8000 Series, Blast Furnace Top Gas Analyzer
3Pages

{{requestButtons}}

Catalog excerpts

8000 Series, Blast Furnace Top Gas Analyzer - 1

8000 SERIES BLAST FURNACE TOP GAS ANALYZER Applications Designed for the continuous monitoring of O2, CO, CO2, and/or H2 gases from blast furnaces or other continuous industrial processes where an uninterrupted stream of gas concentration data is critical. Calculated values of BTU, N2 and efficiency are also available. Description The Nova 8000 series has been designed for the continuous monitoring of pre-cleaned gases from a blast furnace or other high intensity, continuous industrial processes. The analyzer measures up to four gases simultaneously - O2, CO, CO2, and H2, the ranges of which are shown below. From these readings, other operating parameters such as nitrogen content, BTU and efficiency can be calculated and displayed. The analyzer consists of three main components: a heated filter cabinet which is directly mounted on the side of the blast furnace gas main, a sample conditioning system which is integral to the main analyzer cabinet, and the gas analysis sensors which are mounted in a separate but integral rack mount drawer, which eases service and maintenance. 7240 Heated Stack Sample Filter • 8002 - CO and CO2 • 8003 - H2, CO, and CO2 with H2 compensation • 8004 - H2, O2, CO, and CO2 with H2 compensation • 8006 - 8004 gases + N2, BTU and efficiency calculation • Other gases can be included as part of this platform, including CH4, SO2, NO, and NO2 in % or PPM ranges. Options • Cabinet purge system for use in dusty or hazardous locations • Cold weather package for operation to -5°F (-20°C) • Cabinet coolers can be fitted to most models 8000 Series Blast Furnace Top Gas Analyzer

Open the catalog to page 1
8000 Series, Blast Furnace Top Gas Analyzer - 2

8000 SERIES BLAST FURNACE TOP GAS ANALYZER Sample Conditioning • High capacity sample pump (where sample motivation is required) and high flow by-pass improves overall system response time • Compression-style moisture removal eliminates use of failure-prone pelletier elements • Redundant heated filters allow user to remotely switch from a blocked filter to an unblocked filter, minimizing down time due to filter blockage. • Automatic blow back of heated filter and probe, can be sequenced with autocalibration, or based on sample vacuum limit • Digital control maintains constant sample flow...

Open the catalog to page 2
8000 Series, Blast Furnace Top Gas Analyzer - 3

8000 SERIES BLAST FURNACE TOP GAS ANALYZER Nova reserves the right to specification changes which may occur with advances in design without prior notice. SPECIFICATIONS Description Method of Detection: O2 - customer replaceable electrochemical 'fuel cell' sensor CO/CO2 - dual channel, high accuracy NDIR infra-red detector H2 - thermal conductivity sensor N2 - continuously calculated by subtraction of other gases from 100% BTU - continuously calculated from the two flammable gases in the mixture Ranges Available: Oxygen - 0-5.0% Hydrogen - 0-10.0% and 0-20.0% Carbon Monoxide (CO) - 0-50.0%...

Open the catalog to page 3

All Nova Analytical Systems catalogs and technical brochures

  1. 337 series

    2 Pages

  2. 575 series

    2 Pages

  3. 4000 series

    2 Pages

  4. 481 series

    2 Pages

  5. 480 series

    2 Pages

  6. 362 Series

    2 Pages

  7. 376 Series

    2 Pages

  8. 381 Series

    2 Pages

  9. 382 Series

    2 Pages

  10. 425 Series

    2 Pages

  11. 436 Series

    2 Pages

  12. 7900 Series

    2 Pages

  13. 7900P Series

    2 Pages

  14. 309 Series

    2 Pages

  15. 352 Series

    2 Pages

  16. 501 Series

    2 Pages

  17. 5000 Series

    2 Pages

  18. 375 Series

    2 Pages

  19. 7200-2

    2 Pages

  20. Model 312WP

    2 Pages

  21. Model 425N4

    2 Pages

  22. 596 series

    2 Pages

  23. 309A series

    2 Pages

  24. 302A series

    2 Pages

  25. 402AS

    2 Pages

  26. 423 series

    2 Pages