Introduction
DigiGate Profibus is a gateway device designed to interconnect a Profibus DP network with a Modbus RTU network. It functions as a master station in the Modbus network and a slave station in the Profibus network, facilitating data exchange between the two.

Principles of Operation
The device operates by reading data from Modbus network slaves and sending it to the Profibus master. It also writes data to Modbus slaves based on Profibus master requests. Configuration is done via DigiConfig software, which allows easy access and modification of parameters.

Profibus Specifications
  • Protocol: Profibus DP
  • Communication rates: 9600 bps to 12 Mbps
  • Addressing range: 0 to 125
  • Automatic baud rate detection
  • Includes GSD file and termination/polarization resistors
  • Connection: DB9 connector

Modbus Specifications
  • Communication rates: 1200 bps to 115200 bps
  • Includes termination/polarization resistors
  • Bus protection: ±60 Vdc, 15 kV ES
  • Data reading commands: Read Coil Status, Read Input Status, Read Holding Register, Read Input Register
  • Data writing commands: Force Single Coil, Preset Single Register, Force Multiple Coils, Preset Multiple Registers

General Specifications
  • Operating environment: 0 to 50 °C, 30 to 80% relative humidity
  • Mounting: DIN 35 mm rail
  • Electrical insulation: 1000 Vac between Profibus interface and device
  • Power supply: 10 to 35 Vdc with internal protection against inverse polarity
  • Frontal indicators for communication and status

Configuration Process
During configuration, the Modbus interface operates as a slave. A computer with USB-RS485 connects to the Modbus interface, and DigiConfig software acts as a Modbus network master. The CFG key initiates configuration mode, allowing parameter changes via the DigiConfig interface. After configuration, the device returns to normal operation.

Electrical Connections
Details on Profibus and Modbus connections are provided, including pin descriptions and terminal connections for power and RS485 communication.
See more

Catalog excerpts

Flyer DigiGate Profibus-1

DigiGate-Profibus Introduction DigiGate Profibus is the ideal equipment for interconnecting a Profibus DP network with a Modbus RTU network. It works as a gateway, operating as a master station in the Modbus network and as a slave station in the Profibus network. Thus, according to its previous configuration, DigiGate will read the data of the other devices (slaves) of the Modbus network and send the read values to the Profibus master. In the same way, it will write at the output of the Modbus slaves according to the Profibus master requests, providing a complete control of the Modbus network devices through the Profibus network. The device is totally configurable through the application DigiConfig for Windows®, which comes with the product, making access and change of its parameters really easy. Features  Commands available for data reading: “01 Read Coil Status”, “02 Read Input - Status”, “03 Read Holding Register” and “04 Read Input Register”  Protocol: Profibus DP  Operates at the entire range of communication rates, from 9600 bps to 12  Commands available for data writing: “05 Force Single Coil”, “06 Preset Mbps  Addressing range: 0 to 125  Automatic detection of supported baud rate  Termination and polarization resistors included (activated by jumper)  Profibus connection: DB9 connector Modbus  Operates from 1200 bps to 115200 bps  Termination and polarization resistors included (activated by jumper)  Protection at the bus: ±60 Vdc, 15 kV ES Single Register”, “15 Force Multiple Coils” and “16 Preset Multiple Registers” General Operating environment: 0 to 50 °C, 30 to 80% of relative humidity, without condensation Mounting: DIN 35 mm rail Electrical insulation between the Profibus interface and the rest of the device: 1000 Vac Power supply: 10 a 35 Vdc. Internal protection against inverse polarity Frontal lit indicators for communication and status Principles of Operation The data interchange in the DigiGate is performed through an internal memory table of the device, which is shared between the Profibus side and the Modbus side. This data interchange mode is very simple, since the Profibus control system will only need reading the data from this table, which is continuously fed and updated through the reading operation performed by the Modbus. In the same way, the Profibus will write the data in this table so that the Modbus can forward the new values to the correct registers of the corresponding slaves. Profibus Master

 Open the catalog to page 1
Flyer DigiGate Profibus-2

Electrical Connections The configuration of the DigiGate Profibus is entirely performed by the DigiConfig for Windows® software. During the configuration process, the Modbus interface of the DigiGate will stop working as a master and start operating as a slave. On this condition, a computer equipped with a USB-RS485 is connected to the Modbus interface, and DigiConfig software will work as a Modbus network master in order to perform the DigiGate configuration. For setting the DigiGate into configuration mode, press the CFG key and start the automatic search in the DigiConfig software. The DigiConfig configuration...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.