Catalog excerpts
QuantaDat / nSens QuantaDat Multisensor-Transmitter This modular designed transmitter ,with multi sensor technology, is used as a display and signal output unit with 4 sensor channels and 4 analogue outputs. This allows the management of 4 measurement points by only 1 transmitter. The sensor identification is made automatically and the channels can be assigned and configured using the onboard menu. The integral climatic processor (Mollier chart) enables display and output of values such as dew point temperature, absolute humidity, specific enthalpy, mixing ratio etc. An RS-485 interface is integrated as standard. Bus interfaces and relay switches can be assembled with modular configuration. Technical data nSens-xx probes An integral component of the system is the digital nSens-HT humidity/temperature and nSens-T temperature sensor which works is over the whole measurement range with high accuracy and linear response characteristics . The calibration data is stored direct onto the sensor. The verification/calibration is performed by PC using the nSoft-CAL software. These plug-in probes are quickly replaced on site and the newly calibrated system may be put back into use again quickly, maintaining highest accuracy. Technical data Applications: • Monitoring and control of climatic processes in clean rooms, climatic chambers, mini-environments etc. • Climatic control in paper- and textile productions • Climatic monitoring and control in laboratories, calibration rooms etc. • Optimisation of combustion processes in gas turbines • Monitoring and control of climatic parameters in storages, server rooms and many more...
Open the catalog to page 1QuantaDat Multisensor Transmitter QuantaDat Set Multisensor capable transmitter system with 24V AC/DC power supply. Plastic housing blue/grey with IP 54 protection class. Standard set contains all parts for the installation (24VDC power supply must be provided) : - Transmitter unit QuantaDat - nSens cable with 5m of length - nSens-HT ENS sensor incl. filter cap - Including packaging Operation manual can be downloaded from www.novasina.ch (PDF document) Power supply: 24V +/- 15% AC/DC Version: QuantaDat-RL with parameters: -Water vap. partial pressure -Dew point temp. -Specific...
Open the catalog to page 2nSens-VAL-HT simulator Simulation-plug for the output of fixed values for relative humidity and temperature. The setting of the fixed values is done with the separately available nSoft-CAL calibration software. Simulators are used for checking and validation of climatic installations. In order to avoid any mix-up, the nSens-VAL-HT simulator disposes of a red coloured plug tip. Detailed information can be found in the technical data sheet. Communication: digital by Bus-system Value setting: with nSoft-CAL software nSens-HT-ENS renewed probe (with factory calibration certificate) Renewed...
Open the catalog to page 3Humidity generators SAL-SC (with factory calibration certificate) Reusable humidity standards based on saturated salt solutions in plastic cylinders with moisture permeable membranes. Each salt is delivered in a well-sealed box. Sensor Checks SC are obtainable for the following values (at 25°C) : 6.4 % rh 11.3 % rh 75.3 % rh Please consult the operation manual of your instrument to see which points can be calibrated. Other SAL-SC can be used for verification. The precision corresponds to the Greenspan Report 1977 typically +/- 0.3 % rh Weight : 90 g Humidity generators SAL-SC...
Open the catalog to page 490 ... 264VAC plugs EU/US/JP Secondary side: Voltage 24V DC +/- 5% Bared cable ends prepared for connection Weight: 90 gr Externa| power supply Primary side : voltage range External power supply with exchangeable plugs EU/US/JP Input : plug for standard sockets EU/US/JP (90..260VAC) Ouput : connection to QuantaDat transmitter (24VDC) nCap-P filter protection cap With dust protection filter insert. For optimal mechanical sensor protection as well as protection against dust. For particle sizes up to 10 pm. Housing material: PVDF black Filter insert: Polyethylene nCap-PS filter...
Open the catalog to page 5Dimension: - Wall clip Wall and duct mounting kit For probe fixation to walls and inside ducts. Fixation: - for wall mounting clip by fixing the bracket - for duct mounting flange by tightening the compression fitting The clip and the flange can be mounted with the delivered screws. Remark: The duct flange seals up to a pressure of 3 bar. Wall mounting kit with spacer For distance of 56 mm between wall and centre of probe. Recommended for probe mounting on temperature emitting walls. Including all mounting material. Dimension: - Wall clip Wall mounting kit Dimension:...
Open the catalog to page 6Applications: • Clean rooms • Isolators • Operating theaters • Labs, calibration rooms Industries: • Pharmaceutical • Life Science • Semiconductor • Hospitals • Pharmacies etc. nSens-... for BUS networks This adapter system allows a protocol transformation and hence nSens probes can be easily integrated in new and existing bus networks (Modbus). The operator benefits from a simple and fast integration in combination with the high measurement accuracy and linearity of the nSens sensors. This solution offers a cost efficient alternative to the use of transmitter systems with analogue output...