1. Catalogs
  2. Novatest
  3. NOVASCAN C310A - Technical Sheet

NOVASCAN C310A - Technical Sheet

NOVASCAN C310A - Technical Sheet

NOVASCAN C310A - Technical Sheet

Product catalog summary
Overview
The Novascan C310A is an electrochemical analysis system designed to measure corrosion potential and rate in steel reinforcement within concrete. Corrosion leads to a reduction in the steel bar's cross-sectional area and an increase in volume, causing concrete cracking and spalling, which compromises structural safety. Detecting corrosion levels is crucial for assessing the degradation state and safety of structures.

Applications
The system employs electrode polarisation theory and adheres to the electrochemical test method (half-cell potential method) as per ASTM C876, EN 13791, and UNI 10174 standards for structural integrity assessment.

Advantages
  • High detection precision with a corrosion voltage detection accuracy of +/- 0.1 mV.
  • Hierarchical results display showing the degree of corrosion in a chart format.
  • Two working modes: single electrode and double electrode for operational flexibility.

Technical Specifications
  • Range: +/- 1000 mV
  • Accuracy: 0.1 mV
  • Power supply: Internal rechargeable lithium battery
  • Storage capacity: 234 points
  • Electrode dimensions: ϕ30 mm × 180 mm
  • Survey area: 234 m2
  • Dimensions: 212 mm × 134 mm × 50 mm
  • Weight: 0.9 kg

Accessories
  • Main acquisition and display unit
  • Single electrode probe with clamp
  • Double electrode probe for simultaneous readings
  • Copper sulphate container for reference electrode solution
  • Complete set of field connection cables
  • Professional Windows software for data processing and reporting
  • Dedicated charger for the internal lithium battery
  • USB drive with complete instruction manual
  • Marking pencil for field annotations
  • Certificate of conformity
  • Hard carrying case for transport and storage

Contact Information
Novatest S.r.l. — Via Albertini 36/F8, c/o Center Gross, 60131 Ancona (AN) | T. +39 071.2415386 | [email protected] | www.novatest.it
Note: Product data is subject to change without notice.
See more

Catalog excerpts

NOVASCAN C310A - Technical Sheet-1

Engineering Solutions Electrochemical analysis system for measuring corrosion potential and rate Overview Corrosion of steel reinforcement inside concrete reduces the effective cross-sectional area of the steel bar and leads to an increase in volume. This expansion causes cracking and spalling of the concrete element, reducing its mechanical properties and durability, and consequently compromising the safety of the affected structures. The detection of the corrosion level of steel bars in concrete elements is therefore one of the fundamental parameters to consider in the identification of the degradation state and in the assessment of the safety of the structure under examination. NOVATEST S.r.l. Via Albertini, 36/F8 c/o Center Gross 60131 Ancona (AN) www.novatest.it RI^fP NDT Examination Center Approved by RINA

 Open the catalog to page 1
NOVASCAN C310A - Technical Sheet-2

Engineering Solutions The Novascan C310A electrochemical analysis system uses the electrode polarisation theory and is designed according to the electrochemical test method (half-cell potential method), as prescribed by regulations on structural integrity assessment (ASTM C876, EN 13791, UNI 10174). NOVATEST S.r.l. Via Albertini, 36/F8 c/o Center Gross 60131 Ancona (AN) www.novatest.it RI^fP NDT Examination Center Approved by RINA

 Open the catalog to page 2
NOVASCAN C310A - Technical Sheet-3

Engineering Solutions NOVATEST S.r.l. Via Albertini, 36/F8 c/o Center Gross 60131 Ancona (AN) www.novatest.it RI^fP NDT Examination Center Approved by RINA

 Open the catalog to page 3
NOVASCAN C310A - Technical Sheet-4

Via Albertini, 36/F8 c/o Center Gross 60131 Ancona (AN)

 Open the catalog to page 4
NOVASCAN C310A - Technical Sheet-5

B) Elaborazione dei dati relativi ai test del potenziale di corrosione Can) 0 10 20 30 40 50 60 70 SO 90 100 110 Novatest S.r.l. — Via Albertini 36/F8, c/o Center Gross, 60131 Ancona (AN) | T. +39 071.2415386 | [email protected] | www.novatest.itProduct sheet prepared by Novatest S.r.l. Data subject to change without notice.NOVATEST S.r.l. Via Albertini, 36/F8 c/o Center Gross 60131 Ancona (AN) www.novatest.it RI^fP NDT Examination Center Approved by RINA

 Open the catalog to page 5

All Novatest catalogs and technical brochures

  1. NOVATank

    3  Pages

  2. Qmini A10

    2  Pages

  3. Qbox-20

    2  Pages

Archived catalogs