LASER LEVEL TRANSMITTER TL400-I DATASHEET – V3.0x C TL400-I is a non-intrusive level transmitter with no moving parts, using an infrared laser technology (~920 nm) that is completely safe to the human eye (LASER CLASS-1). Its measurement principle is based on ToF (Time of Flight), providing an accurate and reliable distance measurement, regardless of the color or transparency of the surface1 . It can be used to measure from grains and solids to transparent liquids such as water and diesel. It has a robust housing, withstanding pressures up to 8 bar, and excellent resistance to flammable materials such as diesel, gasoline, or alcohol. With a measurement capacity up to 4 meters and 1 Hz sampling, TL400-I is an excellent alternative to level sensors based on ultrasonic, capacitive, or floating technology since it does not need to be in contact with the surface to be measured. The transmitter has a dedicated filter for non-static tank applications based on machine learning algorithms that have been validated in real-life situations and have configurable parameters for specific applications. The sensor allows you to configurate the opening angle, ranging from 12° degrees for irregular tank or reservoir applications to 27° degrees for tanks where the base diameter is half the height to be measured. TL400-I has a BLE (Bluetooth Low Energy) interface. With it you can: • Configure the analog output (4-20 mA), according to the specific application. Configure the opening angle of the sensor (from 12° to 27° opening degrees). Customize the tank with up to 20 points in level percentage. Perform sensor diagnostics in real time. Configure the dynamic filter based on the application. • Update the firmware to the most current version, which will always be available on NOVUS website. These functions can be adjusted through the SigNow app, available for Android and iOS. The sensor can retransmit the analog output in Level, Volume, or Distance. Level and distance are set in your preferred unit (mm, cm, m, inches, or feet) and volume is always displayed in percent. The figure below shows TL400-I in an application: 1 In sunlit environments or in small to medium sized tanks that have reflective walls, the sensor may have difficulty to make an accurate measurement. See recommendations for use and application. NOVUS
Open the catalog to page 1
The figures below show the dimensions of the TL400-I and the gasket: The figure below shows the dimensions and drilling of the adapter for attaching the equipment: NOVUS AUTOMATION
Open the catalog to page 2
ELECTRICAL CONNECTIONS The output connector is a M12 type with the following wiring connections: M12 male output connection TL400-I has two accessory cables, which can be purchased separately: • 1 m PVC sensor cable 4-pin | M12 female connector (Order code: 8806065000) 3 m PVC sensor cable 4-pin | M12 female connector (Order code: 8806065100) The connection to the M12 female connector must be made in accordance with the following wiring connections: M12 female output connection ANALOG INPUT CONNECTION Below is an example of how to connect the output to an analog input: Analog input...
Open the catalog to page 3
TECHNICAL SPECIFICATIONS FEATURES Distance Measurement Minimum of 30 mm but can reach 2 mm if in good measuring conditions.2 Blind spot Standard SAE 5 holes or adapter for standard 4 holes. Power Supply Storage Temperature Operation Temperature Protection Index Configuration Application CE, Anatel (13883-22-07089), LASER CLASS 1, ISO 16750-2 Table 1 – Technical specifications CE MARK This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. LASER CLASS 1 The radiation used by the sensor...
Open the catalog to page 4All Novus Automation catalogs and technical brochures
-
Climate Air+
2 Pages
-
TxBlock-USB
2 Pages
-
Temperature Controller N1020
1 Pages
-
Electronic Thermostats
2 Pages
-
RHT-Air
2 Pages
-
NXperience Trust Flyer
2 Pages
-
Novus Cloud Flyer
1 Pages
-
LogBox Wi-Fi Flyer
2 Pages
-
LogBox LTE Flyer
2 Pages
-
DigiRail IoT Flyer
2 Pages
-
TL400
1 Pages
-
NP640
1 Pages
-
N1200
2 Pages
-
N1500
2 Pages
-
N1030
2 Pages
-
DigiRail OEE
2 Pages
-
Temperature Transmitters
2 Pages
-
FieldLogger
3 Pages
-
N1540
2 Pages
-
pressure transmitter np785
1 Pages
-
AirGate-4G
2 Pages
-
Modular Controller Flyer
2 Pages
-
NOVUS General Catalog
28 Pages
-
LogBox Wi-Fi
2 Pages
-
NP600
1 Pages
-
Egg Incubator
2 Pages
-
AirGate-Modbus NOVUS
2 Pages
-
NOVUS ISO 9001
2 Pages
-
Novus Reach Declaration
1 Pages
-
TxBlock & TxRail
2 Pages
-
NOVUS Cloud
2 Pages
-
PROCESS INDICATOR - N1040i
2 Pages
-
Flyer TxRail-USB
1 Pages
-
Flyer DigiGate Profibus
2 Pages
-
Flyer N323RHT
1 Pages
-
Flyer RHT Climate
2 Pages
-
Data Logger LogBox-RHT-LCD
2 Pages
-
N 480
1 Pages
-
NT 240
1 Pages
Archived catalogs
-
AirGate Catalog
2 Pages
-
DigiRail Signal Conditioner
2 Pages