N 1020 - 1

The temperature controller N1020 features advanced performance capability for the most complex and critical applications. Based on a high-end microprocessor and designed with a sophisticated auto-adaptive PID algorithm it continuously adjusts the PID parameters for best controlling The programmable input, configurable dual output along with the full range power supply provide maximum flexibility This 1/32 DIN size instrument has extremely small front dimensions of only 48x24 mm or 1/32nd DIN and is the right choice for controlling laboratory equipment when panel ■ High brightness red LED display • Programmable input: thermocouples, Ptl 00 RTD and 50 mV • Dual output: 1 pulse and 1 relay • Output funtions: control, alarm 1, alarm 2 ■ Measured value offset • Minimum and maximum limitsfor SPsetting • Minimum and maximum limitsforoutput value ■ Access password for configuration protection • Factory calibration settings restoration feature • Silicone keypad ■ Front pannel: IP65, polycarbonate UL94V-2 . AMBIENT CONDITIONS: Thermocouples, Ptl 00 and voltage (according toTabel 01) Internal Resolution: 32767 levels (15 bits) Display Resolution: 12000 levels (from -1999 to 9999) Input sampling rate: up to 55 per second Accuracy: thermocouples J, K,T, E: 0.25 % of span ±1 °C Accuracy: thermocouples N, R, S, B: 0.25 % of span ±3 °C Input impedance: Ptl00 and thermocouples: > 10 MOhm Ptl00 measurement: 3-wires, (=0.00385) with cable length compensation, 0.170 mA excitation current . OUT1: voltage pulse; 5 V / 25 mA / (Zout= 47 Ohms) . CONNECTORS PROTECTION: IP30, ABS+PC UL94 V-0 • Programmable PWM cycle from 0.5 up to 100 seconds ■ Operation starts 3 seconds after power up ACCEPTED SENSORS AND MAXIMUM RANGES TIMER FUNCTION A built-in timer function is available for time down monitoring during control cycles. The timer start/stop options are: • When PV value reaches control SP value; . When starting control (RUN= YES); • Through the "F" key - reset mode: by pressing "F"the timer is automatically zeroed and a new cycle is started; . Through the "F" key - ON/OFF mode: by pressing "F" the timer halts; by pressing "F" again the timer resumes counting. Options for Time Down function: • At the end of the time cycle control output (RUN= NO) goes off; • At the end of the time cycle the alarm output goes off.

Open the catalog to page 1
N 1020 - 2

ELECTRICAL CONNECTIONS Sensor Break (input Error) Minimum Value Maximum Value Differential High ALARM FUNCTIONS Goes on with sensor failure/break Timer On Alarm. Sets the alarm to go on while timer is counting End of timer alarm. Sets the alarm to go on ilarm alarrr SPAn positive SPAn positive alarm alai SPAn negative SPAn negative positive SPAn negative SPAn Alarm Functions Alarm Event Timer Alarm Functions

Open the catalog to page 2

All Novus Automation Inc. catalogs and technical brochures

  1. NP640

    1 Pages

  2. TL400

    3 Pages

  3. N1200

    2 Pages

  4. N1500

    2 Pages

  5. N1030

    2 Pages

  6. DigiRail OEE

    2 Pages

  7. FieldLogger

    3 Pages

  8. N1540

    2 Pages

  9. AirGate-4G

    2 Pages

  10. LogBox Wi-Fi

    2 Pages

  11. NP600

    1 Pages

  12. NOVUS Cloud

    2 Pages

  13. TxBlock-USB

    1 Pages

  14. N 480

    1 Pages

  15. Novus N320

    1 Pages

  16. NT 240

    1 Pages

  17. RHT air

    2 Pages

Archived catalogs