Catalog excerpts
Measuring transducer for frequency, input NORIS standard signal 1 2 • Straightforward application • Galvanic isolation between sensor input and Umgeb. Amb. Temp Temp: : and operating voltage to the output signal Measuring Transducers • Suitable for severe operating conditions • Compact construction • Frequency ranges to suit customer requirements • Provision made for fine adjustment of measuring range • Anti-tamper seal for the fine adjustment • Meet high EMC-requirements • Short-circuit-proof output selectable from • Operating characteristics displayed by integrated LED • Flame-inhibiting and self-extinguishing body • Suitable speed sensors are available Measuring transducers of series 5 Measuring transducers of the Series 5 are designed to convert electric input values into standardised output signals. Principle of operation: The transducer signal measured at the converter input is converted into a standardised output signal that is proportional to the input and lends itself to further customised processing, for instance, in a machine controller. General notes on Type VF5.. Description VF5.. • Signal input for a NORIS standard frequency signal Input signal The NORIS standard signal corresponds to a rectangular voltage with • Suitable to evaluate sensors of the FT.. and FA.. series an amplitude that corresponds to • Input range: 0 ... 10.000 Hz (according to type) the operating voltage applied. This • Maximum range frequency between: 50 ... 100 Hz (VF500..), results in a signal that is immune to interference and tolerates consider- (Factory-set frequency adjustment) able changes in the operating volt- To avoid triggering errors the frequency full range set in factory must be the highest frequency of the measuring chaine. age. The operating voltage required by the sensor is provided by the measuring transducer. Electric isolation The operating voltage and sensor input are electrically isolated from the output signal. Therefore, multiple operation of amplifiers and evaluation devices is possible at the same operating voltage and from only one sensor. Operating status display by LED The green LED will be lit when the operating voltage is applied and the device is working normally. Output signal The output signal generated is a standardized voltage of 0 ... 10 V/DC or 2 ... 10 V/DC or, respectively, a standardized current of 0 ... 20 mA or 4 ... 20 mA. The output signal follows the input signal strictly linearly (deviation < 0.1%). The output signal can be used to supply additional devices, such as indicating instruments and limit-value switches. Attention should be paid to the maximum driver ca
Open the catalog to page 1Other Data Type key / variants LED code x = LED lighting - = LED out o= LED flashing OPerating x Frequency version: Please state upper range frequency in case of order Device codes (10 V/DC or 20 mA meets the ordered input frequency) - ... Maximum range frequency in Hz (= 20 mA or 10 V) Measuring transducer Input signal F Frequency input for NORIS standard signal (sensor series FT / FA) Type series 5 Type 5 Input range fB / upper-range frequency fE Maximum range frequency
Open the catalog to page 2All NORIS Group GmbH catalogs and technical brochures
-
data sheet FA54
11 Pages
-
Datasheet EOT
6 Pages
-
NORIS yacht brochure
16 Pages
-
Flyer myNORIS
3 Pages
-
Energy Storage System
2 Pages
-
NORIS Marine Overview
13 Pages
-
Flyer NORIMOS 4
3 Pages
-
Flyer N3500
3 Pages
-
Datasheet NORISPEED FMN6
2 Pages
-
Datasheet TAV131
6 Pages
-
Datasheet TA14
5 Pages
-
Datasheet TA17
5 Pages
-
Datasheet VFS5
2 Pages
-
Datasheet RTK5
2 Pages
-
Datasheet RI5
2 Pages
-
Datasheet RFJ5
2 Pages
-
Datasheet PAx9
6 Pages
-
Datasheet FA11
14 Pages
-
Datasheet VF5..-KD
2 Pages
-
Datenblatt VFS5
2 Pages
-
Datasheet VFW5
2 Pages
-
Datasheet NIR3 NIQ3
20 Pages
-
Flyer NORISYS 4 CPU
2 Pages
-
Datasheet RG5
2 Pages
-
Datasheet SIR3 SIQ3
10 Pages
-
Datasheet RFG5
2 Pages
-
Datasheet FA13
14 Pages
-
Datasheet NIQ3
20 Pages
-
Datasheet FAH52
14 Pages
-
Datasheet FAHZ53
7 Pages
-
Datasheet VP5
2 Pages
-
Datasheet RFW5
2 Pages
-
Datasheet RH41M
2 Pages
-
Datasheet RH5
2 Pages
-
Datasheet RF5
2 Pages
-
Datasheet RP5, RPT5
2 Pages
-
NORIYSY 4 Deep Sea
2 Pages
-
Flyer N3000-SAP
1 Pages
-
Datasheet
2 Pages
-
Datasheet DWA
4 Pages
-
Datasheet TA18
5 Pages
-
Flyer NORISYS 4 PMC
2 Pages
-
Datasheet VTK5
2 Pages
-
Datasheet GE1214
2 Pages
-
Datasheet GE12
2 Pages
-
Datasheet GZ121
2 Pages
-
Datasheet VPT5
2 Pages
-
Datasheet GE14
2 Pages
-
Datasheet NADS3
2 Pages
-
Datasheet NIQ31
16 Pages
-
Datasheet NAD1
2 Pages
-
Datasheet NAD2
2 Pages
-
NORIS Group GmbH Brochure en
13 Pages
-
NORIS Brochure
15 Pages
-
Datasheet TP31 TH31
5 Pages
-
Datasheet TP23
4 Pages
-
Datasheet VD61
6 Pages
-
RW5
2 Pages
Archived catalogs
-
Speed sensor Type FAW
1 Pages
-
stepper motor principle
1 Pages
-
Combi-sensor Type KA
1 Pages
-
moving-coil element
1 Pages
-
Combi-sensor Type KA
1 Pages