Catalog excerpts
Product Data PD Mics Ed.3 Rev.0 English 03.11 Microphone Cartridges Norsonic’s range of microphones covers most application and can be used as direct replacement with other brands. Full use has been made of modern materials which when coupled with traditional engineering skills produces microphones that meet all the requirements of the precision measurement standards yet are robust and resistant to corrosion. These microphones are used in conjunction with the Norsonic range of preamplifiers that closely couple to them and ensure perfect matching to the associated instrument with minimum disturbance to the acoustic field. The preamplifiers have the necessary signal handling capability and low self noise to allow full use to be made of the wide dynamic range of the microphones. Calibration Calibration of all Norsonic microphones is directly traceable to National and International Standards with particular attention being paid in the design to ensuring long term stability. Each microphone is delivered with an individual certificate of calibration giving all the key information relating to its performance. This includes the nominal sensitivity and frequency response along with the environmental data that relates to the calibration. Norsonic Calibration Laboratory is an international accreditated laboratory. This ensures that the quality of the measured values are at the highest possible level. Free-Field Microphones All Norsonic microphones are freefield types. A free-field microphone is designed to measure the sound pressure in the sound field, compensating for the influence of the presence of the microphone in the sound field. In effect, the microphone measures the sound pressure as it existed before the microphone was introduced in the sound field, i.e. free-field conditions. Applicable standard is IEC 61672 and the former IEC 60651. The freefield microphone should be pointed towards the sound source at a 0° angle of incidence. The key components that determines the accuracy of a sound level meter is the measurement microphone and its associated preamplifier. The effectiveness of these components in converting the acoustic signal into an electrical analogue set the maximum accuracy that can be achieved by the ensuing signal processing. Norsonic have a carefully balanced range of measurement microphones to suite a range of applications that complement modern instrumentation yet maintain traditional values.
Open the catalog to page 1PD Mics Ed.3 Rev.0 English 03.11 Distributor: P.O.Box 24, N-3421 Lierskogen, Norway Tel.: +47 3285 8900 Fax.: +47 3285 2208 info@norsonic.com www.norsonic.com Nor1229 is a ½” free-field, high sensitivity, low cost selfpolarised Class 2 microphone. Ideal for use in multi channels systems or other applications that requires a self polarised microphone at low cost with Class 2 accuracy. Unlike most other low cost Class 2 microphones it features a nickel membrane and a stainless steel housing, ensuring low sensitivity to environmental parameters such as temperature, static pressure and...
Open the catalog to page 2All Norsonic AS catalogs and technical brochures
-
Product Range Catalogue
36 Pages
-
Nor1216 /Nor1217
4 Pages
-
Nor1210A and Nor1210C
2 Pages
-
Nor1209
2 Pages
-
Nor1207 and Nor1207/BNC
2 Pages
-
Microphone Preamplifier
2 Pages
-
Microphone Cartridges
2 Pages
-
Nor1292
2 Pages
-
Nor1530 Compact NMT
4 Pages
-
Nor277 Tapping machine
2 Pages
-
Acoustic Camera
8 Pages
-
Audiometer-Calibration Kit
1 Pages
-
Measuring Noise
2 Pages
-
Nor131 & Nor132
8 Pages
-
Nor 121
12 Pages
-
Nor 140
20 Pages
-
noise at work Nor 130
2 Pages
-
Noise excitation for BA
8 Pages
-
Sound Calibrators
4 Pages
-
Nor 130
8 Pages
-
Nor850 Product Data English
8 Pages
-
Product Range Catalogue 2011
52 Pages