Catalog excerpts
Power Management Controller NORISYS 4 PMC - for Parallel Operation, Power Supply and System Protection The NORISYS 4 PMC - Power Management Controller - was deve- NORISYS 4 expansion unit, also used as an autarkic system loped as part of the NORISYS 4 control components in the auto- Optional expansion with NORISYS 4 modules mation platform. Optional connection of colour touch panel for observation and control purposes The power management unit is used as an independent control USB port for servicing purposes system with an optional colour touch panel and can be expan- RS-485 for NORISYS 4 ExtBus communication ded to form a high-level system with further components of the Generator set control with automatic start/stop function Parallel and isolated operation Automatic synchronisation Generator protection functions, 3-phase cessor with DSP functionality. In its basic version, the PMC is used Power supply protection function, 3-phase to switch generators to the power grid and is also suitable for use in stand-by power supply facilities. The system is designed to be used for isolated and parallel operation. An automatic start and synchronisation function is additionally implemented to accelerate the generator, set to nominal speed as well as to synchronise and close the power circuit breaker. The power requirements are defined by a higher-level system. An automatic facility that controls load balancing, opening of the power circuit breaker and stopping of the propulsion system is also integrated for the purpose of shutting down the generator. The Power Management Controller is equipped with an integrated power supply and system protection function.
Open the catalog to page 1Discrete Signals Discrete Signals Discrete Signals NORISYS 4 PMC - Inputs J3 x system voltage (up to 385 V AC) J3 x generator voltage (up to 385 V AC) J3 x generator current transformer up to 5A AC x speed pick-up J2 x analogue input (0 ... 20 mA, 4 ... 20 mA, 0 ... 10 V, +10 V ... -10 V) J1 x battery voltage (32 V) J1 x oxygen sensor voltage for system with mixture control J1 x potentiometer J10 x digital input, 1-pole NORISYS 4 PMC - Outputs J2 x analogue output (0 ... 20 mA, 4 ... 20 mA, 0 ... 5 V, +/-5 V, 0 ... 10 V, +/-10 V) J10 x digital output, 1-pole NORISYS 4 PMC - Communication...
Open the catalog to page 2All NORIS Group GmbH catalogs and technical brochures
-
data sheet FA54
11 Pages
-
Datasheet EOT
6 Pages
-
NORIS yacht brochure
16 Pages
-
Flyer myNORIS
3 Pages
-
Energy Storage System
2 Pages
-
NORIS Marine Overview
13 Pages
-
Flyer NORIMOS 4
3 Pages
-
Flyer N3500
3 Pages
-
Datasheet NORISPEED FMN6
2 Pages
-
Datasheet TAV131
6 Pages
-
Datasheet TA14
5 Pages
-
Datasheet TA17
5 Pages
-
Datasheet VFS5
2 Pages
-
Datasheet RTK5
2 Pages
-
Datasheet RI5
2 Pages
-
Datasheet RFJ5
2 Pages
-
Datasheet PAx9
6 Pages
-
Datasheet FA11
14 Pages
-
Datasheet VF5..-KD
2 Pages
-
Datenblatt VFS5
2 Pages
-
Datasheet VFW5
2 Pages
-
Datasheet NIR3 NIQ3
20 Pages
-
Flyer NORISYS 4 CPU
2 Pages
-
Datasheet RG5
2 Pages
-
Datasheet SIR3 SIQ3
10 Pages
-
Datasheet RFG5
2 Pages
-
Datasheet FA13
14 Pages
-
Datasheet NIQ3
20 Pages
-
Datasheet FAH52
14 Pages
-
Datasheet FAHZ53
7 Pages
-
Datasheet VP5
2 Pages
-
Datasheet RFW5
2 Pages
-
Datasheet RH41M
2 Pages
-
Datasheet RH5
2 Pages
-
Datasheet RF5
2 Pages
-
Datasheet RP5, RPT5
2 Pages
-
NORIYSY 4 Deep Sea
2 Pages
-
Flyer N3000-SAP
1 Pages
-
Datasheet
2 Pages
-
Datasheet DWA
4 Pages
-
Datasheet TA18
5 Pages
-
Datasheet VTK5
2 Pages
-
Datasheet GE1214
2 Pages
-
Datasheet GE12
2 Pages
-
Datasheet GZ121
2 Pages
-
Datasheet VPT5
2 Pages
-
Datasheet GE14
2 Pages
-
Datasheet NADS3
2 Pages
-
Datasheet NIQ31
16 Pages
-
Datasheet NAD1
2 Pages
-
Datasheet NAD2
2 Pages
-
NORIS Group GmbH Brochure en
13 Pages
-
NORIS Brochure
15 Pages
-
Datasheet TP31 TH31
5 Pages
-
Datasheet TP23
4 Pages
-
Datasheet VD61
6 Pages
-
Datasheet VF5
2 Pages
-
RW5
2 Pages
Archived catalogs
-
Speed sensor Type FAW
1 Pages
-
stepper motor principle
1 Pages
-
Combi-sensor Type KA
1 Pages
-
moving-coil element
1 Pages
-
Combi-sensor Type KA
1 Pages