Datasheet VF5..-KD
2Pages

{{requestButtons}}

Catalog excerpts

Datasheet VF5..-KD - 1

Measuring transducer, frequency type to correct for wheel/tyre wear on rail vehicles 1 2 Straightforward application Suitable for severe operating conditions Compact construction Tyre diameter setting by means of Nenn-Rad nominal tire reifen : dia: tamper-evident drum scale • For all commercial tyre diameters Umgeb. Amb. Temp Temp: : Measuring Transducers Galvanic isolation between sensor input and and operating voltage to the output signal Meet high EMC-requirements Short-circuit-proof output selectable from Operating characteristics displayed by integrated LED Flame-inhibiting and self-extinguishing body Suitable speed sensors are available (NORIS devices FA../ FT..) Measuring transducers of series 5 Measuring transducers of the Series 5 are designed to convert electric input values into standardised output signals. Principle of operation: The transducer signal measured at the converter input is converted into a standardised output signal that is proportional to the input and lends itself to further customised processing, for instance, in a machine controller. General notes on Type VF5xxKDx-x Description VF5..KD.-. The type VF5..KD.-. is designed to compensate signal output of the Output signal The output signal generated is a standardized voltage of speed sensor to allow for the diameter of the tyre, when worn. The correc- 0 ... 10 V/DC or 2 ... 10 V/DC or, respectively, a standardized current of ted signal output then reflects the true speed, whereas operational wear 0 ... 20 mA or 4 ... 20 mA. The output signal follows the input signal strictly and turning-down of the tread would result in high readings. linearly (deviation < 0.1%). The output signal can be used to supply additional devices, such as Details VF5..KD.-x. • Signal input for a NORIS standard frequency signal indicating instruments and limit-value switches. Attention should be paid to the maximum driver capability of the output. • Suitable to evaluate sensors of the FT.. and FA.. series • Setting of tyre diameter by means of drum scale directly in mm • Input range: 0 ... 10.000 Hz • The upper-range frequency is factory-adapted Input signal The NORIS standard signal corresponds to a rectangular voltage with an amplitude that corresponds to (corresponding to the maximum speed readings based on the the operating voltage applied. This diameter of the tyre when new) results in a signal that is immune to • Correction range to suit customer´s requirements interference and tolerates consider- To avoid triggering errors the frequency full range set in factory must be able changes in the operating volt- the highest frequency of the measuring chaine. age. The operating voltage required by the sensor is provided by the Electric isolation measuring transducer. The operating voltage and sensor input are electrically isolated from the output signal. Therefore, multiple operation of amplifiers and evaluation devices is possible at the same operating voltage and from only one sensor. Operating status display by LED The green LED will be lit when the operating voltage is applied and the dev

Open the catalog to page 1
Datasheet VF5..-KD - 2

Other Data LED code x = LED lighting - = LED out o= LED flashing OPerating x Type key / variants Frequency version: speed and tyre diameter to be stated in order. F Frequency input for NORIS standard signal (sensors series FT / FA) Input range fB / upper-range frequency fE 00 Tyre / Maximum speed type KDx KDx with facility to set tyre diameter x = code for tyre size as a function of maximum speed readings (defined at time of order)

Open the catalog to page 2

All NORIS Group GmbH catalogs and technical brochures

  1. Flyer N3500

    3 Pages

  2. Datasheet FA11

    14 Pages

  3. Datasheet FA13

    14 Pages

  4. Datasheet NIQ3

    20 Pages

  5. Datasheet

    2 Pages

  6. NORIS Brochure

    15 Pages

  7. RW5

    2 Pages

Archived catalogs