriate V-guide based on pulley groove width, belt profile, and pulley diameter.
Technical Specifications & Safety
The LAB-Set uses Class 2 laser diodes with power output <1mW. Safety precautions include avoiding direct eye exposure to the laser. The system complies with IEC-60825-1:2007 and other international standards. Key specifications include housing material (aluminium), weight (300g/unit), dimensions (61 x 77 x 61mm), and measurement accuracy (better than 0.5mm or 0.2 degrees).
Contact Information
Contact details for NSK sales offices across Europe, the Middle East, and Africa are provided for further assistance.
See more

Catalog excerpts

Technical specification & Safety-1

MOTION & CONTROL™ USER MANUAL LASER ALIGNMENT TOOL - BELT

 Open the catalog to page 1
Technical specification & Safety-2

Alignment process Pulley alignment The LAB-Set uses two laser transmitters for projecting of laser lines on the opposite laser unit. By adjusting the pulleys so that the laserline coincides with the reference line on the opposite laser unit, the pulleys are aligned. Mounting of the LAB-Set units Each unit is mounted on the pulley as shown in the graphic. NOTE! The magnet, which hold the unit to the pulley, are very strong. Do not pinch your fingers! Position both units with the spring action probes resting in the same grove on both pulleys and the units are facing each other as shown. Ensure that...

 Open the catalog to page 2
Technical specification & Safety-3

AVOID EXPOSURE - Laser radiation is emitted from this aperture AVOID EXPOSURE - Laser radiation is emitted from this aperture AVOID EXPOSURE - Laser radiation is emitted from this aperture AVOID EXPOSURE - Laser radiation is emitted from this aperture AVOID EXPOSURE - Laser radiation is emitted from Laser radiation AVOID EXPOSURE - this aperture is emitted from this aperture AVOID EXPOSURE - Laser radiation is emitted from Laser radiation AVOID EXPOSURE - this aperture is emitted from this aperture AVOID EXPOSURE - Laser radiation is emitted from this aperture AVOID EXPOSURE - Laser radiation...

 Open the catalog to page 3
Technical specification & Safety-4

V-guide selector Pulley groove width (mm) Belt profile Pulley datum diameter

 Open the catalog to page 4
Technical specification & Safety-5

Technical specication & Safety Technical specication Measuring units Housing material Weight Dimensions Battery type Operating time Measurement distance Measurement accuracy Pulley diameter range Pulley belt groove width Laser class Output power Laser wavelength Aluminium 300g /unit 61 x 77 x 61mm (H x W x D) 2 x LR03 (AAA) 1.5V per unit 50 – 6000mm 50 – 6000mm Better than 0.5mm or 0.2 degrees From 75mm and larger (standard) 6 – 40mm (standard) 2 <1mW 600 – 650nm Safety The LAB-Set uses laser diodes with a power output of less than 1.0mW. The laser classi­ fca­ ion is Class 2, which is considered...

 Open the catalog to page 5
Technical specification & Safety-6

NSK Sales Offices – Europe, Middle East and Africa UK NSK UK Ltd. Northern Road, Newark Nottinghamshire NG24 2JF Tel. +44 (0) 1636 605123 Fax +44 (0) 1636 643276 [email protected] France & Benelux NSK France S.A.S. Quartier de l’Europe 2, rue Georges Guynemer 78283 Guyancourt Cedex Tel. +33 (0) 1 30573939 Fax +33 (0) 1 30570001 [email protected] Middle East NSK Bearings Gulf Trading Co. JAFZA View 19, Floor 24 Office 2/3 Jebel Ali Downtown, PO Box 262163 Dubai, UAE Tel. +971 (0) 4 804 8205 Fax +971 (0) 4 884 7227 [email protected] South Africa NSK South Africa (Pty) Ltd. 25 Galaxy Avenue Linbro Business...

 Open the catalog to page 6