Overview: The NOVOHALL Rotary Sensor Series RFC-4800 employs touchless hall technology, offering a full 360° range with high protection classes (IP67, IP69). It is suitable for industrial and mobile applications, meeting high EMC requirements and safety standards.
Special Features: The sensor has a two-part, mechanically decoupled design for wear-free operation, with a resolution up to 14 bits. It operates between -40°C and +105°C and supports interfaces such as Voltage, Current, SSI, Incremental, CANopen, SPI, and IO-Link.
Applications: Applicable in manufacturing engineering, automation technology, medical engineering, mobile machinery, and marine environments.
Mechanical Data: Constructed from high-grade, temperature-resistant plastic, the sensor supports continuous 360° mechanical travel and is vibration and shock resistant per IEC standards.
Electrical Data: Offers ratiometric output signals, supports single and multi-channel versions, and includes short circuit and reverse voltage protection with high insulation resistance.
Environmental Data: Operates from -40°C to +105°C, with a reduced range when using an M12 connector. It has a high mean time to failure (MTTF) and complies with various EMC standards.
Ordering Specifications: Provides detailed specifications for analog and digital versions, including supply voltage options, electrical connections, output characteristics, and mechanical versions.
Accessories: Includes position markers, M12 connector systems, and signal processing options.
Specifications: Details technical specifications for interfaces like SSI, Incremental, SPI, CANopen, and IO-Link, each with specific supply voltage requirements and operational parameters.
SSI Protocol: Describes connection assignments and operational details, with supply voltage options of 5 VDC and 24 VDC, and outputs compatible with RS-422 and TTL levels.
Incremental Interface: Provides electrical data for industrial and mobile applications, detailing supply voltage, output levels, and operational speed.
SPI Interface: Focuses on binary coding and TTL level signals, with a 14-bit resolution across 360° and a maximum clock rate of 400 kHz.
CANopen Interface: Details measured variables, output signals, and programmable parameters, specifying resolution, update rate, and environmental data.
IO-Link Interface: Outlines electrical data, including measured variables, resolution, and update rate, with a focus on functional safety and EMC compatibility.
Environmental and Safety Standards: Includes operating temperature ranges, MTTF, and EMC compatibility standards for each interface.
Ordering Specifications: Details ordering codes for different interfaces and mechanical versions, including preferred types and delivery times.
Position Markers Specifications: Details various position markers with specific fixation methods and radial offset limits.
Mounting Instructions: Recommends mounting on non-magnetizable materials to maintain working distances, noting reduced distances on magnetizable shafts.
Linearity Error and Working Distances: Provides data on additional linearity errors at various radial displacements and working distances.
Connector Systems: Details M12 connectors, including pin assignments, temperature ranges, and protection classes.
Multifunctional Measuring Device (MAP4000): Features supply voltage options, high accuracy, and optional interfaces like RS 232 and RS 485.
Connecting Options: Customizable connectors available in various pole versions and lengths, all with IP67 protection.
General Notes: Specifications are for informational purposes and may vary based on application conditions. Users should verify performance parameters in their specific applications. Product specifications are subject to change without notice.
See more

Catalog excerpts

Series RFC-4800-1

Siedle Group NOVOHALL Rotary Sensor touchless technology Series RFC-4800 Special features • Touchless hall technology • Electrical range up to 360° • 2-part, mechanically decoupled • High protection class, IP67, IP69 • Resolution up to 14 bit • Wear-free • Temperature range -40 °C to +105 °C • Single and multi-channel versions • Optimized for use in industrial and mobile applications with highest EMC requirements such as ISO pulses and high interferences to ISO 11452 and ECE-Standard • Suitable for safety-relevant applications according to DIN EN ISO 13849 • Interfaces: Voltage, current, SSI, incremental, CANopen, SPI, IO-Link • Customized versions The two-part design consisting of sensor and magnetic position marker offers great flexibility when mounting. The absence of shaft and bearing makes the assembly much less sensitive to axial and radial application tolerances - separate couplings are obsolete. Measurements can be made transmissively through any nonferromagnetic material. The sensor is perfectly suitable for use in harsh environmental conditions through the completely encapsulated electronics. Applications • Manufacturing Engineering Textile machinery Packaging machinery Sheet metal and wire machinery • Automation technology • Medical engineering • Mobile working machines Industrial trucks Construction machinery Agricultural and forestry machinery • Marine applications

 Open the catalog to page 1
Series RFC-4800-2

Analog Versions for Industrial Applications Technical Data 6 Analog Versions for Mobile Applications Technical Data 8 Incremental for Industrial an Mobile Applications 11 Fieldbus Versions, IO-Link CANopen 16 Accessories Position Markers 19 Customized Versions Connecting Options 27 Page 2 back to contents

 Open the catalog to page 2
Series RFC-4800-3

CAD data see www.novotechnik.de/en/ download/cad-data/ Pin assignment M12 connector

 Open the catalog to page 3
Series RFC-4800-4

Siedle Group Description Housing high grade, temperature resistant plastic Electrical connection Cable 4 x 0.5 mm2, AWG 20, TPE, shielded (analog voltage / current CE, CANopen) Cable 4 x 0.5 mm2, AWG 20, TPE, unshielded (analog voltage / current mobil) Cable 5 x 0.14 mm2, AWG 26, PUR, shielded (SPI) Cable 8 x 0.25 mm2, AWG 24, TPE, shielded (SSI, Incremental, CANopen IN/OUT) Wire 0.5 mm2, AWG 20, PVC (analog voltage / cuirent mobile, Incremental Open Collector) Connector M12x1, 4-pin / 5-pin / 8-pin with cable L=0.15 m Connector AMP-Superseal, 4-pin with cable L = 0.15 m Mechanical Data Dimensions...

 Open the catalog to page 4
Series RFC-4800-5

Output Characteristics Two channels, crossed output characteristics, channels 1 cw On request: Two channels, signal 2 = 0.5 x signal 1 On request: 2 offset output characteristics On request: Different gradients On request: Trapezoid output characteristic On request: Parabolic output characteristic

 Open the catalog to page 5
Series RFC-4800-6

Siedle Group Technical Data -Analog Versions for Industrial Applications Technical Data - Versions for Industrial Applications Design optimized for use in machine and plant engineering. High reliability, simple interface to PLC, high variety. Type Designations RFC-48_ _-- 2 _ _ -___ RFC-48__- _ ratiometric voltage Electrical Data Output signal ratiometric to supply voltage 0.1 ... 10 V Diagnosis activated (in case of error output signal is outside of the plausible signal range) Update rate typical 3.4 Resolution Measuring range Independent linearity Repeatability Hysteresis at measuring range...

 Open the catalog to page 6
Series RFC-4800-7

Ordering Specifications -Analog Versions - Voltage - Current for Industrial Applications Ordering specifications Preferred types printed in bold: • Delivery time up to 25 pcs. within 10 working days EXW • Best low-volume pricing Output signal supply voltage Ub = 24 V 1: 0.1...10 V (only one-channel) 2: 4 ... 20 mA (only one-channel) Output signal supply voltage Ub = 5 V 1: 0.25 ... 4.75 V ratiometric to supply voltage Ub (5 ... 95 %) 2: 0.5 ... 4.5 V ratiometric to supply voltage Ub (10 ... 90 %) Output characteristics 1: Rising cw 2: Rising ccw 3: Crossed output channel 1 rising cw (partly redundant)...

 Open the catalog to page 7
Series RFC-4800-8

Technical Data Analog Versions - Voltage - Current for Mobile Applications Technical Data - Versions for Mobile Applications These versions are optimzed for the high requirements in mobile applications. Tested to the highest requirements as ISO-pulses and high interferences to ISO 11452. Type Designations Output signal ratiometric to supply voltage Ub 0.25 ... 4.75 V (5 ... 95 %) 0.5 ... 4.5 V (10 ... 90 %) (load >5 kΩ) activated (in case of error output signal is outside of the plausible signal range) Update rate Measuring range Independent linearity Hysteresis at measuring range < 360° Hysteresis...

 Open the catalog to page 8
Series RFC-4800-9

Ordering Specifications -Analog Versions for Mobile Applications Ordering specifications Preferred types printed in bold: • Delivery time up to 25 pcs. within 10 working days EXW • Best low-volume pricing RFC - 4 8 5 1 Supply voltage 2: Supply voltage Ub = 5 V (4.5 ... 5.5 V) 3: Supply voltage Ub = 12/24 V (8 ... 34 V) Output signal Supply voltage Ub = 5 V 1: 0.25 ... 4.75 V ratiometric to supply voltage Ub (5 ... 95 %) 2: 0.5 ... 4.5 V ratiometric to supply voltage Ub (10 ... 90 %) Output signal supply voltage Ub = 12/24 V 2: 4 ... 20 mA 4: 0.5 ... 4.5 V 5: 0.25 ... 4.75 V Output characteristics...

 Open the catalog to page 9
Series RFC-4800-10

Type Designations RFC-48_ _-212-41 _-___ RFC-48 _ _-212-44 _- _ Supply voltage 5 VDC Supply voltage 24 VDC novotechnik Siedle Group Technical Data SSI Interface Electrical Data Protocol Inputs Monoflop time (tm) Coding Update rate (internal) Resolution across 360° Measuring range Maximum operational speed position marker Independent linearity Repeatability Hysteresis Temperature error Supply voltage Ub Current consumption (w/o load) Reverse voltage Short circuit protection Ohmic load at outputs Max. clock rate Insulation resistance (500 VDC) Cross-section cable Environmental Data Operating temperature...

 Open the catalog to page 10
Series RFC-4800-11

Type Designations Electrical Data Outputs Level Length Z-pulse Pulses per revolution Counts per revolution (after quadrature) Option Low Speed - Minimum edge separation - Minimum input frequency of counter input - Maximum operational speed Option High Speed - Minimum edge separation - Minimum input frequency of counter input - Maximum operational speed Measuring range Independent linearity Repeatability Hysteresis Temperature error Supply voltage Ub Current consumption (w/o load) Reverse voltage Short circuit protection Ohmic load at output Insulation resistance (500 VDC) Cross-section cable...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.