LogBox LTE Flyer
1 / 2Pages

Catalog excerpts

LogBox LTE Flyer - 1

IoT Multi Channel Data Logger LogBox LTE • Suitable for mobile applications in long distance locations • Configuration and data download via USB or NOVUS Cloud • SMS alarm notification • Built-in rechargeable backup battery • Easy integration with NOVUS Cloud • Data communication via LTE network through NXperience and SCADA EASY COMISSIONING NXPERIENCE TRUST Alarm notification Up to 80 hours* of operation, in energy saving mode MQTT Protocol (Publisher and Subscriber) NOVUS Cloud integrated GMP and FDA Regulation Title 21 CFR Part 11 compliance LogBox LTE is an IoT data logger with NB-IoT, Cat.M1 or GPRS communication network. This device allows monitoring and data recording remotely, in installations with LTE infrastructure, perfectly suitable for mobile applications at long-distance locations or sites that do not need to use IT infrastructure. The device has two analog inputs, plus a digital input and one digital output. LogBox LTE works with MQTT protocol both in publisher and subscriber mode, therefore it can publish data to IoT brokers and also read commands, enabling to remotely execute some commands. Remote connection with low-cost infrastructure and application versatility are the highlights of this product. LogBox LTE has a built-in rechargeable backup battery to keep data safe during a power outage. SMS notification and easy integration with NOVUS Cloud will also help commissioning this device quickly. LogBox LTE uses NXperience software, wich has the NXperience Trust, a version that meets GMP (Good Manufacturing Practice) compliance, meeting with the technical requirements of FDA Regulation Title 21 CFR Part 11 for validation of computer systems.

Open the catalog to page 1
LogBox LTE Flyer - 2

Topology Vaccine Monitoring Level Measurement Technical Specifications Input Channels 2 analog 2 interns 1 digital Memory Capacity Record Interval 1 second to 12 hours (recommended: 300 seconds) Compatible Analog Signals Record Type Internal Measurements Internal Temperature (NTC) Battery Voltage External Power Supply Voltage Registry Trigger Date/time, alarm, start button, digital input, software command or SMS Input Impedance of Analog Channels 10 alarms available (can activate digital output, send SMS and MQTT publication) Maximum compensated cable resistance: 25 Ω Excitation current:...

Open the catalog to page 2

All Novus Automation catalogs and technical brochures

  1. Climate Air+

    2 Pages

  2. TxBlock-USB

    2 Pages

  3. RHT-Air

    2 Pages

  4. TL400

    1 Pages

  5. NP640

    1 Pages

  6. N1200

    2 Pages

  7. N1500

    2 Pages

  8. N1030

    2 Pages

  9. DigiRail OEE

    2 Pages

  10. FieldLogger

    3 Pages

  11. N1540

    2 Pages

  12. AirGate-4G

    2 Pages

  13. LogBox Wi-Fi

    2 Pages

  14. NP600

    1 Pages

  15. NOVUS Cloud

    2 Pages

  16. N 480

    1 Pages

  17. NT 240

    1 Pages

Archived catalogs