qb701 - Laser Shaft Alignment System

Product catalog summary
General Overview
The KOHTECT qb701 is a laser shaft alignment system designed to ensure concentric machine axes under normal conditions by measuring and correcting misalignment in coupled machines.
Safety Precautions
Prevent unintentional machine starts during measurement and adhere to Class II laser safety guidelines to avoid direct eye exposure.
EC Declaration of Conformity
The qb701 complies with EMC Directive 2004/108/EC and other relevant European safety and performance standards.
Technical Description
The system measures shaft misalignment in parallel (offset) and angular (gap) values, calculating necessary adjustments for correction.
Specifications and Features
  • Measurement accuracy: 1%+0.01
  • Laser type: Visible red 635-670 nm, <1 mW
  • Operating temperature: -10 to +55°C
  • Power supply: Rechargeable Li-Ion battery
  • Features: Horizontal and vertical alignment, editable tolerances, shimming simulator.
System Package
Includes a display unit, two transducer units, mounting brackets, charger, USB cable, and carrying case.
Mounting and Adjustment
Transducers should be mounted at the same angular position on shafts, with laser beams aligned to transducer windows.
Getting Started
Instructions for powering, resetting, and navigating the menu are provided, with auto-save functionality.
Device Setup
Configure settings such as date/time, auto-off delay, connection type, interface language, and display brightness.
Horizontal Machine Alignment
Mount transducers, run the alignment program, enter dimensions, and set parameters for accurate alignment.
Measurement Mode – Clock Type
Measure misalignment by turning shafts to 9, 12, and 3 o’clock positions, taking readings at each to calculate corrections.
Transducer’s Positions Conventions
Adhere to angular positions: 6 o’clock - 0°, 9 o’clock - 90°, 12 o’clock - 180°, 3 o’clock - 270°.
Parameters
Run the Horizontal program, choose New Task, edit dimensions, and toggle settings like Spacer shaft and data input type.
Tolerance Setup
Use predefined RPM/tolerance tables or enter user-defined values, saving changes as needed.
Taking Measurements
Clock Mode: Take readings at 9, 12, and 3 o’clock positions. Multipoint Mode: Collect readings at any position from 3 to 36. Auto Shooting Mode: Automatically record data at stable positions.
Readings Quality Assessment
Data quality is assessed by standard deviation, indicated by color-coded dots: Blue (impossible), Green (good), Yellow (acceptable), Red (poor).
Result Screen
Displays misalignment and required corrections with directions for adjustments shown by blue arrows.
Movable Machine Adjustment
For vertical adjustments, use 6 or 12 o’clock positions; for horizontal, use 9 or 3 o’clock positions.
Machines with Spacer Shaft
Activate the Spacer Shaft option and follow the Horizontal program procedure.
Lock Feet Pair
Swap movable machine if needed, enter missed dimensions, and lock feet pair as required.
Report File Saving
Save report files at any alignment stage to an internal SD card or USB drive.
Soft Foot
Run the Soft Foot program to eliminate conditions before alignment by loosening and tightening bolts.
Vertical Machine Alignment
Mount transducers, run the Vertical program, mark positions, enter dimensions, and set parameters for alignment.
Machine Correction @45
Place transducers at 45° positions to avoid turning shafts when switching correction planes.
Charging Batteries
Charge using a USB type AC charger or PC/laptop USB port, with automatic termination upon completion.
Firmware Upgrade
Ensure full battery charge and follow steps to upgrade firmware using a USB thumb drive or Windows Mobile Device Center.
Firmware Upgrade Procedure
1. Initiate upgrade by pressing the designated key.
2. Confirm start of upgrade.
3. Replace existing files by pressing specified key and confirming.
4. Choose 'NO' when prompted, then proceed.
5. Complete upgrade and turn off device.
Standard Tolerances of Shaft Misalignment
Outlines alignment tolerance standards for machinery with flexible coupling, categorized by speed (rpm) with offset and angular measurements.
Delivery Set
Includes control display unit, measuring transducer units, brackets, chains, supporting rods, AC charger, tape measure, carrying case, operating instructions, ConSpect Software, and USB cable.
See more

Catalog excerpts

qb701 - Laser Shaft Alignment System-1

KOHTECT qb701 LASER SHAFT ALIGNMENT SYSTEM USER’S MANUAL

 Open the catalog to page 1
qb701 - Laser Shaft Alignment System-4

SAFETY PRECAUTIONS Be sure the machines to be measured, cannot be started unintentionally as this can cause injuries. For this purpose, before the mounting of equipment, either block the power switch in the “Off” position or remove the safety fuses. These precautionary rules must be followed until the measuring system is dismantled from the measured machine. LASER SAFETY PRECAUTIONS The KOHTECT qb701 alignment system is the class II laser device at typical wavelength of 650nm, delivered output power of less than 1 mW and maximum radiant energy per pulse of 0.1 mJ. The Class II laser comply with...

 Open the catalog to page 4
qb701 - Laser Shaft Alignment System-5

EC DECLARATION OF CONFORMITY We, NPP KOHTECT, 167, Pogranichnaya str., 201, Nikolaev, Ukraine herewith declare that the following product: Shaft Alignment Tool qb701 has been designed and manufactured in accordance with: EMC DIRECTIVE 2004/108/EC as outlined in the harmonized norm for EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use – Part 1: General Requirements, EN 55011: 2009 +A1:2010, EN 61000-4-2: 2009, EN 61000-4-3: 2006 +A1:2008 +A2:2010, EN 61000-4-4: 2004 +A1:2010, EN 61000-4-5: 2006, EN 61000-4-6: 2009, EN 61000-4-11: 2004 EUROPEAN ROHS DIRECTIVE 2011/65/EU...

 Open the catalog to page 5
qb701 - Laser Shaft Alignment System-6

TECHNICAL DESCRIPTION DESIGNATION qb701 alignment system (further as System) is designed for measurement of shaft axis misalignment of coupled machines, and calculation of movable machine adjustment required to eliminate misalignment that exceeds permissible tolerances; The machine alignment means adjustment of the relative position of two coupled machines (e.g. motor and pump) so that the center line of the axis will be concentric when the machines are running under normal working conditions. S transducer installed on the shaft of Stationary machine M transducer installed on the shaft of the...

 Open the catalog to page 6
qb701 - Laser Shaft Alignment System-7

MISALIGNMENT PARAMETERS Misalignment of any rotating machine is expressed in parallel (Offset) and angular (Gap) of the shafts. Most frequently in practice, both of them are present simultaneously. Different kinds of misalignment of axes are shown in Fig. 2. Parallel misalignment of axes – Offset (displacement) Angular misalignment of axes – Gap Parallel and angular misalignment of axes – (Offset + Gap) Fig 2 The parallel (Offset) and angular (Gap) misalignment of axes is determined in two mutually perpendicular planes. For the purpose of elimination of the parallel and angular misalignment of...

 Open the catalog to page 7
qb701 - Laser Shaft Alignment System-8

Separation distance between measuring transducer units, up to 10 m Display control operating temperature range, -10..+55 degree C Laser type: Visible red 635-670 nm, <1 mW Detector type: CCD, length 30 mm Electronic inclinometer resolution, 0.1 degree Power supply: Rechargeable Li-Ion battery Gross weight, incl. carry case, Built-in application programs and options: o horizontal shaft alignment at any shaft position, from 60°, up to 360º, up to 36 readings can be measured; auto sweep mode can be used; o vertical (flange machine) shaft alignment; o editable misalignment tolerances; o setup options;...

 Open the catalog to page 8
qb701 - Laser Shaft Alignment System-9

SYSTEM PACKAGE The System includes (Fig. 1): 1- AVV-711 display unit 2- two measuring transducer units – S, M 3 3- universal chain brackets for mounting of measuring units S, M 4- measuring tape 5- 120…240 Volts AC charger 6- USB PC communication cable 7- Operating instructions manual and ConSpect freeware on the internal drive of display unit 8- Carrying case with form-inserted 8 SYSTEM OVERVIEW Power button Detector window Laser aperture Locking thumb nut Mini USB charger connector

 Open the catalog to page 9
qb701 - Laser Shaft Alignment System-10

MOUNTING TRANSDUCERS • Firmly tighten rods 1 into the shaft brackets 2. Put thumb nut 3 into the bracket 2, then hook the chain 5 on the stud 4. Firmly tighten the thumb nut 3. Shaft brackets with rods must be mounted at the same angular position. Mount transducers on the rods. Always try to mount transducers at minimal possible radial height. Make sure that transducers are not touching brackets or machine parts. S, M transducers to be installed at the same height with labels faced up S transducer installed on the stationary machine Datum lines for measuring of dimension input M transducer installed...

 Open the catalog to page 10
qb701 - Laser Shaft Alignment System-11

LASER BEAM ADJUSTMENT • Loosen thumb nut and horizontally adjust transducer so the middle of the laser line is at the transducer’s window. Slightly tighten thumb nut then vertically adjust laser line to the center of the transducer’s window. Firmly tighten the thumb nut. Adjust second transducer in the same way. Use an angular adjustment only. Do not change transducers installation height!

 Open the catalog to page 11
qb701 - Laser Shaft Alignment System-12

GETTING STARTED COMMON CONTROL KEYS CONSIDERATION To turn ON/OFF display unit and transducers – press and hold the power button ~2 sec. In case the system hangs and device did not respond to any keys - press and hold the power button for ~10 sec, the system will be reset. To close any currently active window, without saving, except main menu of the device, press button (it serves as escape key). button in most cases causes applying (saving) changes (invoke selection) and exit (from edit box; or from current window, except such windows as collect data, aligning, soft foot and so on where it is...

 Open the catalog to page 12
qb701 - Laser Shaft Alignment System-13

qb701 User’s Manual SETUP MENU ITEMS – to setup date and time – to set device auto off delay in seconds. When set to 0 – auto off is disabled. – to install license file which enables measurement functions. Press 9, browse to the license file, press Enter to open and install licenses. + Function enabled, valid until 01.01.2099 Serial number – to switch between wireless/cable transducers connection. For wireless connection – press 1 or 2 to enter number of transducers to be connected

 Open the catalog to page 13
qb701 - Laser Shaft Alignment System-14

qb701 User’s Manual – to choose user interface language keys to choose language, then press – to switch qb701 into USB mass storage device mode. By default device can be connected to the PC via Microsoft Windows Mobile Device Center. USB mass storage device mode can be used as alternative. – to adjust the display backlight brightness to choose default alignment biaxial mode. In biaxial mode both horizontal and vertical machine aligning with live data update could be made at a static transducers position (e.g. 3 h). For QB-TSM transducers the only available mode is 1-D

 Open the catalog to page 14