Catalogue 2017 - Datalogger series Hygro/Data/ClimaLog
6Pages

{{requestButtons}}

Catalog excerpts

Catalogue 2017 - Datalogger series Hygro/Data/ClimaLog - 1

HygroGuard 30ClimaLog30/DataLog 30 This new data logger series excel with useful functions and high versatility. As stand-alone devices or integrated in PC-networks the HygroGuard 30, ClimaLog 30 and DataLog 30 can be used in various applications for climatic data measurement and recording. The high storage capacity of 3'2 Mio data points and the AA batteries with >1 year of operation life make this data logger system ideal for many applications. The data visualisation and device configuration is done by the Windows software SmartGraph III which is included in the delivery. Novasina data logging product range: HygroGuard 30 with internal sensors for humidity and temperature ClimaLog 30 with internal sensors for humidity, temperature and with no internal sensors ready for 10 signals for monitoring systems. Data transmission is done via a UMB-Bus interface for the ..Maxx series or 2 x 4..20 mA. (e.g. 4 x StatMaxx + 2 PascalMaxx) Features: • High data storage capacity / large format LCD / flexible display • USB & Ethernet interface (TCP/IP) • connectable with external sensors via UMB bus for monitoring networks • versatile and intuitive software for data analysis Measuring range Accuracy Resolution Data logger systems: Dimensions : 166x78x32 mm Power supply : 4 x LRG AA Mignon batteries, USB - life time > 1 year Housing/protection : plastic ABS / IP40 Data storage : 16 MB, 3'200'000 measured values Interface : USB, LAN (Ethernet) Humidity measurement: Capacitive measurement principle Temperature measurement: NTC measurement principle Applications: • HVAC installations, clean rooms, calibration and QA laboratories • Museums, archives, libraries, storage rooms • Building Management Systems and monitoring systems • Pharmaceutical- chemical-, biotechnology, food-industry Air pressure measurement: Measuring range : 300...1300hPa abs. Accuracy : +/- 0.5hPa Climatic Process measurement instruments - 2017

Open the catalog to page 1
Catalogue 2017 - Datalogger series Hygro/Data/ClimaLog - 2

HygroGuard 30 / CimaLog 30 / DataLog 30 HygroGuard 30 Data logger system Battery powered data logger for recording of humidity, temperature/dew point with 16 MB data storage (3'200'000 values) with visualisation and configuration software and big LC-Display 90 x 64 mm. Delivery includes: - HygroGuard 30 device incl. 4 batteries - 1,8m USB data transfer cable - SmartGraph III software (on included CD) - Operation manual (on the CD) - Novasina factory calibration certificate Dimensions: 166x78x32 mm Weight: 250 g Power supply: 4 x LRG AA Mignon batteries (life time > 1...

Open the catalog to page 2
Catalogue 2017 - Datalogger series Hygro/Data/ClimaLog - 3

ClimaLog 30 DAkkS calibration Calibration certificate according to the official DAkkS accredited procedure. Calibration at 3 RH points, 1 temperature point and 5 absolute pressure points. DAkkS calibration including official certificate Calibration points: Rel.humidity : 20%, 50%, 80%rh at 20°C Temperature : 20°C Abs. pressure : 5 points in range 750 ...1200 mbar USB power supply Power supply with USB socket to power HygroGuard 30 ClimaLog 30 or DataLog 30. If powered by this unit, the internal AA batteries are only for backup and in case of a power failure. 1,8m USB cable already included...

Open the catalog to page 3
Catalogue 2017 - Datalogger series Hygro/Data/ClimaLog - 4

novasina The Art of Precision Measurement Theft protection kit (with lock) for HygroGuard 30, ClimaLog 30, DataLog 30 For all loggers. Can also be used as robust and safe wall mounting kit. Kit made of massive metal and can be secured with padlock. 260 1230 Theft protection Duct mounting kit Duct mounting flange for StatMaxx R. For easy and tight mounting to ducts or through walls/ceilings incl. sealing O-ring.Installation with 3 screws.The 13mm tight flange hole resists an overpressure of 3 bars. Sensor can be removed at any time for adjustment. -> Diameter fixation range: diam. 10 ...14...

Open the catalog to page 4
Catalogue 2017 - Datalogger series Hygro/Data/ClimaLog - 5

Bus cable Sensor-/actuator-cable, 4-pole, PUR, grey-black RAL 7021, straight connector M12, A-coded, on straight connector M12, A-coded Cable length: 10m respectively 2m. Cable lengths: Weight: Connector: UMB-Bus length: Y-junction 5-pole, connector straight M12 screw connections, A-coded, on straight connector M12, A-coded and straight connector M12, A-coded, parallel junction T-junction 5-pole, connector straight M12 screw connections, A-coded, on straight connector M12, A-coded and straight connector M12, A-coded, parallel junction

Open the catalog to page 5
Catalogue 2017 - Datalogger series Hygro/Data/ClimaLog - 6

Installation example 1(StatMaxx / PascalMaxx) 2x0..10V/4...20mA 1 x HygroMaxx R/S/M 2 x PascalMaxx 2 x Pascal STx 2 x TempMaxx 2 x PT 100 4 wire Hr- RJ 45 Ethernet TCP/IP connection to an data PC with Windows XP/7 and SmartGraph III LOG-PU BOX for StatMaxx and DataLog 30 Installation example 2(nSens-HT with nLink-UMB) UMB network node Monitoring System with DataLog 30 2 x analog inputs for other instruments Ethernet TCP/IP Climatic Process measurement instruments - 2017

Open the catalog to page 6

All Novasina AG catalogs and technical brochures

  1. LABTOUCH-AW

    1 Pages

  2. LABSTART-AW

    1 Pages