General Catalogue 2017 - Process measurement instruments
53Pages

{{requestButtons}}

Catalog excerpts

General Catalogue 2017 - Process measurement instruments - 1

Climatic measurement instruments Catalogue 2017 Pharmaceutical- & Semiconductor-industry Food industry Storages & Logistics

Open the catalog to page 1
General Catalogue 2017 - Process measurement instruments - 2

© Novasina AG, printed 2017 in Switzerland Technische Änderungen vorbehalten / Technical data subject to modification 005534.01 04.01.2017 Climatic Process measurement instruments - 2017

Open the catalog to page 2
General Catalogue 2017 - Process measurement instruments - 3

novasina The Art of Precision Measurement

Open the catalog to page 3
General Catalogue 2017 - Process measurement instruments - 4

Climatic Process measurement instruments - 2017

Open the catalog to page 4
General Catalogue 2017 - Process measurement instruments - 5

ClimMate / nSens-HTVersatile multi-parameter handheld device & data logger The ClimMate is a new, versatile handheld device for detection and storage of various parameters such as air humidity, temperature, absolute pressure, air speed, volumetric flow rate, CO2 as well as water activity and other calculated parameters. The user gets a complete solution, which is based on the unique high precision Novasina humidity measuring technology and which can be easily extended. The modern state-of-the-art operation and display unit excels with a big, colour LCD touch screen, an easy and intuitive...

Open the catalog to page 5
General Catalogue 2017 - Process measurement instruments - 6

Handheld device - ClimMate / nSens-HT nSens-HT / nSens-T nSenS-... probes Using the nLink-UMB adapter, various nSens probes can be connected to the ClimMate unit. The nSens probe range is continuously extended. But also probes and sensors from other suppliers can be used connecting them to the UMB-Bus interface. All Novasina nSens probes are intelligent, means the calibration points are stored directly on-board. The probe verification and calibration is done with a PC using the nSoft-CAL software. Applications: Moblie and precise measurement and monitoring of various measurement parameters...

Open the catalog to page 6
General Catalogue 2017 - Process measurement instruments - 7

Set handheld ClimMate & nSens-HT Set ClimMate with nSens-HT probe Consisting of: • Multifunction handheld instrument ClimMate • nSens-HT-ENS probe incl. nLink-UMB adapter • USB cable, length 1.8m • nSens extension cable, length 2m • 4 alkaline batteries LR6 AA, 1,5V • Humidity references SAL-SC 33% & 75%RH • Adapter SAL-SC for nSens probes • Factory calibration certificates • Short instruction manual • Carrying case for instrument, sensors and accessories • SmartGraph III software on CD Dimensions: Carrying case Instrument : • Dimensions : 170 x 62 x 34mm (ClimMate) • Weight: 205 gr...

Open the catalog to page 7
General Catalogue 2017 - Process measurement instruments - 8

Contains: - nSoft-CAL Software on CD - PDF Operating Manual on CD - nLink-USB connection cable for nSens probes with cable lenght of 1,8m nSoft-CAL calibration kit Windows based software for the verification and calibration of nSens probes with the PC. Runs on Windows 98/2000/XP/Vista/Windows 7 and 8. Incl. nLink-USB connection cable with 1,8m cable length. respectively with: - 1 plug for nSens-HT / T / VAL probe - 1 USB adapter plug for PC Reusable humidity standards based on saturated salt solutions in plastic cylinders with moisture permeable membranes. Each salt is delivered in...

Open the catalog to page 8
General Catalogue 2017 - Process measurement instruments - 9

USB power supply to ClimMate Power supply with USB socket for ClimMate. If powered by this power supply, the internal AA batteries are only for backup in case of a power failure. Remark : 1,8m USB cable already included in ClimMate set Input power : 100...260V AC 50/60 Hz Output power : +5V DC USB 1200mA / 6W Housing: plastic ABS / IP40 260 1215 Digital capacitive probe TFF 20 Digital capacitive humidity/temp. probe Robust calibrated humidity/temperature probe with digital UMB interface for direct connection to „C//mMate“. Remark : This probe type does not require an nLink-UMB adapter....

Open the catalog to page 9
General Catalogue 2017 - Process measurement instruments - 10

Robust protection bag for storage and transporation of handheld device, probe and humidity calibration references SAL-SC. The bag can be carried on the shoulder or fixed to the belt. A Velcro fastener avoids the instrument to fall out of the bag. Weight : 185 g (empty) Material : fabrics cushioned, 2 lateral pockets for 2 pcs SAL-SC Spare parts / options Replacement instrument ClimMate Single instrument without any accessories as spare part to set ClimMate. With capacitive Touch-LCD 320 x 240 dot display, internal datalogger memory and atm. pressure sensor. Power supply by USB or 4 x...

Open the catalog to page 10
General Catalogue 2017 - Process measurement instruments - 11

Spare parts to ClimMate & nSens-HT Contains: nLink-USB Adapter with 1,8m cable for connection of nSens c0nnecti0n cable for probes. nSens probes with cable length of 1,8m respectively with: - 1 plug for nSens-HT / nSens-T probe - 1 USB adapter plug for PC nCap-P filter protection cap Dimension: 012.6mm x L36.1mm With dust pr°tection fiiter misert. Housing material: PVDF black For optimal mechanical sensor protection as well as . Filter insert: Polyethylene protection against dust. For particle sizes up to 10 ^m. Housing material: PVDF black Filter...

Open the catalog to page 11
General Catalogue 2017 - Process measurement instruments - 12

Climatic Process measurement instruments - 2017

Open the catalog to page 12
General Catalogue 2017 - Process measurement instruments - 13

QuantaDat / nSens Multisensor-System QuantaDat / nSens QuantaDat Multisensor-Transmitter This modular designed transmitter ,with multi sensor technology, is used as a display and signal output unit with 4 sensor channels and 4 analogue outputs. This allows the management of 4 measurement points by only 1 transmitter. The sensor identification is made automatically and the channels can be assigned and configured using the onboard menu. The integral climatic processor (Mollier chart) enables display and output of values such as dew point temperature, absolute humidity, specific enthalpy,...

Open the catalog to page 13
General Catalogue 2017 - Process measurement instruments - 14

QuantaDat Multisensor Transmitter QuantaDat Set Multisensor capable transmitter system with 24V AC/DC power supply. Plastic housing blue/grey with IP 54 protection class. Standard set contains all parts for the installation (24VDC power supply must be provided) : - Transmitter unit QuantaDat - nSens cable with 5m of length - nSens-HT ENS sensor incl. filter cap - Including packaging Operation manual can be downloaded from www.novasina.ch (PDF document) Dimension: Power supply: Power consumption: Outputs: W150xH165xD54mm 24V +/- 15% AC/DC max. 3 W DC max. 3.0 W 4 x analogue U/I 0...10V /...

Open the catalog to page 14
General Catalogue 2017 - Process measurement instruments - 15

QuantaDat / nSens Multisensor-System nSens-VAL-HT simulator Simulation-plug for the output of fixed values for relative humidity and temperature. The setting of the fixed values is done with the separately available nSoft-CAL calibration software. Simulators are used for checking and validation of climatic installations. In order to avoid any mix-up, the nSens-VAL-HT simulator disposes of a red coloured plug tip. Detailed information can be found in the technical data sheet. Communication: digital by Bus-system Value setting: with nSoft-CAL software nSens-HT-ENS renewed probe (with...

Open the catalog to page 15