Overview: The Nova Model 436 Tri-Gas Analyzer is designed for monitoring hydrogen (H2) purity and purging in hydrogen-cooled power generators. It provides continuous analysis of H2 purity and purge monitoring for generators and synchronous converters.
Applications: The analyzer is used for continuous analysis of H2 purity and purge monitoring in hydrogen-cooled generators.
Features: The analyzer includes isolated 4-20mA output, low H2 purity alarms, automatic calibration, serial output with data-logging, and an oil vapor filter assembly. It offers a bright digital readout and fast response time (T90 - 10 to 15 seconds).
Calibration: The analyzer uses three channels for calibration: Channel 1 uses air for zero and 100% H2 for span; Channel 2 uses 100% CO2 for zero and 100% H2 for span; Channel 3 uses 100% CO2 for zero and air for span.
Specifications: The analyzer uses a temperature-controlled thermal conductivity cell for detection, with ranges of 0-100% H2 in Air, 0-100% H2 in CO2, and 0-100% Air in CO2. It has a resolution of ±0.1% of gas measured and accuracy within ±1% F.S. except in the 85-100% H2 in Air range, which is within 0.2% absolute H2. The response time is 10-15 seconds to 90% step change.
Models: The analyzer is available in different configurations: 436N4N7, 436RMN7, and 436N7MC, with options for explosion-proof cabinets and general-purpose cabinets.
Output and Alarms: The analyzer provides a 4-20 mA output for the 85-100% H2 in Air range, with optional outputs for other ranges. It includes dual alarms for low H2 purity and detector failure, with adjustable set points.
Contact Information: Nova Analytical Systems is located in Niagara Falls, NY, USA, and Hamilton, ON, Canada. Contact details include phone numbers and email addresses for sales inquiries.
See more

Catalog excerpts

Nova 436 Continuous Hydrogen Analyzer-1

436 SERIES TRI-GAS ANALYZER FOR MONITORING PURITY AND PURGING OF HYDROGEN COOLED POWER GENERATORS APPLICATIONS For continuous analysis of hydrogen (H2) purity and for purge monitoring of hydrogen-cooled generators and synchronous converters. FEATURES • One analyzer monitors all 3 gases for purity (Range 1) or purging (Ranges 2 and 3): • Range 1: 0-100% H2 in Air • Range 2: 0-100% H2 in CO2 • Range 3: 0-100% Air in CO2 • Bright digital readout • 4-20 mA isolated output for 85-100% of H2 in Air • Thermal-conductivity cell with high accuracy and repeatability, cannot be burned out. • Explosion-proof gas detector enclosure suitable for Class 1 Division 1 Group BCD rated areas • Fast response (T90 -10 to 15 secs) • Built in pressure regulator OPTIONS • Isolated 4-20mA output for any range selected • 2 levels of low H2 purity alarms & detector fail alarm • Automatic Calibration by microprocessor control available on N7MC configuration • Serial output with data-logging software • Oil vapor filter assembly NEMA 7 Gas Detector Cabinet Choice of Control Cabinet as follows: NEMA 4 Control Cabinet 19" Rack Mount Control Cabinet NEMA 7 Control Cabinet CALIBRATION • Channel 1 - Air for Zero, 100% H2 for Span • Channel 2 - 100% CO2 for Zero, 100% H2 for Span • Channel 3 - 100% CO2 for Zero, Air for Span NOVA ANALYTICAL SYSTEMS www.nova-gas.com Oil Vapor Filter Assembly - protects analyzer from sensor fouling caused by oil-vapors from power generator

 Open the catalog to page 1
Nova 436 Continuous Hydrogen Analyzer-2

DESCRIPTION The Nova Model 436RMN7 Tri-gas analyzer is designed specifically for monitoring H2 purity in a power generator and to monitor the purging procedure during shut down. The analyzer can measure the following gases by switch selection: Range 1: 0-100.0% H2 in Air; Range 2: 0-100.0% H2 in CO2; Range 3: 0-100.0% Air in CO2. An isolated 4-20 mA recorder output is provided for the range of 85-100% H2 in Air. The Model 436 analyzer is typically divided into 2 sections which are electrically connected. The control section contains the main microprocessor board as well as the digital readout...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.