Catalog excerpts
Type NORIMETER 3 analogue indicator with stepper motor technology, universally applicable Construction type Scope of application NORIMETER 3 indicators are mainly used in the Shipbuilding industry, transport technology and mechanical engineering. The indicators fulfill the requirements of the DIN EN 50155 for railway technology and of common ship classification societies and thus, are suitable for applications in harsh environments. Thanks to the mechanical construction, the housing is highly resistant against salt spray and thus, outdoor use is possible. The DIN-compliant housing sizes are suitable for installation in control cabinets and control panels with pre-stamped standardised installation openings. Display principle The display on the NORIMETER 3 is via a high-resolution stepper motor with integrated precision transmission at a resolution of 12 steps per degree. A display with a 240° standard scale thus achieves a resolution of the measuring signal in 2880 display steps. The motor itself has a mechanical transmission end stop and an angle of rotation of 315°. This makes a scale angle of up to 300° possible. In addition, a display with a 360° rotating faceplate is available (see data sheet DB-NIQ31). The motor is controlled by the firmware via a digital filter. This results in an optimum combination of smooth adjustment of the measure value and high precision (without the pointer wavering). The transmission backlash is almost halved by the firmware. This measure allows a display accuracy greater than 0.5% to be achieved relative to the measuring range. Special features • Indicator with non-linear scales (spreading scale) available • Long lifetime due to compact and robust technology, a high protection class and a glass-fibre-reinforced, salt spray resistant plastic housing, suitable for outdoor areas • Individual scale design and corporate logos possible, even for small quantities • Option: Available as indicator with 360° rotary faceplate (see datasheet DB-NIQ31) or as indicator with frequency input with integrated direction-of-rotation monitoring • Option: Minimum-Maximum value indication for saving and indicating the highest and lowest measured value • Option: Control functionality for sensor failure and power supply failure (Live-Zero) • Connection for external illumination control as well as separate default brightness setting. On devices with an illuminated pointer it is also possible to set the pointer lighting separately. Datasheet DB-NIR3/NIQ3-EN | V01.05 | 25/02/2019 | Valid from product revision Rev.A | www.noris-group.com | sales@noris-group.com
Open the catalog to page 1| Content NORIS Automation GmbH Display versions [► 3] Standard equipment [► 4] IScale and pointer [► 4] Zero point, pointer return point and measuring range [► 6] iLighting [► 6] iLine compensation for temperature display [► 7] Monitoring functions [► 7] Optional special functions [► 8] I Signal LED and flashing pointer [► 8] Line compensation [► 8] IMin/max display [► 9] iLimit value switch output [► 9] Motor with anti-clockwise rotation [► 9] Measured quantities [► 10] Dimensioned drawing, connection diagrams and circuit diagrams [► 12] Technical data [► 15] Type code [► 17] Scale design...
Open the catalog to page 2NORIS Automation GmbH Indicator versions The following figures show the indicator types and sizes: Housing sizes for Type NIR3 with round design From left to right: Type NIR3 Ø 60 mm, Ø 80 mm, Ø 100 mm, Ø 130 mm Housing sizes for Type NIQ3 with square design From left to right: Type NIQ3 72x72 mm, 96x96 mm, 144x144 mm NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 3| Standard version NORIS Automation GmbH Standard version Scale and pointer The markings and the graduation of the scale are in accordance with DIN43802 and DIN43780 but can also be customer-specific on request. Coarse graduation With this graduation, defined graduation marks are thicker. This allows the values to be better read even at a higher distance. Orientation graduation With this graduation, all graduation marks are of equal width. DB-NIR3_NIQ3 NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 |...
Open the catalog to page 4NORIS Automation GmbH Standard version | NORIS Automation GmbH Standard version | Square design, Type NIQ3 Fig. 8 DB-NIR3_NIQ3 NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted
Open the catalog to page 5| Standard version NORIS Automation GmbH Scale zero point Scale zero point: customer-specific The position of the scale zero point can be specified as required. Scale zero point on the right iScale zero point in the middle (Standard) i(Standard) Return point Measuring range • When the power is off, the pointer turns to the return point. • The position can be specified as required. The return point must not be the zero point (e.g. to allow power failures to be detected in the live zero function) Note the difference between the printed measuring range on the scale (can be individually...
Open the catalog to page 6NORIS Automation GmbH Standard version | ATTENTION: Line compensation changes the factory setting. Incorrect line compensation can cause the reading to deviate from the actual measured values. It may then not be possible to detect when limit values are overshot or undershot. NORIS shall accept no liability for any damage which may be incurred as the result of incorrect line compensation. For indicators with PT100/PT1000-, NTC thermistor or resistance inputs, the optional function "Line Compensation" is implemented as standard. Thus, the indication can be adapted to probable existing signal...
Open the catalog to page 7| Optional special functions NORIS Automation GmbH Optional special functions Special functions can be integrated into NORIMETER 3 indicators upon customer request. Some functions can be combined. Note: Auxiliary functions that use the indicator's auxiliary port (AUX) cannot be combined. Note: Optional special functions are not covered by the ordering code in the type code and must be requested in the order text. Signal LED and flashing pointer Note: The functional principle required and the application (coupling) must be stated in the order and can then no longer be changed by the...
Open the catalog to page 8All NORIS Group GmbH catalogs and technical brochures
-
data sheet FA54
11 Pages
-
Datasheet EOT
6 Pages
-
NORIS yacht brochure
16 Pages
-
Flyer myNORIS
3 Pages
-
Energy Storage System
2 Pages
-
NORIS Marine Overview
13 Pages
-
Flyer NORIMOS 4
3 Pages
-
Flyer N3500
3 Pages
-
Datasheet NORISPEED FMN6
2 Pages
-
Datasheet TAV131
6 Pages
-
Datasheet TA14
5 Pages
-
Datasheet TA17
5 Pages
-
Datasheet VFS5
2 Pages
-
Datasheet RTK5
2 Pages
-
Datasheet RI5
2 Pages
-
Datasheet RFJ5
2 Pages
-
Datasheet PAx9
6 Pages
-
Datasheet FA11
14 Pages
-
Datasheet VF5..-KD
2 Pages
-
Datenblatt VFS5
2 Pages
-
Datasheet VFW5
2 Pages
-
Flyer NORISYS 4 CPU
2 Pages
-
Datasheet RG5
2 Pages
-
Datasheet SIR3 SIQ3
10 Pages
-
Datasheet RFG5
2 Pages
-
Datasheet FA13
14 Pages
-
Datasheet NIQ3
20 Pages
-
Datasheet FAH52
14 Pages
-
Datasheet FAHZ53
7 Pages
-
Datasheet VP5
2 Pages
-
Datasheet RFW5
2 Pages
-
Datasheet RH41M
2 Pages
-
Datasheet RH5
2 Pages
-
Datasheet RF5
2 Pages
-
Datasheet RP5, RPT5
2 Pages
-
NORIYSY 4 Deep Sea
2 Pages
-
Flyer N3000-SAP
1 Pages
-
Datasheet
2 Pages
-
Datasheet DWA
4 Pages
-
Datasheet TA18
5 Pages
-
Flyer NORISYS 4 PMC
2 Pages
-
Datasheet VTK5
2 Pages
-
Datasheet GE1214
2 Pages
-
Datasheet GE12
2 Pages
-
Datasheet GZ121
2 Pages
-
Datasheet VPT5
2 Pages
-
Datasheet GE14
2 Pages
-
Datasheet NADS3
2 Pages
-
Datasheet NIQ31
16 Pages
-
Datasheet NAD1
2 Pages
-
Datasheet NAD2
2 Pages
-
NORIS Group GmbH Brochure en
13 Pages
-
NORIS Brochure
15 Pages
-
Datasheet TP31 TH31
5 Pages
-
Datasheet TP23
4 Pages
-
Datasheet VD61
6 Pages
-
Datasheet VF5
2 Pages
-
RW5
2 Pages
Archived catalogs
-
Speed sensor Type FAW
1 Pages
-
stepper motor principle
1 Pages
-
Combi-sensor Type KA
1 Pages
-
moving-coil element
1 Pages
-
Combi-sensor Type KA
1 Pages