Overview: The 628 Series Intrinsically Safe Hammer Union Pressure Transmitters are designed for hazardous locations, offering pressure ranges from 0 psig to 20,000 psig. They feature a current output and are constructed with Inconel X-750 wetted parts. These transmitters are approved by the Canadian Standards Association and comply with NACE MR0175/ISO 15156 standards. Certifications from Factory Mutual, ATEX, and CE are pending.
Applications: These transmitters are suitable for various applications including acidizing, choke & kill manifold, fracturing & cementing, mud logging & mud pumps, oil field & offshore, and well head measurement.
Specifications:
  • Output Signal: 4 mA to 20 mA, 2-wire
  • Pressure Ranges: 0 psig to 5,000 psig through 0 psig to 20,000 psig
  • Accuracy: ±0.25% full scale (BFSL)
  • Stability: ≤ ±0.2% full scale for 1 year
  • Response Time: < 2 ms
  • Durability: > 10,000,000 full scale cycles
  • Temperature Ranges: Compensated 40 °F to 140 °F; Media, Ambient, and Storage -40 °F to 185 °F
  • Power Requirement: 10 Vdc to 28 Vdc
  • Proof Pressure: 1.5 times full scale (22,500 psi max)
  • Burst Pressure: 3 times full scale (22,500 psi max)
  • Material: Inconel X-750 for measuring element and connection; 316 stainless steel housing
  • Environmental Rating: IP67
  • Electromagnetic Rating: CE compliant to EMC norm EN 61326:1997/A1:1998
  • Electrical Protection: Reverse polarity, over-voltage, and short circuit protected
  • Shock and Vibration: 100 g's and 15 g's respectively according to IEC standards
  • Weight: Approximately 6 lb.
Ordering Information: The 628 Series offers various configurations for pressure ranges, accuracy, output signal, wiring code, process connections, and electrical connections. Options include a carrying handle and an electrical connector cage.
See more

Catalog excerpts

628 series-1

Hazardous Location Pressure Transmitters Intrinsically Safe Hammer Union 628 SERIES • Ranges from 0 psig to 5,000 psig through 0 psig to 20,000 psig • Current output • Inconel X-750 wetted parts • Canadian Standards Association approved • NACE MR0175/ISO 15156 compliant • Every sensor comes with a Certificate of Calibration • Certifications pending: • Factory Mutual • ATEX • CE SPECIFICATIONS APPLICATIONS ■■ Acidizing ■■ Choke & kill manifold ■■ Fracturing & cementing ■■ Mud logging & mud pumps ■■ Oil field & offshore ■■ Well head measurement Shown with optional Electrical Connector Cage NOSHOK 628 Series transmitters are Canadian Standards Association approved for use in hazardous location applications as follows: Intrinsically Safe Class I, DIV 1, Groups A,B,C,D, -40°C,Tamb<+85°C T4, Class II, DIV 1, Groups E,F,G, Class III, Class I, Zone 0 AEx/Ex ic IIC T4. Non-Incendive Class I, DIV 2, Groups A,B,C,D, -40°C,Tamb<+85°C T4, Class II, DIV 2, Groups F,G, Class III, Class I, Zone 2 AEx/Ex ic IIC T4. Output signal Pressure ranges Accuracy 4 mA to 20 mA, 2-wire 0 psig to 5,000 psig through 0 psig to 20,000 psig ±0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) Stability ≤ ±0.2% full scale for 1 year, non-accumulating Response time < 2 m/s Durability > 10,000,000 full scale cycles Temperature ranges Compensated 40 °F to 140 °F (5 °C to 60 °C) Zero effect is ±0.01% full scale/ °F Span effect is ±0.01% full scale/ °F Media -40 °F to 185 °F (-40 °C to 85 °C) Ambient -40 °F to 185 °F (-40 °C to 85 °C) Storage -40 °F to 185 °F (-40 °C to 85 °C) Power requirement* 10 Vdc to 28 Vdc Load limitations ≤ (VPower-10)/0.020 Amp Proof pressure 1.5 times full scale (22,500 psi maximum) Burst pressure 3 times full scale (22,500 psi maximum) Measuring element Inconel X-750 Connection Inconel X-750 Housing material 316 stainless steel Environmental rating IP67 depending upon electrical connection Electromagnetic rating CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection Electrical protection Reverse polarity, over-voltage and short circuit protected 100 g's according to IEC 60068-2-27 Shock Vibration Weight

 Open the catalog to page 1
628 series-2

ORDERING INFORMATION DIMENSIONS ORDERING INFORMATION SERIES PRESSURE RANGES ACCURACY OUTPUT SIGNAL WIRING CODE 1 ±0.25% full scale (BFSL) 1 4 mA to 20 mA, 2-wire A C D (See Wiring Code Schematics below) PROCESS CONNECTIONS ELECTRICAL CONNECTIONS 14 2” Wing union (#1502) 3 6-pin Bendix (MIL-C-26482) 36 Integral cable with gland CH Carrying Handle 44 4-pin (MIL-C-5015) EC Electrical Connector Cage Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. * H is the standard wiring code. WIRING CODE SCHEMATICS Pin A * H is the standard wiring code. Optional...

 Open the catalog to page 2

All NOSHOK catalogs and technical brochures

  1. 100 Series

    4  Pages

  2. 400 series

    2  Pages

  3. 810 series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.