Catalog excerpts
Applications: • Clean rooms • Isolators • Operating theaters • Labs, calibration rooms Industries: • Pharmaceutical • Life Science • Semiconductor • Hospitals • Pharmacies etc. nSens-... for BUS networks This adapter system allows a protocol transformation and hence nSens probes can be easily integrated in new and existing bus networks (Modbus). The operator benefits from a simple and fast integration in combination with the high measurement accuracy and linearity of the nSens sensors. This solution offers a cost efficient alternative to the use of transmitter systems with analogue output signals. Your advantages: • Fully integration of measurement points in the network • Reliable digital signal transmission • Simple to install thank to small dimensions • Probe can be replaced fast and easy thanks to the with connection system • High measurement accuracy and linearity • Cost efficient and flexible solution • Simple and fast to verify and calibrate the measuring probes for direct integration in a Modbus network nSens-HT-ENS and nSens-T-NBS probe Digital nSens-HT humidity & temperature probe with resistive-electrolytic humidity- and NTC temp. sensor. With nCap-PS protection filter cap. Digital nSens-T temperature probe with high quality NTC temperature sensing element and nCap-E protection cap. The calibration points are saved directly on the probe. The verification and calibration is done by the separately available nSoft-CAL calibration software. The plug-in probe can be replaced very easily. Probes delivered in a separate package. Detailed information can be found in the technical data sheet. Communication: digital by Bus-system Fact. calibration: (nSens-T) Fact. calibration: (nSens-HT) Verification & Calibration: with nSoft-CAL at 2 temperature points incl. certificate at 5 humidity points incl. certificate nLink-Modbus adapter for nSens (HT/T) Signal conversion adapter from nSens probes to Modbus. Remark: each nSens probe requires 1 nLink-Modbus for connection. Dimensions: Weight: Connector: 20 x 60 mm approx. 30 g 5 pole screwed for Modbus and 3 pole for nSens Modbus-cable - length 2m For connection of a nLink-Modbus adapater to a Modbus network • Adapter-side with M12/4 connector • Network-side with open cable head Cable length: Weight: Connector: 005534.00 01.01.2017 Climatic Process measurement instruments - 2017&nbs
Open the catalog to page 1All Novasina AGnsens-ht-eis catalogs and technical brochures
-
LABTOUCH-AW
1 Pages
-
NSENS / NLINK-MODBUS
1 Pages
-
Catalogue_Climate_2019_EN
35 Pages
-
LabMaster-aw neo
1 Pages
-
Transmitter 2019
2 Pages
-
LABSTART-AW
1 Pages
-
CLIMMATE SET-AW
1 Pages