Temperature sensor TA14, Construction type 14, flange sensor, lateral 90° cable outlet NOR/S Measuring element/Measuring principle Application range Temperature sensors of the TA14 series are especially designed for use in Transport technology for temperature measurement in traction motors, gear boxes, wheelset bearings and compressor- and air conditioning systems. Measuring principle Temperature sensors of the TA14 series operate according to the measurement principle / with the measuring element Pt100/Pt1000 in 2-,3- oder 4-wire type. Functioning of platinum measuring elements With this measuring principle the temperature-sensitive resistance value of the measuring element is acquired. For platinum measuring elements the electrical resistance increases with increasing temperature and decreases with decreasing temperature (temperature linear). Advantages of platinum measuring elements are: • accurate and reproducible thermoelectric characteristics • nearly linear temperature characteristic • easy to replace (no calibration necessary, corresponding to international standards, e. g. IEC 751 / DIN EN 60751) • measurement is faster and more precise than with thermocouples Specific features • Compact, robust and closed design • Easy installation via flange mounting • Available in different immersion depths • Easy customisable sensor groups and cable assembly, optionally with insulation > 2kVAC • As 2-, 3- or 4-wire type available • Maintenance-free • Weight optimised design; also available with 45° cable outlet (see TA17) Datasheet DB-TA14-EN | V01.02 | 07/12/2016 | Valid from product revision Rev. C | www.noris-group.com | sales@noris-grou
Open the catalog to page 1| Dimensions, connections and drawings NORIS Automation GmbH Dimensions, connections and drawings Explanation to the illustration N: Nominal length 75 ±0.5 mm (other lengths on request) A: Length 16 mm B: Ø 5 ±0.05 mm C: Length 52.5 ±2 mm (with standard cable) E: Measuring tip nickel plated F: Stainless steel tube G: Sensor head aluminium anodised H: Bend protection Boreholes top view: C: Ø 5.2 H11 mm D: Length 6 mm E: Length 17 ±0.2 mm Cable with polyamide protective tubing Cable with special protective tubing Cable and protection hoses Cable standard (without protective tubing) A: Length...
Open the catalog to page 2NORIS Automation GmbH Dimensions, connections and drawings | Connections Standard connection is a cable end (see next Fig.). Other customised connections (e. g. plug connectors, terminal box, etc.) are available on request. Also available combined with other sensors in one sensor group (cable harness for temperature and/or speed). Cable end Explanation to the illustration A: wire length 80 ±10 mm NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 3| Technical Data NORIS Automation GmbH DB-TA14 NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 4NORIS Automation GmbH Type code | Type code structure Measuring principle / Measuring elements Number of measuring elements Construction type Nominal length N (immersion depth) Sensor tube diameter Electrical connection Cable length Wire type design Shielding Type code type TA14 Measuring principle/ Measuring elements Number of measuring elements Construction type Nominal length N (immersion depth) Sensor tube diameter One measuring element Two measuring elements Flange sensor, lateral 90° cable outlet Flange sensor, lateral 90° cable outlet, increased insulation resistance 75 mm 100 mm...
Open the catalog to page 5All NORIS Group GmbH catalogs and technical brochures
-
data sheet FA54
11 Pages
-
Datasheet EOT
6 Pages
-
NORIS yacht brochure
16 Pages
-
Flyer myNORIS
3 Pages
-
Energy Storage System
2 Pages
-
NORIS Marine Overview
13 Pages
-
Flyer NORIMOS 4
3 Pages
-
Flyer N3500
3 Pages
-
Datasheet NORISPEED FMN6
2 Pages
-
Datasheet TAV131
6 Pages
-
Datasheet TA17
5 Pages
-
Datasheet VFS5
2 Pages
-
Datasheet RTK5
2 Pages
-
Datasheet RI5
2 Pages
-
Datasheet RFJ5
2 Pages
-
Datasheet PAx9
6 Pages
-
Datasheet FA11
14 Pages
-
Datasheet VF5..-KD
2 Pages
-
Datenblatt VFS5
2 Pages
-
Datasheet VFW5
2 Pages
-
Datasheet NIR3 NIQ3
20 Pages
-
Flyer NORISYS 4 CPU
2 Pages
-
Datasheet RG5
2 Pages
-
Datasheet SIR3 SIQ3
10 Pages
-
Datasheet RFG5
2 Pages
-
Datasheet FA13
14 Pages
-
Datasheet NIQ3
20 Pages
-
Datasheet FAH52
14 Pages
-
Datasheet FAHZ53
7 Pages
-
Datasheet VP5
2 Pages
-
Datasheet RFW5
2 Pages
-
Datasheet RH41M
2 Pages
-
Datasheet RH5
2 Pages
-
Datasheet RF5
2 Pages
-
Datasheet RP5, RPT5
2 Pages
-
NORIYSY 4 Deep Sea
2 Pages
-
Flyer N3000-SAP
1 Pages
-
Datasheet
2 Pages
-
Datasheet DWA
4 Pages
-
Datasheet TA18
5 Pages
-
Flyer NORISYS 4 PMC
2 Pages
-
Datasheet VTK5
2 Pages
-
Datasheet GE1214
2 Pages
-
Datasheet GE12
2 Pages
-
Datasheet GZ121
2 Pages
-
Datasheet VPT5
2 Pages
-
Datasheet GE14
2 Pages
-
Datasheet NADS3
2 Pages
-
Datasheet NIQ31
16 Pages
-
Datasheet NAD1
2 Pages
-
Datasheet NAD2
2 Pages
-
NORIS Group GmbH Brochure en
13 Pages
-
NORIS Brochure
15 Pages
-
Datasheet TP31 TH31
5 Pages
-
Datasheet TP23
4 Pages
-
Datasheet VD61
6 Pages
-
Datasheet VF5
2 Pages
-
RW5
2 Pages
Archived catalogs
-
Speed sensor Type FAW
1 Pages
-
stepper motor principle
1 Pages
-
Combi-sensor Type KA
1 Pages
-
moving-coil element
1 Pages
-
Combi-sensor Type KA
1 Pages