PCS-9726 Generation Management Unit

PCS-9726 Generation Management Unit

PCS-9726 Generation Management Unit

Product catalog summary
Overview: The PCS-9726 Generation Management Unit is a microprocessor-based device designed for the protection, measurement, and control of two-winding box-type transformers in new energy power stations, such as wind and photovoltaic power stations. It includes protocol conversion, ring-network communication, and supports an external color touch screen LCD for local monitoring.
Protection Functions:
  • Six stages of mechanical protection.
  • Three stages of phase overcurrent protection.
  • Two stages of negative sequence overcurrent protection.
  • Two stages of residual overcurrent protection.
  • One stage each of undervoltage and overvoltage protection.
  • Optional differential protection.
Measurement Functions:
  • 42 binary inputs and 26 analog inputs.
  • 3 groups of remote control signals.
  • 4 groups of 4-20mA signals and RTD signals.
Communication Functions:
  • Four Ethernet ports and Modbus support.
  • "Hand in hand" ring network via two pairs of optical interfaces.
Additional Functions:
  • Hardware and secondary circuit detection.
  • Clock synchronization with PPS and IRIG-B.
  • 64 disturbance records with waveforms.
  • User-friendly HMI interface and auxiliary debugging software.
  • Powerful waveform analysis tool.
Features:
  • High reliability through dual A/D sampling and mutual-check technology.
  • High performance with 64 disturbance records, 1024 supervision events, and 1024 binary events.
  • Powerful communication capabilities with 4 optical ports and 10 serial ports, supporting CAN bus and power industry communication standards.
See more

Catalog excerpts

PCS-9726 Generation Management Unit-1

PCS-9726 Generation Management Unit PCS-9726 generation management unit is a microprocessor-based device used for protecting, measuring and controlling two-winding box-type transformer in new energy power station (wind power station or photovoltaic power station etc.). It also includes the functions of protocol conversion and ring-network communication, and supports externally expanded color touch screen LCD to achieve local Protection Functions • Six stages of mechanical protection Three stages of phase overcurrent protection Two stages of negative sequence overcurrent protection Generation Management Unit side 2 Figure 1 Typical PCS-9726 Functional Block Diagram

 Open the catalog to page 1
PCS-9726 Generation Management Unit-2

GREEN(Renewable Energy Generation,Storage & Microgrid) • Two stages of residual overcurrent protection • One stage of undervoltage protection • One stage of overvoltage protection • Differential protection (optional) Measurement Functions • 42 binary inputs • 26 analog inputs • 3 groups of remote control signals • 4 groups of 4-20mA signals • 4 groups of RTD signals Communication Functions • Four Ethernet ports • Ten RS485/RS232 serial ports • Support of various protocols: IEC61850, IEC60870-5-103, Modbus. • “Hand in hand” ring network by two pairs of optical interface Additional Functions •...

 Open the catalog to page 2

All NR Electric catalogs and technical brochures

  1. PCS S Series

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.