Catalog excerpts
Product Data for sound level meters, microphones and sound calibrators • Frequency response calibration of microphones using electrostatic or acoustical method • Sensitivity calibration of microphones using the insert voltage method ensures a high degree of accuracy • Fast and accurate calibration of sound calibrators, pistonphones and associated barometers in accordance with IEC60942 • Sound level meter calibration in accordance with IEC61672, IEC60651, IEC60804, DIN45657, ANSIS1.4, ANSIS1.43 and BS7580 • Fast and accurate calibration of sound measuring instruments using three different interface modes; manual; semi-automated and fully automated • Test of fractional octave filters in accordance with IEC61260 and IEC225 • Full test report generated • Built-in self test features • Turnkey system including all accessories needed. The calibration system Nor1504A is capable of calibrating virtually any type of sound measuring instruments, sound calibrators and microphones in accordance with applicable national and international standards. The test system is operated by a MS-Windows bases PC controlling the signal generator, voltmeter, test unit and the device under test (DUT). The computer also reads the barometer, the hygrometer and the thermometer which all are included with the system in order to provide the required environmental data in a fast and accurate manner for the calibration reports. A calibration of a sound level meter is normally divided into two main parts: electrical calibration of the sound measuring instrument and calibration of the microphone. Eventually, an accompanying sound calibrator may be calibrated and used for an overall system check. The measured results are automatically logged and used for an automatic generation of a calibration certificate in MS-word format. If needed, the certificate may be edited by the operator. Automatic generation of reported values minimize the risk for errors generated by the operator.
Open the catalog to page 1Test ob Produc ject : Type er : : Seria l No.: Clien t: Calibration of Sound Calibrators • Sound level corrected for pressure, temperature and humidity • Short term stability expressed in dB (option) Calibration of Microphones • Sensitivity of the microphone as mV/Pa and dB rel.1V/Pa • Frequency response using an electrostatic actuator in the frequency range 20-200 000 Hz • Frequency response using an anechoic chamber in the frequency range 20-20kHz (option) • The microphone cartridge capacitance [pF] (option) • Acoustic low-frequency response down to 0,1 Hz (option). The expanded...
Open the catalog to page 2All Norsonic AS catalogs and technical brochures
-
Product Range Catalogue
36 Pages
-
Nor1216 /Nor1217
4 Pages
-
Nor1210A and Nor1210C
2 Pages
-
Nor1209
2 Pages
-
Nor1207 and Nor1207/BNC
2 Pages
-
Microphone Preamplifier
2 Pages
-
Microphone Cartridges
2 Pages
-
Nor1292
2 Pages
-
Nor1530 Compact NMT
4 Pages
-
Nor277 Tapping machine
2 Pages
-
Acoustic Camera
8 Pages
-
Audiometer-Calibration Kit
1 Pages
-
Measuring Noise
2 Pages
-
Nor131 & Nor132
8 Pages
-
Nor 121
12 Pages
-
Nor 140
20 Pages
-
noise at work Nor 130
2 Pages
-
Noise excitation for BA
8 Pages
-
Sound Calibrators
4 Pages
-
Microphone Cartridges
2 Pages
-
Nor 130
8 Pages
-
Nor850 Product Data English
8 Pages
-
Product Range Catalogue 2011
52 Pages