Nor850 Product Data English
8Pages

{{requestButtons}}

Catalog excerpts

Nor850 Product Data English - 1

Product Data PD 850 Ed.1 Rev.1 English 01.11 Distributed Multichannel System Nor850 Norsonic is introducing a new concept in multichannel measurements; the Nor850 Distributed Multichannel System. By connecting a number of individual measuring units through various communication channels, the user may create the optimal multichannel system for any task. Dedicated user-friendly application packages for various uses are available, and the system control is done with a PC running the latest state-of-the-art Windows7 platform.

Open the catalog to page 1
Nor850 Product Data English - 2

PD 850 Ed.1 Rev.1 English 01.11 2 Expandable The multichannel system Nor850 may be expanded as the needs grow. At the time of introduction, Norsonic is offering two front end choices for the confi guration of the measuring channels in a multichannel system: - Nor140 Sound Level Meter - Nor850-MF1 mainframe containing 1-10 measuring channels Start with two units of the standardized Nor140 SLM’s and increase step-by-step by adding additional Nor140 units. Or, choose the multichannel Nor850-MF1 mainframe containing up to 10 measuring channels. The user may even set up a mix with a few Nor140...

Open the catalog to page 2
Nor850 Product Data English - 3

PD 850 Ed.1 Rev.1 English 01.11 3 Flexibility The concept of individual units for each measuring channel offers a very high degree of operating fl exibility. It allows the user to operate a multichannel system one day – and many individual measuring units another day! No need to store away an expensive multichannel system for months until the next big project turns up! This fl exibility is very well suited for building up a complete measurement system for larger laboratories with many measurement rooms. By placing one or more measurement channels in each measurement room, the full system...

Open the catalog to page 3
Nor850 Product Data English - 4

PD 850 Ed.1 Rev.1 English 01.11 4 Sensor database In the heart of the Nor850 software there is a sensor database containing all possible information about each customer complete list of measurement transducers (microphones, accelerometers, etc.), measuring channels, serial numbers, producers, calibration values, verification laboratories, verification dates, correction data, etc. By first time use the operator must key-in these data tom the system. Next time, however, as soon as any of the known transducers and measuring channels is connected, all data are automatically available within the...

Open the catalog to page 4
Nor850 Product Data English - 5

PD 850 Ed.1 Rev.1 English 01.11 5 Measurement setups The settings for the next measurement is done in the Measurement Menu which expands on the screen by a click on the Measurement tab. Within this menu, the operator sets the miscellaneous measurement parameters and functions. These include overall measurement duration, profile measurement resolution, filtering bandwidth, upper and lower frequency limitations, weighting networks, time constants, statistical percentiles, and finally the required measurement functions. Transducer calibration Prior to the measurement, each microphone or...

Open the catalog to page 5
Nor850 Product Data English - 6

PD 850 Ed.1 Rev.1 English 01.11 6 The application package for building acoustics is designed with two objectives in mind. Advanced laboratories with multiple test facilities require a system that offers great flexibility in the miscellaneous operational test tasks, including rapid setup of previous test procedures and the ability to use sophisticated measurement techniques. And yet the measurement system should be easy and efficient to use for the operators in order to produce test reports at the lowest possible number of man hours. Preset measurement Standards The system is delivered with...

Open the catalog to page 6
Nor850 Product Data English - 7

PD 850 Ed.1 Rev.1 English 01.11 7 Intelligent measurement control The screen will show the operator all the vital data at any time during the sound insulation test. Simply start by dragging the available measurement channels into the Source- or Receivewindow. Then the system knows which measurement channels that deliver source-room results and which channels that deliver receiving-room results. The operator may even alternate channels between the two measurement rooms during the test without any undesired mix of measurement results! Before each individual measurement, the operator should...

Open the catalog to page 7
Nor850 Product Data English - 8

PD 850 Ed.1 Rev.1 English 09.10 P.O.Box 24, N-3421 Lierskogen, Norway Tel.: +47 3285 8900 Fax.: +47 3285 2208 info@norsonic.com www.norsonic.com Distributor: Detailed measurement report The final measurement report as required in the measurement Standards (ISO-717 a.o.) is viewed as a separate window. Hence, details about the measurement object, conditions, project numbers, etc. may easily be edited by the operator. The report may be printed out on a color printer or send to the client as a .pdf document.

Open the catalog to page 8

All Norsonic AS catalogs and technical brochures

  1. Nor1209

    2 Pages

  2. Nor1292

    2 Pages

  3. Nor 121

    12 Pages

  4. Nor 140

    20 Pages

  5. Nor 130

    8 Pages